Tender For gc section:- repair work like desilting, epoxy grouting, flooring , inspection steps, chequered plate etc of various major bridges(i.e. bridge no.34a, 39, 42a, 71, 116, 150, 151, 160, 167, 187, 202, 332 & 416) in the jurisdiction of sr.den/2/dhn.
Tender For work of supply & application of nano-technology based acid and alkali resistant nano modified anticorrosivecoating on gantry and equipment support structure at various 220/132/110kv sub-station under ehv o&m dn., karad.
Tender For bid to ras est of hyd trg lab with integrated facility for hyd system - puf panel sheet, both side 0.40mm ppg sheet, colour white ral 9002, pud density: 04 kgm3, panel joint : overlapped, thickness 50mm with installation, aluminium sliding door (6 ft width x 7 ft height), aluminium section (1.2 mm thick black powder coated section) with 5 mm thick bakelite sheet and 5mm thick black semi-transparent glass (saint gobin), grid ceiling with 2'x2' grid distance, epoxy coating on floor & colour: blue, necessary electric point (wire: r.r cable & switch:, anchor, 1) ac points, ii) fan points (wall mount), iii) 15 amp points, iv) 05 amp points, v) main junction box with mcb, vi) led light points, led lights 2'x2' (syska/crompton/ panasonic) 36w, split acs 1.5 ton (lloyd), 3-star inverter, work table with fabricated of ms pipe with plywood with 3 drawers duly powder coated size:4' x 3', work table with fabricated of ms pipe with top plywood with 5mm rubber sheet 3 drawers powder coated, size:6' x 4', fabrication frame work with ms pole and perlin with black oil paint (10ft height with necessary structure) and r.c.c in foundation., shed over fabrication work of ceiling (0.5mm jindal), colour: white, bty operated crane 5 ton, i) lifting capacity - 5 ton, ii) lifting hight-500mm, iii) lower hight-500 mm, iv) safety features- self braking sys, v) usage indoor, portable & shop floor, vi) total boom length- 1200mm
Tender For service contract for anticorrosivecoating of cw pump of unit3 during unit3 oh25 periods under turbine maintenance at sgtpp wbpdcl through elt
Tender For supply, installation, testing and commissioning of extra material for installation of unitary acs in different departments /centers/schools, office etc. at iit kharagpur, kharagpur (phase i). - "supply, installation, testing and commissioning including vaccumization and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for split ac system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required :note: wall opening and making good to the damages.", "6.4 mm (¼"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "9.5 mm (⅜"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "12.7 mm (½"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "15.86 mm ( ⅝"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "19 mm (¾"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", interconnection electrical copper cables from indoor , outdoor & electrical control panel complete with 4 core 2.5 sqmm copper frls insulated cable(isi marked) with cable tie & clamp etc as required., supply & installation m.s epoxy painted fabricated stand for different size condensing unit with vibration isolators, grouting, for complete platform type stand for outdoor unit having safety railing etc as per site requirement., supply & installation of upvc drain pipe (isi marked) with 6mm thick nitrile rubber insulation from idu - 25mm dia, 40 mm rigid upvc drain pipe (isi marked) with 6 mm thick nitrile rubber insulation complete with fittings, u traps etc. & as specified to the nearest toilet with required civil works & finishing the same., supply of r-22 gas for top up, supply of r-32 gas for top up, supply & installation of good quality wooden frame (2" x 2") thick required for window ac installation, supply & installation of 16amps plug top (isi marked), supply & installation of 100mm pvc trunking with snap on trunking (isi marked), "supplying and installing following size of perforated hot dipped galvanised iron cable tray with cover (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.", 100 mm width x 50 mm depth x 1.6 mm thickness, 225 mm width x 50 mm depth x 1.6 mm thickness, 300 mm width x 50 mm depth x 1.6 mm thickness, installation, testing & commissioning of the window ,split acs ,cassette ac supplied by department. price shall be inclusive of installtion upto 3mtr of refrigerant pipe, drain pipe and cable., window acs, split acs, cassette acs, tower acs, reinstallation, lifting, shifting of existing ac units (split & window acs & cassette ac)., window acs, split acs, cassette acs, tower acs, dismantling of existing ac (split ac / window ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (cassette ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (tower ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, buy-back of existing unserviceable ac (split ac / window ac/cassette ac) units(all type) including all copper pipes, drain pipes mounting surfaces, etc. complete. the item shall be quoted as negat
Tender For repair/maintenance joint filling and epoxy/delpatch including repair to pqc slabs, pot holes at dispersals in airfield and grass cutting work and repair to runway shoulders and repair to pqc, surface cracks in airfield at tech area, af stn gwalior.