Get complete information related to latest Arching Horn Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Arching Horn Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Arching Horn Tenders.
Tender For corrigendum : maintenance of electrical installation and fans, power plugs and street compond light and repair maintenance of sub-station equipments stand by 320 kva diesel generator set pump set for water supply, wet riser i/c sprinkler system, automatic fire alarm, pa and sound system in ccras building at janakpuri, new delhi (sh: ei work in basement and ground floor, cctv work, chimney work in canteen area at 2nd floor)
Tender For providing of repair and overhauling service - multifunction machines mfm; diesel generator set 75kva kirloskar with sound proof enclosure; yes; buyer premises
Tender For repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For corrigendum : supply of archinghorn , al. clamping ring , weaving tape 25 mm x 50 meter , cotton tape 1inch x 25 meter , clamping member aluminium casting with ms hexagonal nut , silica gel breather 250 gram
Tender For supply of archinghorn top & bottom with copper shunt as per rdso specification drg. no. skel 4384. for cht. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For stage/rate contract for supply of key material/equipments required for operation/maintenance of 33kv lines and 33/11-6.6 kv receiving stations valid for the financial year 2026-27 or till finalization of next stage contract - power transformers, supply of transformer oil as per is: 335-1993 with latest amendments thereof, supply of buchhloz relay for 33/11-6.6 -6.6 kv transformer protection (10mva / 6.3 mva/ 5mva) as per is 3637:1966, supply of winding temperature indicator (wti) for 33/11-6.6 kv power transformer (10 mva / 6.3/ 5 mva ) as per relevant is 5561 standard., supply of oil temperature indicator (oti) for 33/11-6.6 kv for power transformer (10 mva / 6.3/ 5 mva )as per relevant is 5561 standard., supply of cork sheet 6 mm as per relevant is 5561 standard., supply of old sarees/dhoti cloth, supply of gaskets suitable for power transfomers, 33kv ct&pt, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bush rods with copper washers as per relevant is 3347 standard., hv side, lv side, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bushes as per relevant is 3347 standard., hv side, lv side, supply of 11 kv spout bushes (indoor type) conforming to relevant standards ammended up to date, supply of mechanical plunger (conforming to relevant standards ammended up to date ) for, 11 kv breakers (both incoming & outgoing), 33 kv vcbs both indoor & outdoor type, supply of 11 kv partition insulators/ bushes with inbuilt studs of required size conforming to relevant standards ammended up to date as per directions of site engineer, supply of dc connector for 11 kv panels conforming to relevant standards ammended up to date, supply of breather conforming to latest is 3202 (ammended up to date) for 10mva/ 6.3mva/ 5/ 3.15 mva., supply of silica gel as per is :3202, supply of o-ring oil sealing of sizes for power transformer bushes (hv/lv) as per is 3202., supply of galvanised iron angle/channel/flat per is :2062 grade "a" of sorts and sizes, g i channel 100x50x50x6 mm, g i channel 75x40x40x6 mm, g.i angle iron 65x65x6 mm, g.i angle iron 50x50x6 mm, g.i flat iron 40x6/ 50x6 mm, supply of archinghorns (set of three pieces) for power transformer, supply of g.i bolt full thread of sorts and sizes with washers and nuts of different sorts and sizes, supply of 33kv current transformer (3-core) of reputed make,outdoor oil cooled, single phase (comprising of 3 no.) (as per is 2705 -1992 having ratio of is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2010), 400-200/5-5-5 a, 300-150/5-5-5 a, 250-125/5-5-5 a, 200-100/5-5-5 a, supply of 11 kv c.t.(2-core/3-core) of reputed make suitable for 11kv vcb panels (comprising of 3 no.) as per is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2003) having ratio:-, 800-400-200/5-5a, 750-375-187.5/5-5a, 600-300-150/5-5a, 400-200-100/5-5a, 200-100/5-5a, 150-75/5-5a, 100-50/5-5a, 50-25/ 5-5a, 33kv and 11kv outdoor type potential transformer, supply of 33kv potential transformer (comprising of 3 no.) of ratio 33kv/ 3 / 110v / 3 ,single phase,outdoor oil cooled, dead tank type pt as per is:3156 -1992, supply of 11kv potential transformer 11kv/ 3 / 110v / 3 three phase box type (combo unit) as per is :3156-1992, supply of 11kv potential transformer (comprising of 3 no.) 11kv/ 3 / 110v / 3 single phase seperate type as per is :3156-1992, 11kv and 33kv vcbs, supply of master trip relay 24-50 v rel 615 abb ied suitable for 11kv vcb switch gear panels (compitable for electric feild, pascal, scheinder, abb, essan l&t or any other equilant make), supply of digital protection relay adr 141c, rel 615 /abb ied,model no. er113 2 o/c + 1 e/f with high trip (mit113), auxiliary voltage = 0-36 volt conforming to iso 9001:2008 standards (compitable for electric fe