Get complete information related to latest Apfc Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Apfc Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Apfc Relay Tenders.
Tender For repairs and restoration work of automatic power factor corrector (apfc) panel and main lt panel including plc software development and apfcrelay programming at substation ofbolpur super speciality hospital
Tender For corrigendum : repairs and restoration work of automatic power factor corrector (apfc) panel and main lt panel including plc software development and apfcrelay programming at substation of bolpur super speciality hospital, district-birbhum. - “repairs and restoration work of automatic power factor corrector (apfc) panel and main lt panel including plc software development and apfcrelay programming at substation of bolpur super speciality hospital, district: birbhum. ”
Tender For supply, fixing, testing and commissioning of 100 kvar apfc panel, with crca sheet of thickness 2.00 mm with 7 tank process powder coated, ip-54 consisting of the followings:- (1) main mccb 250 amp 3 pole 35/36ka - 01 no., (2) main copper bus bar tpn 400a capacity -01 set, (3) apfcrelay 8 stage - 01 no. (4) led indicator r/y/b -03 nos, (5) mccb 100 a 3-pole 10 ka -02 nos. (6) mcb 40 a 3-pole 10 ka -02 nos.(7) mcb 32 a 3 pole 10 ka-01 no. , (8) mcb 20 a 3-pole 10 ka - 01 no., (9) mcb 10 a 3 pole 10 ka - 01 no. (10) mcb 6 a 3-pole 10 ka - 01 no. (11) contactor capacity duty type:- moc 25 for 25 kvar - 02 no. (12) moc 15 for 15 kvar- 02 no(13) moc 10 for 10 kvar -01 no. (14) moc 05 for 05 kvar -01 no.(15) moc 03 for 03 kvar -01 no.(16) moc 02 for 02 kvar- 01 no .(17) heavy duty capacitor :- 25 kvar - 02 no, 15 kvar- 02 no., 10kvar-01 no. 05 kvar - 01 no., 3kvar- 01 no., 2kvar - 01 no. (18) auto manual selector switch -08 nos. (19) led indicator on off- 16 nos. (20) control and power cable frls copper , ( 21) ct-as per requirement, including all accessories for commissioning complete in all respect as per direction of sse in-charge, test report from govt. lab/nabl /ilac lab to be submitted at the time of supply. specification as per iec 61921/ is 8623/ is 16636/ iec 61439. make abb/ havells/ l&t/siemens or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, fixing, testing and commissioning of 200 kvar apfc panel, with cubical modular construction floor mounting dust and vermin proof made of 14/16 swg crca sheet as per latest approved specification is standard and harmonic block reactor with capacitors 25 kvar, 04 banks, capacitors 20 kvar , 02 banks, capacitors 15 kvar , 02 banks, capacitors 10 kvar , 02 banks capacitor 5 kvar , 01 banks, capacitors , 03 kvar , 01 banks, capacitor 02 kvar , 01 banks, comprising of housing, capacitors banks apfcrelays, mccb/mcb protection, with all accessories including mounting arrangements suitable to work on 3 phase 440 volts,50 hz ac supply. features: automatically switch on and switch off relevant capacitor steps to ensure consistent power factor, continuously sense and monitor the load conditions by the use of the external ct ( whose out put is fed to the control relay), double side earthing connection, advance c-mos technology based microprocessor relay for intelligent power factor control, provision of top & bottom cable entry ,ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out, test report from govt. lab/nabl /ilac lab to be submitted at the time of supply, specification as per iec 61921/ is 8623/ is 16636/ iec 61439.makeabb/ havells/ l&t/siemens or similar. [ warranty period: 12 months after the date of delivery ] ]
Tender For supply of apfc capacitor bank panel - supply, instalation and commissioning of apfc capacitor bank panel with apfcrelay with automating load control panel of 1250 kvr trail testing of apfc panel and outgoing supply of feeder will be connection and load trial. as per bellow detail specification make- l & t details of fabrication of panel cubical- free standing floor mounted with ismc chanel base 100x50x5mm front oprated indoor type ip44, powder coated, color-siemens gray ral-7035)hardwae, gasket,door lock, wiring, ferul etc sheet 2.2/1.6mmmm crca. note - 1-1- panel will be ms fabricated and powder coated as per industry standard, 2-all wires will be used fire proof standard. 3-the paneles muist be of iec/nec standards.4- all type of modification of old bus duct as per requiredment of sit.5- panel coolling axial fan 8inch/panel illumination lamps/thermo stat-30-90 degree.6-apfcrelay microprossessor based-16 stage.7-acb used mdo 1.5g microprossessor based release uv., supply, instalation and commissioning with all bolts ,angle and supporting tool & takel with hardware as per requirerment of new aluminium bus bar grade- e91e with ducting, cap. 2,500 amp + 0.8 pf. all necessary conection will be done. make: hendalco
Tender For supply of various electrical lt switch gears control equipment and cables in the ltdb of power load b b - supply of 630 amp 3 pole mccb 415 volt, , supply of spreader link for 630-amp 3 po , supply of extended rod with handle 630-a , supply of ring ct make- kappa, ratio- 60 , supply of 400 amp 3 pole mccb 415 volt, , supply of spreader link for 400-amp 3 po , supply of extended rod with handle 400-a , supply of ring ct make- kappa, ratio- 40 , supply of 200 amp 3 pole mccb 415 volt, , supply of spreader link for 200-amp 3 po , supply of extended rod with handle 200-a , supply of ring ct make- kappa, ratio- 20 , supply of 100 amp 3 pole mccb 415 volt, , supply of spreader terminal for 100-amp , supply of extended rod with handle 100-a , supply of ring ct make- kappa, ratio- 10 , replacement and retrofitting of 630 amp 3 , replacement and retrofitting of 400 amp 3 , replacement and retrofitting of 200 amp 3 , replacement and retrofitting of 100 amp 3 , supply of 95 sq mm single core copper fl , laying of 95 sq mm single core copper ca , supply, replacement and re-fixing of 95 , supply of indicating led lamp red- 60 n , replacement and re-fixing of indicating , supply of multifunction meter make- secu , installation, calibration, testing and ret , supply of auxiliary contactor for mccb m , ring ct installation and retrofitting , control cable connection and circuit mod , supply of 2.5 sq mm flexible wire , supply of 400 amp 3 pole power contactor , supply of 160 amp 3 pole power contactor , supply of 160 amp 3 pole mccb for capaci , supply of spreader terminal for 160-amp , supply of extended rod with handle 160-a , replacement and retro-fitting of 400 am , replacement and retro-fitting charges fo , replacement and retro-fitting of 160 amp , supply of 12 window apfcrelay, make- ep , replacement and retro-fitting charges fo , supply of 3-phase digital voltmeter make , supply of 3-phase digital ammeter make- , replacement and retro-fitting of 3-phase , rectification and restoration of mechanic , supply of 300 sq mm, 3.5 core, 1.1 kv gr , supply, fitting and fixing of gland for 30 , laying of 3.5 core, 1.1 kv grade armoure , supply and replacement of socket for 300 s , manual disconnecting of power supply, di , supply, installation, testing and commis
Tender For corrigendum : supply of newfront hmi of p141 micom relay as per bid requirement mentioned in atc. , newfront hmi of p442 micom relay as per bid requirement mentioned in atc. , 3.6v, 1200mah half aa lithium battery as per bid requirement mentioned in atc. , hand reset and electrical reset, flag indicating 220v dc electromagnetic tripping and control relay as per bid requirement mentioned in atc. , self reset, flag indicating single element 220v dc operated electromagnetic tripping and control relay as per bid requirement mentioned in atc. , electrical reset, flag indicating single element 220v dc operated electromagnetic voltage selection relay as per bid requirement mentioned in atc. , self reset, flag indicating 220v dc operated electromagnetic trip circuit supervision relay as per bid requirement mentioned in atc. , self reset, reverse flag indicating single element 220v dc operated electromagnetic dc circuit supervision relay as per bid requirement mentioned in atc. , self reset, flag indicating single element 220v dc operated electromagnetic change over relay as per bid requirement mentioned in atc. , self reset, flag indicating 220v dc operated electromagnetic change over relay as per bid requirement mentioned in atc. , self reset, three element 220v dc operated electromagnetic change over relay as per bid requirement mentioned in atc. , hand reset, flag indicating 220v dc electromagnetic high speed tripping and control relay as per bid requirement mentioned in atc. , hand reset, flag indicating 220v dc operated electromagnetic auxiliary relay as per bid requirement mentioned in atc. , hand reset, flag indicating three element 220v dc operated electromagnetic auxiliary relay as per bid requirement mentioned in atc. , hand reset, flag indicating 220v dc electromagnetic master tripping and control relay as per bid requirement mentioned in atc. , self reset 220v dc operated electromagnetic trip circuit supervision relay as per bid requirement mentioned in atc. , hand reset, led indicating 220v dc operated electromagnetic auxiliary relay as per bid requirement mentioned in atc. supply, testing, packing, transit insurance, safe delivery and warranty of newfront hmi of p141 micom relay with model no.: p141316a6m0410j and make: m/s schneider electric., supply, testing, packing, transit insurance, safe delivery and warranty of newfront hmi of p442 micom relay with model no.: p442316b6m0400k and make: m/s schneider electric, supply, testing, packing, transit insurance, safe delivery and warranty of 3.6v, 1200mah aa lithium battery suitable for px4x micom relay front hmi application. preferable make m/s tadiran, supply, testing, packing, transit insurance, safe delivery and warranty of hand reset & electrical reset, flag indicating 220v dc electromagnetic tripping & control relay with 20 nos (16no+4nc) of contacts, case size-4 and flush mounting ge make, type:mvaj205-l and model: mvaj205la1004a in 86 a/b group trip application., supply, testing, packing, transit insurance, safe delivery and warranty of hand reset & electrical reset, flag indicating 220v dc electromagnetic tripping & control relay with 10 nos (8no+2nc) of contacts, case size-2 and flush mounting ge make, type:mvaj105-l and model: mvaj105ja1002a in 96 busbar protection trip application., supply, testing, packing, transit insurance, safe delivery and warranty of self reset, flag indicating single element 220v dc operated electromagnetic tripping & //bid details 2 / 28