Tender For supply of lab equipment for department of instrumentation and control engineering - i/p and p/i converter, pressure measurement using bourdon tube and lvdt setup, level measurement using float and sight glass indicator, temperature transmitter trainer kit, single phase transformer with load, saybolt viscometer, on off control of temperature process, flow measurement using electromagnetic flowmeter
Tender For purchase of lab equipments for ice dept - purchase of lab equipments for ice dept, i/p and p/i converter (iemcode:g002) i/p converter:(4 20) ma to (3 15) psi conversion. p/i converter:(3 15) psi to (4 20) ma conversion. air filter regulator (afr):20 psi regulated air supply. built-in current source. 3 digit led display for process indication. power supply: 230 v ac, 50 hz. mounting:bench-top / panel-mounted trainer configuration., level measurement using float and sight glass indicator- itemcode: g005specifications: sight glass level indicator. float type level indicator. power supply:230 v ac, 50 hz. monoblock pump:0.5 hp / 1 hp. sump tank., 8051develop ment board with usb/rs 232 cable to connect with computer (item code: g008)specifications: communication interface:usb / rs-232. on-board facilities:8 output leds,8 input switches,ldr,reed switch,8-bit adc,8-bit dac. display interfaces:seven-segment display,16 2 lcd interface. motor interfacing:stepper motor with driver,dc motor with h-bridge driver, 8 bit adc/dac interface board (item code: g009)specifications: thermistor / lm35 input in one channel. variable input (0 5) v in another channel. 8 leds for digital output indication.. necessary control signals provided for adc0809. 8-bit dac using dac0808. 8-bit digital input from controller. single-channel dac output:(0 10) v. power supply: 12 v or 15 v for analog circuitry, water level measurement trainer kit using capacitive type transducer (item code: g020) tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20) ma and/or (0 5) v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement., flow measurement using electromagn etic flow meter(item code: g021)specifications: medium: water (salt water / bore well water). electromagnetic flow measurement: instantaneous flow rate and totalized flow indication. electromagnetic flow meter: integral mounted type. power supply: 90 260 v ac, 50 hz. minimum media conductivity: 15 s/cm. flow rate unit: m /hr. operating pressure: up to 10 kg/cm . electrode material: ss-304 / ss-316 / ss 316l. lining material: ptfe / neoprene / hard rubber / pfa. line size: 15 nb 25 nb. flow range: 0.1 10 m /hr. connection type: flanged. display: digital indication for flow rate and totalized flow. water pump: submersible type, 230 v ac, 50 hz. water tank: approximately 20 25 liters capacity. flow control valve provided. drain valve and overflow arrangement provided. mounted on powder-coated ms frame suitable for laboratory use.
Tender For for electrical and communication engineering department lab equipments are required as per new syllabus - upgradation of labarotariesece department, 8051 micro controller kit operating voltage: +5 v dc. flash memory: 4 kb (at89c51) / 8 kb (at89s52). ram: 128 bytes internal ram. 16 2 alphanumeric lcd display. push buttons / tactile switches. dip switches for digital input. inbuilt adc interface: ldr, potentiometer. inbuilt dac interface. inbuilt stepper motor driver with stepper motor. inbuilt dc motor driver with dc motor. 1 4 led array, 1 4 keypad, 1 relay. 1 buzzer, 16 2 lcd display, 1 pwm driver. 1 hardware interrupt key, inbuilt rtc. inbuilt eeprom and uart module. 4 7-segment display. supports both assembly and c language programming. pc interfaceable., single phase induction motor1 hp, 230 v ac, 1500 rpm with loading arrangement 1 no.voltmeter: (0 300) v ac, 96 96 mm with input terminals 1 no.ammeter: (0 10) a ac, 96 96 mm with input terminals 1 no.wattmeter: 2 kw, 96 96 mm with input terminals 1 no.power factor meter: 96 96 mm with input terminals 1 no.auto transformer: 0 300 v, 1 variac 1 no.mcb: 2-pole, 40 a / 230 v ac 1 no.digital rpm indicator with proximity sensor 1 no.aluminium brake drum: 230 mm diameter 1 no.spring balance: (0 25) kg 02 nos.circuit diagram printed on front panel with instruments and connecting terminals.motor and loading arrangement mounted on rigidchannel frame with anti-vibration mounting pads, m12 1.5 bolt & nut, 85 mm dia 4 nos.mild steel powder-coated electrical panel tablesetup., auto transformerinput: 230 240 v ac, 50 hz.output: variable (0 270) v ac.rating: 1 kva.insulation class: class f / class h.construction: copper winding with carbon brush arrangement.mounting: bench-top / panel type.protection: suitable fuse / overload protection., dth trainer kitpower supply: 200 v to 240 v ac, 50 hz. dish antenna: 1.5 ft aluminium steerable dish antenna.lnb (low noise block down converter): input frequency: ku-band. output frequency: 950 mhz to 1450 mhz. conversion gain: 65 db. noise temperature: 35 k (max).set-top box receiver in trainer form: if frequency: 70 mhz. video bandwidth: 50 hz to 5 mhz. video output level: 1 vpp at 75 load. video polarity: normal/inverted, switch selectable. audio subcarrier frequency:tunable from 5.0 mhz to 8.0 mhz. remote control provided. hdmi cable: 10 m. controls: channel selection. volume control. fault simulation: five built-in simulated faults for troubleshooting experiments. if signal disconnected. video output fault. audio mute fault. tuner misalignment. rf output interruption. pcb size: 15" 12" with multicolour section-wise block diagram.standard accessories: 1.5 ft dish antenna. lnb. trainer pcb. dish connecting wire. audio-video cable. user manual. acrylic cover. hardware materials for assembly of dish antenna. additional features: dth subscription connection with doordarshanfree channels., sim reader trainer kitpower supply: operates on 230 v ac 10%, 50 hz mains supply. built-in regulated smps power supply. operating dc supply: 5 v / 12 v with overload and short-circuit protection.sim card interface: supports gsm sim cards compatible with 2g / 3g / 4g / 5g networks. sim card read/write interface. supports sim card initialization, authentication, and communication functions. compatible with standard 6-pin / 8-pin sim card sockets.communication interface: usb 2.0 interface for pc communication. rs-232 serial communication interface. uart communication facility for embedded system interfacing.sim operating parameters: selectable sim clock frequencies: 3.579 mhz 7.159 mhz 14.318 mhz sim supply voltage selection facility. sim reset and activation control. supported protocols and standards: gsm etsi 07.07 and etsi 07.05 at command support. iso/iec 7816 smart card communication support. sim communication command monitoring facility. hardware features: on-board sim card socket. led indication for: power status sim detection reset activity data transmission/r
Tender For purchase of electronics and communication engineering practices (equipment) - equipments for electronics and communication engineering practices:, 8051 micro controller kit operating voltage: +5 v dc. flash memory: 4 kb (at89c51) / 8 kb (at89s52). ram: 128 bytes internal ram. 16 2 alphanumeric lcd display. push buttons / tactile switches. dip switches for digital input. inbuilt adc interface: ldr, potentiometer. inbuilt dac interface. inbuilt stepper motor driver with stepper motor. inbuilt dc motor driver with dc motor. 1 4 led array, 1 4 keypad, 1 relay. 1 buzzer, 16 2 lcd display, 1 pwm driver. 1 hardware interrupt key, inbuilt rtc. inbuilt eeprom and uart module. 4 7-segment display. supports both assembly and c language programming. pc interfaceable., embedded trainer kit (using lpc2148) cpu -lpc2148, core -16/32 bit arm7tdmi-s speed -max 60 mhz, flash -512kb, ram (on-chip) 40kb, 46 general purpose i/opins, usb2.0 one 10bit a/d converterwith 14 analog inputs, one 10bit d/a converter, six pwm &watchdog two uarts (16c550), two i2c (400kb/s), two spi eight bit digital output, eight bit digital input,16x2 characters lcd and 4x4 matrixkeypad one potentiometer for giving analog input, relay & buzzer interface i2c devices: rtc, eeprom and seven segment display, on board stepper motordriver lm35 temperature sensor, one rs 232 lines are terminated at 9 pin d type connector and usb interface board has inbuilt power supply and mounted in sturdy cabinet accessories usb cable with utility software to download programs from pc to target board power cord, user manual, ask modulation and demodulation kit message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz, amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. modulator type: switching modulator using analog switch / transistor switching ic. demodulator: envelope detector and lpf. comparator: lm311 based. supply voltage (board): +12 v, +5 v dc. supply current: 100 ma minimum. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., dth trainer kitpower supply: 200 v to 240 v ac, 50 hz.dish antenna: 1.5 ft aluminium steerable dish antenna.lnb (low noise block down converter):input frequency: ku-band. output frequency: 950 mhz to 1450 mhz. conversion gain: 65 db. noise temperature: 35 k (max).set-top box receiver in trainer form: if frequency: 70 mhz. video bandwidth: 50 hz to 5 mhz. video output level: 1 vpp at 75 load. video polarity: normal/inverted, switch selectable. audio subcarrier frequency: tunable from 5.0 mhz to 8.0 mhz. remote control provided. hdmi cable: 10 m.controls: channel selection. volume control.fault simulation: five built-in simulated faults for troubleshooting experiments. if signal disconnected. video output fault. audio mute fault. tuner misalignment. rf output interruption.pcb size: 15" 12" with multicolour section-wise block diagram.standard accessories: 1.5 ft dish antenna. lnb. trainer pcb. dish connecting wire. audio-video cable. user manual. acrylic cover. hardware materials for assembly of dish antenna.additional features: dth subscription connection with doordarshanfree channels. free-to-air channel demonstration.
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For purchase of instrumentation and control engineering practices (equipment) - motorized control valve trainer kit signal input:4 20 ma or 0 5 v valve characteristic:equal percentage stem movement:maximum 10 mm or 12 mm body material:cast iron trim material:ss 316 trim size: cv value:2 or 5 actuator:servo motor supply voltage:230 v ac, 50 hz connection: flanged or screwed type. digital indicator provided potentiometer provided for varying the 4 20 ma input signal, saybolt viscometer apparatus glass type: high-quality borosilicate glass tube. control type: manual energy regulator control. shape: rectangular bath with cylindrical test chamber. temperature range: ambient to 240 c oil bath temperature. humidity: up to 80% rh (non-condensing). power supply: 230 v ac, 50 hz. measuring range: 32 to 1000 sus(saybolt universal seconds). accuracy: as per astm d-88( 0.2 seconds). mounting type:benchtop. capacity:one cup(approximately 60 ml). control mode:manual operation. port size:standard orifice sizeas per astm d-88. features:oil bath with heater,thermoregulator,insulated outer body,orifice,receiver flask, control valve trainer kit three pneumatic control valves provided with individual hand valves valve characteristics: i) quick opening ii) linear iii) equal percentage. valves connected in parallel configuration for comparative study. pneumatic operation with air supply connection. control valve assembly mounted on trainer panel. power supply: 230 v ac, 50 hz., water level measurement trainer kit using capacitive type transducer tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20)ma and/or (0 5)v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement.
Tender For supply of solar insulation meter , pyranometer , pyrheliometer , lux meter lux meter lcd read out 005 to 7000 lumens with battery , magnetic flux meter 0500 tesla , tong tester clamp meter 0 100 a digital type , soldering iron set 25 watt 65 watt and 120 watt 230 volt set of 3 , temperature controlled soldering iron 50 watt 230 volt , thermometer digital 0 degree c 150 degree c , sun shine recorder , weather monitoring station to monitor and record unshine wind velocity temperature rainfall etc with software , solar cell based sunlight radiation meter for solar power measurement up to 2000 wsquare meter , magnetic compass , cut models of photo voltaic cell assembly , model of lead acid battery , lead acid battery set 12v 40ah 75ah , lead acid battery 12v 100 ah , solar simulator for solar cell characteristic study to study iv curve of a solar cell of minimum 2 watt under variable illumination temperature and suitable load , iv curve tester , sun path finder , solar energy trainer with grouping of solar cells to group series or parallel at least six solar cells each with minimum 2 w with suitable loads , solar tracker demonstrator kit to study manual and automatic control of 10 w solar panel in east west and northsouth andback , halogen lamp set with stand for illumination of solar panels in lab ac mains operated to provide 0 to 1000 watts per meter square , pedestal grinder double ended 300 mm , battery charger 0 6 9 12 24 48 v 30amp , solar photovoltaic module 10 w poly crystalline module , solar photovoltaic module 250 w , solar photovoltaic module 250 w thin film module , solar photovoltaic module 40 w poly crystalline module , solar photovoltaic module 5 w poly crystalline module , solar photovoltaic module 75 w amorphous silicon module , solar photovoltaic module 75 w mono crystalline module , solar panels 250 wp , solar charge controller with dusk to dawn automatic switching 12v 10a , solar charge controller with manual switch day lighting 12 v 10 a , array junction box for connecting 250w x 4 nos solar panel with dc fuse dc mcb and surge suppressor protection , solar lantern led type , solar lantern cfl type , solar lantern assembly sets , home light system 12 v dc with fm receiver led bulb and mobile charger as loads , solar cell kit , clinometer for angle measurement , spirit level for floor level check , anemometer for wind speed measurement , dc table fan 12 v , ac voltmeter mi 0 , providing and supplying of volt meter 0 30v , volt meter 0 100v , ammeter mc 0 1a , ammeter mc 0 5a , ammeter mc centre zero 0 20a , ammeter mc centre zero 050a , power factor meter , rheostat set 0 1 ohm 5 amp 0 10 ohm 5 amp 0 25 ohm 1 amp 0 300 ohm 1 amp set , ac energy meter single phase 10 a 240 v inductiontype , ac energy meter three phase 15 a 440 v induction type , kilo wattmeter analog , digital wattmeter 230 v 1 kw 50 hz , phase sequence indicator 3 phase 415 v , frequency meter 45 to 55 hz , dc led lamp set 3w 5w 10w set of 3 , dc pump 24 v , pwm controller , mppt charge controller , solar grid tied inverter demonstrator kit 300w kw