Web Analytics Made Easy - StatCounter

Apff Panel Tenders

Get complete information related to latest Apff Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Apff Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Apff Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45546255 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45743718 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45726505 Due date: 20 Jul, 202620 Jul, 2026 45.00 Lacs
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep

CTN :45478137 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : items - computer and servises and otheres, mcb (miniature circuit breaker), acb (3200a/4000a ), acb (air circuit breaker), allen key set, amf relay, ammeter, annunciation system, anti-corrosion spray, arc flash suit, arc flash suit (ht/lt panel ), auxiliary contacts, avr (automatic voltage regulator), battery charger, blower/air blower, breather assembly, bus coupler acb, busbar insulators, busbar supports, cable glands, cable glands, cable lugs, cable ties, cable ties, changeover switch, clamp meter, clamp meter, combination pliers, consumables, contact cleaner spray, contactor, continuity tester, control cable, control fuses, control relay, control wires, cooling fan, copper busbar, crimping tool, ct (current transformer), current transformer (ct), dg set synchronization panel (3 750 kva), digital multimeter, digital multimeter, discharge rod, earth fault relay, earth switch, earth tester, earthing rod, electrical contact cleaner, electrical gloves (11 kv rating), electrical safety gloves, emergency stop switch, energy meter, engine control module, face shield, ferrules, ferrules, flexible wire, frequency meter, fuse fuse base, heat shrink sleeves, heat shrink tubes, hrc fuse, hrc fuses, ht protection relay, indicator lamps (r/y/b), infrared thermometer / thermal camera, insulated screwdriver, insulation tape, isolator switch, lightning arrester, load sharing module, lockout-tagout (loto) kit, loto kit, lt pcc/mdb panel, lubricant spray ( ), lugs, maintenance tools, mccb, mccb (molded case circuit breaker), megger (insulation tester), megger 5 kv, microfiber cloth, motorized mechanism, multifunction meter, multifunction meter, nose pliers, numerical protection relay, oti (oil temperature indicator), over current relay, overload relay (olr), phase sequence meter, phase sequence tester, plc module, power analyzer, power cable, power factor meter, protection & metering, pt/vt (potential transformer), push buttons (start/stop), pvc insulation tape, reverse power relay, rust remover, safety equipment, safety goggles, safety helmet, safety helmet, safety shoes, safety shoes, screwdriver set, secondary injection test kit, selector switch, shunt trip coil, side cutter, silica gel, smps (power supply), soft brush, spanner set, speed governor module, spiral wrapping, spring charging motor, starting relay, synchronizing relay, terminal blocks, thermal camera, thermostat, timer relay, torque wrench, transformer buchholz relay, transformer oil, under/over frequency relay, under/over voltage relay, uv coil, vacuum cleaner, vcb (vacuum circuit breaker), voltage tester, voltmeter, wire markers, wire stripper, wti (winding temperature indicator), , , , comprehensive maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor & majour spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete., annual maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete.

State Government

CTN :45559047 Due date: 06 Jul, 202606 Jul, 2026 10.63 Lacs
Tender For corrigendum : supply, erection, testing and commissioning of diesel generator set 58.5kva diesel generator set, rated at 58.5kva, 415v, 0.8pf, mounted on a base frame, complete with inbuilt fuel tank and battery 1 no. 12v and inbuilt standard manual control panel with acoustic enclosure nal approved diesel generator set 58.5 kva capacity with amf panel as per specification at 220 6611kv rs somanahalli in operation division somanahalli, bengaluru

State Government

CTN :45699085 Due date: 25 Jun, 202625 Jun, 2026 86.44 Lacs
Tender For supply, installation, testing and commissioning of 400 kva, 3 phase, 415v water cooled silent type diesel generator set including all accessories with amf control panel at pandu pokhar - rajgir and papharni talab - mandar, banka.

CTN :45690396 Due date: 02 Jul, 202602 Jul, 2026 25.59 Lacs
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &

Central Government/Public Sector

CTN :45697889 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For tender for supply of supply, installation , testing and commissioning of 58.5 kva diesel generating sets, three phase, 415v with amf control panel type of engine cooling :liquid cooled, rated rpm of engine(rpm): 1500, type of alternator : brushless, class of insulation: h,battery capacity(ah) : 120 , no of batteries: 1 or more,cpcb-iv+ emission norms,insulation classclass-h,starting system-electric start,standardscpwd specifications, wr approve make list attached. supply and commissioning of battery operated platform truck, load capacity-4000 kg. make/model :-josts / godrej / voltas / jaldoot or equivalent. hand operated pneumatic barrel pump, dual directional pump of inlet 01 inch, deliver 05 liters in 20 turn, wetted components steel, cast iron, nbr, complete with 01 nos 2meter long flexible delivery pipe. suitable to barrel capacity 210/220 liter brand: prachand, lubi, toss, kingom, lavaka, skope, (detailed description/specification as per product # 1 of gem contract no. gemc-511687710211457 dt.19/04/2026 , two wheeler tyre with tube (bullet motorcycle) size 110/90-18 m/c 61p and 90/90-19 m/c 52p brands like mrf, ceat or similar. tyre with tube for mp-43-g-1645 vehicle model no. 215/75 r15 make/brand : ceat, jk, mrf or as similar. tyre with tube for bullet motorcycle size-(90/90-19 m/c 52p), make-mrf. steel radial tyre with tube for departmental vehicle make- mrf/apollo/ceat only with warranty as per manufacturer and enclosed annexure-l - 1. ashok leyland dost tyre size 185 r14 (185mm section width for a 14-inch rim). steel radial, ply rating-10pr, for 02 vehicles with stepney. 2. mahindra maxx, tyre size7.00 r 15 (7.00 inch section width, 15-inch rim diameter). steel radial, ply rating-12pr, for 01 vehicle with stepney. 3. eicher truck, tyre size 8.25-20 (20-inch rim diameter) steel radial, ply rating-16pr, for 01 vehicle with stepney.

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

Central Government/Public Sector

CTN :45329483 Due date: 29 Jun, 202629 Jun, 2026 12.61 Lacs
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
 Loading, Please wait...

Connect us via What's Up