Get complete information related to latest Apfc Panels Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Apfc Panels Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Apfc Panels Tenders.
Tender For corrigendum : repair/maint of lt ug cables, switch gears, bus bars, lt panels distribution systems, apfcpanels etc and connected works in tech area af stn gwalior
Tender For repair and periodic maintenance of dg sets, amf panels, solar water heater, swimming pool, lt ug cables, poles, apfcpanels, busbar panels and other allied external electrification works at af stn chandinagar under aor of ge (af) faridabad
Tender For ge/h/t-25 /2026-27 repair/ maintenance of lt distribution system, acbs, apfcpanels and other connected works at ahrr under ge e/m rr hosp delhi cantt-10
Tender For ame for temporary illuminations, amf panels, apfcpanels, ups system etc. in sv temple at kanyakumari in tamilnadu state pertaining to ae-i section in esd-iii, tirupati for the year 2026-27
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
Tender For supply of electrical materials for day to day maintenance of electrical assets at various permanent mixed/storm pumping stations under eee-i shahdara (north) zone - supply of 9 watt led retrofit lamp suitable for b22 holder, supply of cceiling fan with brush less direct current (bldc) motor, etc. complete as req , 1200mm, bee 5 star rating, service value 6.0 cm/min/watt, air delivery 210 cm/min (minimum), supply of led batten light (system lumen efficacy 120 135 lm/watt) of following body materials. powder coated die cast /extruded aluminium body (thickness > 1.20 mm) 18-22 watt, supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required., supply of 15 inch (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as required., suppy of 1.5 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable, supply of 4.0 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable, supply of 2.5 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable., supply of 10 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable., supply of 6.0 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable., supply of 16 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable, supply of 125 a, tpn, switch disconnector fuse unit (panel mounted type) with isi marked hrc fuses, supply of 200a tpn switch fuse unit with isi marked hrc fuses, supply of 4 pole mccb, 125a, 36ka ics=100% icu and operational voltage 690v, supply of 4 pole mccb,250a, 50ka ics=100% icu and operational voltage 690v, supply of 4 pole mccb,400a, 50ka ics=100% icu and operational voltage 690v, supply of 4 pole mccb,630a, 50ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 200a, 16ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 125a, 16ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 250a, 35ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 400a, 35ka ics=100% icu and operational voltage 690v, supply of brass batten/angle holder, supply of 6 pin 15/16 & 5/6 a socket outlet, piano type isi marked, supply of s.p. 15/16 a, one way switch, piano type isi marked, supply of 3 pin 5/6 a socket outlet, piano type isi marked, supply of s.p. 5/6 a, one way switch, piano type isi marked, supply of stepped type modular fan regulator (2 module), supply of 3 mm thich phenolic laminated sheet, supply of 63 amp, 4 pole isolator., supply of 63 amp, 2 pole isolator., supply of 40 amp, 2 pole isolator., supply of 6 to 32 a, ratings sp mcb, c curve, 10 ka braking capacity, supply of 6 to 32 a, ratings dp mcb, c curve, 10 ka braking capacity, supply of 6 pin 15/16 a modular socket outlet, isi marked, supply of 3 pin 5/6 a, modular socket outlet, isi marked, supply of s.p. 15/16 a, one way modular switch, isi marked, supply of s.p. 5/6 a, one way modular switch, isi marked, supply of led flood light, powder coated pressure die cast aluminium (system lumen efficacy >135 lm/watt) of following body materials. 150 watt
Tender For tender for the work supply, installation, testing and commissioning (supply, installation, testing, and commissioning) of diesel generator (dg) set, soft starter panels, and apfcpanels at the intake well and water treatment plant (wtp) on a turnkey basis with individual item-rate sanctions i