Tender For supply of 3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz, rated current 1.2 amps. capacitor should have discharge resistor- e and over pressure disconnection.as per rdso modification.sheet no.rdso/pe/ms/ac/0054-2011 rev.0 or latest and confirming to is:13340 with isi mark. suitable for capacitor bank of lhb ac coach. make: m/s epcos or m/s vishay or any other equivalent capacitor confirming to is: 13340 with isi mark and having property as defined in table-1 according to rdso/pe/ms/ac/0054-2011 rev.0 (firm shall submit complete type test report as per is 13340 along with latest isi certification)
Tender For corrigendum : rca for procurement of local purchase materials required for operations and maintenance of equipmets of 33/11 kv s/ under city cirle bhopal. - various tripping coil, various closing coil, expulsion fuse 20 a. for capacitor bank ( for 100 kvar unit ), expulsion fuse 40a for capacitor bank ( for 200 kvar unit ), silica gel, breather for ptr (capacity- 3 kg.), robust high ampacity smart connector for ct/pt/me, m-16, robust high ampacity smart connector for ct/pt/me, m-20, c&r panel indicators, tnc switch, mfm, buchholz relay, mog, 11 kv vacuum interrupter make- cg (suitable for cg/megawin/bhel), 11 kv vacuum interrupter make- stelmec (suitable for stelmec), robust high ampacity smart connector for ptr of size m-20 for raccoon/dog, robust high ampacity smart connector for ptr of size m-20 for panther, gi nut bolts assorted size, rubber cork seat 4 mm, rubber cork seat 10 mm, oil temperature indicator (oti), winding temperature indicator (wti), smart t clamp of all sizes, smart pg clamp of all sizes, isolator pad clamp, 30 volt dc bell, ampere meter selector switch, voltmeter selector switch, dc mcb 16 amp, ac mcb 16 amp, mft (multi-functional transducer), cmr ( contact multiplying relay), auxiliary switch-8 no+8 nc ( suitable for the vcb s of different makes), spring charging motor (suitable for the vcb s of different makes), pull rod suitable for vcb s of different makes, fuse wires tinned copper 15 swg, fuse wires tinned copper 16 swg, fuse wires tinned copper 18 swg, fuse wires tinned copper 12 swg, fuse wires tinned copper 21 swg, fuse wires tinned copper 14 swg, aluminium lugs 70 sqmm, aluminium lugs 95 sqmm, aluminium lugs 150 sqmm, aluminium lugs 300 sqmm, do fuse elements 1 amp., do fuse elements 1.5 amp., do fuse elements 3.3 amp., do fuse elements 3 amp., do fuse elements 5 amp., do fuse elements 10 amp., do fuse elements 15 amp., male/female contacts for 11 kv ab switches 400 amp., male/female contacts for 33 kv ab switches 600 amp., aluminium ladder, smart connector suitable for ab switch terminal (50x50) to dog raccon conductor, smart connector suitable for isolator/ cb (75x75 mm) terminal to dog/ raccorn conductor, kit kat fuse unit 300 amp., kit kat fuse unit 200 amp., robust lt pole fuse unit, hrc fuse base100 amp., hrc fuse base 200 amp., hrc fuse base 250 amp., hrc fuse base 400 amp., torch cell 1.5 volt, pvc insulation tape, rubber hand gloves 11 kv, rubber hand gloves 33 kv, sefty helmet, discharge rod, gum boot, sefty bellt jhula, screw driver 12, screw driver 6, screw driver 8, pencil type neon tester, insulated combination cutting piler 8, lineman tool bag, rubber conical washer rubber conical washer suitable for 12 mm stud(hv side), rubber conical washer suitable for 12 mm stud (lv side), bamboo ladder, street lights (including dual fixtures) power rating: 200 watt, tong tester, multi meter, insulation megger tester, earth resistance tester, ac volt meter, ac amp. meter, dc volt meter, dc amp. meter
Tender For repair / replacement and maintenance of lt switch gears, panel, apfcpanels, capacitor bank and connected item at certain location of 54 arty bde, arty regt, armd regt area and certain otm accomodation at zone 1c under age em i of ge (u) secunderabad
Tender For corrigendum : supply, installation, testing and commissioning of 5 nos. of five step auto switch capacitor bank of rating 3.76 mvar (12.65 kv design voltage) 2.85 mvar (11 kv system voltage) in ndmc area
Tender For corrigendum : adding 02 nos. 33kv sirsabiba mau and saraibhupat feeder bay including dismentling and erection also of 02 nos. 2x10mvar, 33 kv capacitor bank and extension of 33 kv main and transfer bus at 132 kv substation jaswantnagar under etd, etawah .
Tender For supply of electrical maintenance testing and line patrolling services d d--sply of electrician gs and 3s , sply of electrician in exigency , hiring electrical supervisor , earth pit testing , testing of relay , servicing of acb , servicing of vcb , testing and checking vcb bottle , transformer oil filtration , transformer oil testing , thermography of equipment , servicing of capacitor bank , cea inspection , sfra testing of transformer , testing of third harmonic la , testing insulation resistance half yearl , testing and calib otianalog digi , testing and calib wtianalog digi , testing of insulation mats , sup of transformer oil , dg wr and ir testing , pd test transformer , ir and pi test for transformer , tan delta test for transformer , line patrolling trips
Tender For supply of preparation of drawings, documents, manufacture, assembly, inspection, testing of winding assembly o , design, testing, supply of 100 kvar capacitor bank, shipment, guarantee and safe delivery to kalpakk