Web Analytics Made Easy - StatCounter

Antifreeze Tenders

Get complete information related to latest Antifreeze Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Antifreeze Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Antifreeze Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45737212 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of portable digital refractometer for testing antifreeze coolant with display of range 0-100% of resolution 0.1% and accuracy +/- 0.2% as per the specification attached. note: nabl/oem calibrationcertificate should be provided with the equipment. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45713858 Due date: 18 Jul, 202618 Jul, 2026 25.00 Lacs
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45560058 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For corrigendum : tender for supply of clamp meter , 5 gallon compressor oil tin , core for filter drier , filter drier core rpe48bd , relay base type rxze2m114 , relay 24v dc 4 co rxm4ab2bd , single core 40 mmsqlfh cable , ss washer 125 , screw driver set , ss 304 tubing , pilot tube fitting , filter drier replacement core , potentiometer shaft , relay , store room thermostat , piston set , valve plate set , pocket for temp switch , gasket , therm injection valve , defrost heater element tat 30 , shut off valve , shut off valve , shut off valve , temperature transmitter pt 10 , solenoid valve on oil return line , condensers of chilled water units ac , thermometer discharge line , thermometer cwinlet , flex metal hose , oil heater , therm injection valve , needle valve , gauge oil pressure , feeler pocked , stop valve , stop valve , power contactor 115 vac , air contactor , chilled water pump of air conditioning plant , fuse 500v , relay 24vdc , rc module , auto controller , antifreeze thermostat , fuse switch , fuse switch , sight glass set , current meter , pilot lamp , valve relief , metaflex coupling api 671

CTN :45215052 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : supply of antifreeze coolant (v2) conforming to is 5759 (q3)

CTN :45351105 Due date: 30 Jun, 202630 Jun, 2026 38.00 Lacs
Tender For bid to ras bid to ras supply of medical equipment to community health centre : : - fully automated biochemistry analyzer , hematology cell counter , hb a one c automatic analyzer , centrifuge , electrolyte analyzer , urine analyzer , immunoassay analyzer , multipara cardiac monitor , control reagent , lef ast alp reagent , bilirubin reagent , protein and albumin reagent , diluent reagent , lyser reagent for hematology analyser , hbaic reagent , cleanser reagent , urea reagent , creatinine reagent , glucose reagent , calcium reagent , cardiac makers reagent , strip box , blood collection tubes , combination therapy unit , cupping therapy set , needles oblique syringe destroyer , bp machine and stethoscope , automated external defibrillator , electric sterilizer machine , refrigerator , consumables item , ecg machine , lab assistance tranging , desktop pc and printer , lab furniture

CTN :45437191 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For bid to ras supply of multipurpose industrial grease (v2) conforming to is 7623 (q3) , antiwear hydraulic oil, extra heavy duty type (v3) conforming to is 11656 (q2) , gear lubricants, multipurpose (?extreme?pressure?gear?oil?) (v3) conforming to is 1118 (q3) , antifreeze coolant (v2) conforming to is 5759 (q3) , servo pride xl 15w40 , servo ultra kb 30 , servo ultra kb 10 , servo gear super 80w90 , grease wb , servo transmission f10 , servo transmission t20 , servo system hlp 32 , servo system hlp 46 , servo system 100 , servo hydrex th 46 , servo hydred 100 , r 100 , 5w40 , 5w30 , alt 90 , sac capsules , hp super trans , stf a , jcb transmission utto oil , hvi hyd fluid , jcb gear oil , jcb hvi hyd fluid , eng oil 15w40 for bs vi , dte 10 excel 32 mobile hydraulic oil , tutela ldf 05w30 eng oil , tutela atf dextron iii tutela car g1 hyd oil , scania ready mix 50 by 50 coolant radicool , tutela wo m-da sae 80w90 gear oil , eng oil sea 10w30 , eng oil gulf leypower xle , radiator coolant leycool 40 , winch gear box fear oil vg 150 , front axle hypoi gear oil mil 121058 api gl5 , transmission tq gear oil sae 40 , slew and cable lubricant grease epl 2 , def tata , def eicher , def gulf , def add blue al aus32 , def add blue rosblue for sml , hyther m 500 * /bid number : gem/2026/b/7619792 + /dated: 04-06-2026 ' ' / bid document 1 / 39

CTN :45543792 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For bid to ras polaris premium 50/50 antifreeze coolant

State Government

CTN :45673223 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of c oil , steering oil tq oil , m oil 20w40 , greese , m oil 15w40 , m oil gtx 20w50 , brake oil , diesel exhaust fluid ad blu , coolant antifreeze , super 2t , c oil 140 degree , distrilled water , c oil 80 degree , brake oil dot 4 , red greese , oil funnel , steering oil for bolero , ad blu for bolero , bucket oil pump with wheel 16 litres
 Loading, Please wait...

Connect us via What's Up