Web Analytics Made Easy - StatCounter

Apfc Panel Repair Tenders

Get complete information related to latest Apfc Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Apfc Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Apfc Panel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43866843 Due date: 14 Apr, 202614 Apr, 2026 19.90 Crore
Tender For bid to ras corrigendum : tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables

corporations/Associations/Others

CTN :44781846 Due date: 21 Apr, 202621 Apr, 2026 14.29 Lacs
Tender For procurement of electrical spares for automatic power factor control apfc panel

CTN :43725347 Due date: 11 Apr, 202611 Apr, 2026 NA
Tender For bid to ras supply of supply and validation of ruggedized electrical assemblies for mbt arjun mk ia - assy instrument panel rh as per appendix a , assy integrated drivers switch board as per appendix a , assy integrated fuel, bilge, charger box as per appendix a , assy inter vehicle starting socket as per appendix a , assy fuel level indicator box as per appendix a , assy instrument panel junction box as per appendix a , assy engine control junction box as per appendix a , assy master relay box as per appendix a , assy turret switch board as per appendix a , assy nbc control box as per appendix a , assy emi filter box as per appendix a , assy turret power control box as per appendix a , assy turret distribution junction box as per appendix a , validation testing charges as per appendix b

State Government

CTN :44798192 Due date: 28 Apr, 202628 Apr, 2026 1.97 Lacs
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge

Central Government/Public Sector

CTN :44687509 Due date: 14 Apr, 202614 Apr, 2026 NA
Tender For corrigendum : supply of supply, installation and commissioning of electrical control panel and other accessories

Central Government/Public Sector

CTN :44492010 Due date: 13 Apr, 202613 Apr, 2026 1.46 Lacs
Tender For corrigendum : for the work of repair and maintenance work (pre mansoon) of 21 no. radial gate of size (13.716x 15.450) mtr. 21 no. radial gate control panel (electrical) at rabls project bargi dam jabalpur.

CTN :44762724 Due date: 15 Apr, 202615 Apr, 2026 NA
Tender For quotation for the rate fixation of quotation for the rate fixation of supply, installation, testing, and commissioning of a complete waterfall system for 6.00mtr dia pond as per design, including gi rings for 3-step waterfall formation with ball joint nozzles placed at varying lengths, narrow pool waterfall ss nozzles and plates, and illumination using waterproof led rgb lights with appropriate drivers and cabling. the system shall be operated by a 10 hp submersible horizontal mono block pump set of reputed make, complete with pump strainer, header with water distribution manifold, pressure regulating valves, and all necessary fittings. an outdoor weatherproof electrical panel shall be provided, comprising a starter, ammeter, voltmeter, and other required control and safety components. the entire unit shall be fully operable with the inclusion of any missing accessories, excluding civil works,

CTN :44774440 Due date: 15 Apr, 202615 Apr, 2026 4.30 Lacs
Tender For providing electrical panel along with construction of control room 15 x 18 in ngm at mohna

CTN :43994967 Due date: 15 Apr, 202615 Apr, 2026 12.13 Crore
Tender For corrigendum : invites for e-bids. from original equipment manufacturers (oems) and/or authorised channel partners (cps) supply of goods, tools &equipmentforan international standard itotin electrician tradeat iti vyara, gujarat, india - electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines (single phase and three phases). should be fitted with friction brake arrangement, dynamometer, and instrument panel and power supply unit., motor-generator (ac to dc) consisting of: squirrel cage induction motor with star-delta starter and directly coupled to dc shunt generator and switch board mounted with regulator, air breaker, ammeter, voltmeter, knife blade switches and fuses, set complete with case iron and plate, fixing bolts, foundation bolts and flexible coupling. induction motor rating: dc shunt generator rating: induction motor rating: dc shunt generator rating:, motor generator (dc to ac) set consisting of-shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed plate, fixing bolts, foundation bolts and flexible coupling. shunt motor rating: ac generator rating:, linear i.c. trainer, digital i.c. trainer, component of typical small hydro power, component of typical water mill, low voltage control and systems. with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, residential and small business systems with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, building control systems and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, industrial control system and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, solar system lab suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, training system predictive maintenance and condition monitoring of electric drives, electric vehicle motors and battery training & test bench, industrial electrical testing facility with circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the testing by the student, ar-vr training set up., portable electric drill machine, pillar electric drill machine, outside micrometer, motorized bench grinder, rawl plug tool & bit, hydrometer, thermometer, soldering iron, copper bit soldering iron, de soldering gun, table vice, ohm meter; series type & shunt type, stock and dies conduit, multi meter (analog), digital multi meter, a.c. voltmeter, milli voltmeter, d.c. milliammeter, ammeter, a.c. ammeter, a.c. ammeter, kilo wattmeter, a.c. energy meter, power factor meter, frequency meter (analog + digital), tachometer with stopwatch, current transformer primary-, potential transformer, growler internal+ external, tong tester / clamp meter, megger, wheat stone bridge with galvanometer & battery 2 nos, earth tester, electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines (single phase and three phases). should be fitted with friction brake arrangement, dynamometer, and instrument panel and power supply unit., motor-generator (ac to dc) consisting of: squirrel cage induction motor with star-delta starter and directly coupled to dc shunt generator and switch board mounted with regulator, air breaker, ammeter, voltmeter, knife blade switches and fuses, set complete with case iron and pl

Central Government/Public Sector

CTN :44736841 Due date: 17 Apr, 202617 Apr, 2026 NA
Tender For request of budgetary quote for supply, installation, testing and commissioning of safety circle inside port premises near immigration center 1). signage led screen with metal fabrication support metal fabrication for screen & logo providing and installing branding led circular shape screen, including supply of led display. panel. ms fabrication frame structure with proper support, anchoring and alignment, internal wiring, power supply arrangement, weather protection, testing and commissioning. complete in all respects as per approved design and site requirements. 2). turbine tree 3). fountain providing, supplying, installing. testing and commissioning of 10 nos. 1" foam nozzles with accessories and 16 nos. 12v, 18w underwater rgb led lights. supply and installation of 2 nos. kirloskar brothers limited make 5hp, 440v open well pumps with related fittings. providing and commissioning of 2 nos. electrical control panels with dol starter, elcb and overload protection system. complete upvc astm plumbing inside pond and 150 meters of 0.5 sq.mm x 4 core isi flexible cable for pump and lighting work. 4). mosaic tiles in fountain/pond area 5). providing and fixing mosaic tiles in fountain/pond area, including cleaning and surface preparation, application of waterproof adhesive, proper laying with alignment, epoxy grouting of joints, edge finishing and curing, complete in all respects as per site requirements water proofing providing and applying waterproofing treatment to fountain/pond area, including surface preparation, crack filling, application of approved waterproofing chemical/compound in required coats, curing, and testing for leakage, complete in all respects as per site requirements. 6). light pole providing and erecting metal street light pole of approved height and design, base plate, anchor bolts, internal wiring provision, painting/coating for corrosion protection, and complete installation in all respects as per site requirements. 7). acrylic signage providing and fixing acrylic signage, including laser-cut acrylic letters, uv printing as required, ms frame for support, led backlit provision. proper alignment and mounting, complete in all respects as per approved design and site requirements. 8). rcc work providing and laying rcc slab of m25 grade having thickness 250 mm to 300mm 9). bermuda carpet effect grass with plants providing and executing landscape work including preparation and dressing of soil, supply and plantation of approved shrubs, ornamental plants and trees with manure and watering system, laying of natural/lawn grass with proper leveling and rolling, and decorative pebble work around plants and pathways for aesthetic finish, complete in all respects as per approved layout and site requirements. 10). granite top & wall cladding with required wall & plaster work providing and fixing granite top and wall cladding work, including required surface preparation, necessary wall construction plastering, adhesive fixing, proper alignment, joint filling, edge polishing and finishing. complete in all respects as per approved design and site requirements. 11). electrical lights & points providing, supplying. installing. testing and commissioning of electrical main line including supply and laying of required cables, conduits, distribution connections, and complete wiring for all lights, along with supply of fixtures, fittings, accessories, labour charges and testing, complete in all respects as per site requirements. 12). main line of water supply & return providing, supplying. installing. testing and commissioning of main water supply and return line system, including excavation, supply and laying of approved quality pipes, fittings, valves, joints, supports, connection to pumps/tanks, pressure testing and commissioning, complete in all respects as per site requirements. 13). ss metal logo on top providing and installing 12 feet height ss-(stainless steel) metal revolving logo structure, including
 Loading, Please wait...

Connect us via What's Up