Web Analytics Made Easy - StatCounter

Argo Shield Gas Tenders

Get complete information related to latest Argo Shield Gas Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Argo Shield Gas Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Argo Shield Gas Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

CTN :45720895 Due date: 01 Jul, 202601 Jul, 2026 25.00 Lacs
Tender For annual rate contract for annual maintenance and spare parts supply work of jcb machines. - cylinder liner, over haul gas kit, valve inlet exhaust, crank shaft, main bearing set, trust washer, piston, piston ring set, diesel main pipe, diesel filter pipe, thermo state elbow, air cleaner hose, diesel pump repair with parts, thermo state valve, connecting rod, con. rod bearing set, cam shaft bush, rocker arm, rocer arm shaft, gear cam shaft, water pump assy., oil pump assy., oil filter, belt, engine mount pad, exhaust elbow, engine throttle cable, engine stop cable, turbo charger assy., silencer exhaust abi, flang exhaust, element main, element secondary, auto tensioner, idler gear, engine fan, fuel filter assy., filter kit, engine connecting rod, fan drive puley, hyd. strainer, suction strainer, fuel injection pump, injector pipe, rubber hose, fuel filter assy., nozzle, return line, fuel module with sensor, fuel tank cap, fip repair with parts, radiator, radiator assy., coolent, hose top, hose cac (cold side), hose cac (hot side), radiator solding, front grill, front grill lock, front wheel and axle, axle service, center pin, axle stub, hub, hub stud, hub seal, seal cone, bearing inner, bearing outer, axle carrior l/h, axle carrior r/h, track rod, brake fri. plate, brake cou. plate, brake seal, brake oil 500ml, differential, differential gear planet, gear planet, bearing roller double, seal cassetle, bearing teper, tripling seal, stud wheel, carrior innulus, gear innulus ring, hub palentry, drive shaft, bearing roller, bearing teper roller, yoke, cross patti & bolt, cross holder, uj cross, bearing, brake, master brake cylinder, pipe brake l/h, pipe brake r/h, brake reserver, steering, coupling, bearing, rim steering wheel, self starter, self starter, solenoid, switch altinator, altinator puley, wheel belt 1232, rocker plate, field set, armature bush set, bearing assy., carbon set, bendex, armature, armature bush set, altenator, starter, cut out, rectifier plate, bearing, bearing plate, rotor, terminal, wiring and electrical, wiring harness complete, bettery cable, hour meter, head light bulb, tail light bulb, fuse and reley 15 amp, tail lamp, head light assy., ignition switch, wiper blade assy., harness roof, combination switch, fog lamp, body, side mirror, seat, wiper motor assy., wiper blade, catch window, latch l/h, wind screen front, glass outer l/h, glass outer r/h, rear window glass, door soccker, door hinge, lock set inner, lock set outer, door got set, door belt, transmission, transmission over, charging pump assy., counter plate, firction plate, transmission filter, bearing, bearing, torque converter, bearing, converter, drive plate kit, mounting, yoke coupling, lever assy. gea turret, selonoid valve assy., strainer, transmission filter, stabliser, steblizer piston, steblizer rod, inner leg steblizer, steblizer foot, pin pivot, adjuster, atb rear pad kit lower, atb rear pad kit upper, hydraulic, ind. steering suct, selonoid coil, hyd. filter assy., hyd. filter element, mrv, hyd. pump, repair kit, priority valve, ram seal, pump seal kit, pump steering, ramp bucket, ramp bucket, ramp bucket, ram, bucket lift cylinder ram, bucket tilt cylinder ram, boom ram, loader ram, loader jaw ram, dipper ram, slew cylinder ram, stablizer ram, steering cylinder ram, 6 in 1 ram, hose, hose-10-bsp 560mm, hose-08-bsp 1860mm, hose-10-bsp 2750mm, hose-04-10bsp 1825mm, hose-08-bsp 2620mm, hose-10-bsp 2520mm, hose-08-bsp 2860mm, hose-08-bsp 2650mm, hose-12-bsp 3900mm, pin and bush, bucket pin, pin, pin, tipping lever, pin dipper, bush, bush, pin, boom main pin, pin, pin top, pin pivot, pin pivot, pin boom ram, pin pivot, pin pivot, pin pivot, kpc kit and bush, bucket kit, seal kit, bucket seal kit, dipper seal kit, boom seal kit, seal slew kit, s t b, steering seal kit, loader seal kit, lift seal kit, bucket seal kit, rubber seal kit, boom seal kit, s t b kit, slew seal kit, loader seal kit, steering seal kit, loader and bucket welding, l

CTN :45478155 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : cs/rmo/2026/2089-90/ac/washing - items, ac compressor 1-5 ton, ac compressor 2 ton, ac outdoor gas bal, ac indore fan motor, ac outdoor fan motor, ac condensers, ac gas charging, ac condenser outdoor mesh, connector ac, ac sensor indore, ac running capacitor, ac service charge, water cooler fan motor, water cooler compressor, water cooler condenser, water cooler mash, water cooler riley, water cooler over load, water cooler running capacitor, water cooler service charge, water cooler gas filling charge, washing machine spine timer, washing machine wash timer, washing machine wash motor, washing machine spine motor, washing machine bello, washing machine gear box, washing machine capacitor, washing machine service charge, refrigerator compressor, refrigerator rile, refrigerator overload, refrigerator thermometer, refrigerator senseor, refrigerator wall, refrigerator fan motor, refrigerator bimetal, refrigerator time, refrigerator pcv, refrigerator fuse, refrigerator door swath, refrigerator gas charge, refrigerator service charge, ac pcv, ac stand for spilit ac, ac stand for window ac, copper pipe for spilit ac per feet, copper pipe for window ac per feet, spilit and window ac remote

CTN :45714317 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of cassette and split ac c c - cassette ac split ac , itc of ac , copper pipe, electrical cable, drain pipe , ms stand, indoor brackets, gas charging , ventilation work

CTN :45712200 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of required materials & spare for rectification in pac units at haldia lpg import terminal - refrigerant gas r-407c, drier, filter, r410a, dml 305, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, nitrogen cylinder, 02 use, for gas charging, da use, for gas charging, multiple leakage rectification in pac outdoor units along with brazing and transportation of cylinders, display, small, icom, 180633g3r0 for air conditioning machine, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810

Central Government And Public Sector

CTN :45592924 Due date: 01 Jul, 202601 Jul, 2026 3.73 Lacs
Tender For bid to ras supply of replacement of rotary compressor , replacement of indoor blower fan motor , replacement of outdoor unit motor , replacement of pcb control unit , carrying out leak test and gas charging , shifting and reinstallation of outdoor units , sf 0.5 inch copper refrigerant pipe , sf 0.25 inch copper refrigerant pipe

corporations/Associations/Others

CTN :45712936 Due date: 13 Jul, 202613 Jul, 2026 19.20 Lacs
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor

CTN :45506168 Due date: 15 Jul, 202615 Jul, 2026 2.26 Crore
Tender For corrigendum : tender for supply of temperature sensor-transmiter tt 001 hbs-5-4425-1 , temperature sensor/transmiter tt 001& 2 hbs-5-4425-2 , temperature sensor tt 002 hbs w/o no 64032 , temperature transmiter tt 002 hbs w-o no 64032 , carbon brushes 59 kw , bearing set 59 kw nu215 &nup215 , isolator switch 3 pole 25a , programmble controller , heating element , motor 22kw1138 , humidistat1163 , main switch ot80f31226 , ovrld gv3l501234 , pressure switch1980 , differential pressure switch adps03 50-500 pa , differential pressure switch adps05 200-1000 pa , differential pressure switch adps07 1000-4000 pa , actuator gga326.1 e-ha 230v , ac-dc converter 24v 5a , main switch ot63f3 , main switch ot100f3 , main switch ot125f3 , overload relay gv2-p16 9-14 a , overload relay gv2-rt08- 2.5-4 a , terminal connector 2 , 5 mm2 , terminal connector 4 mm2 , terminal connector 6 mm2 , terminal connector 10 mm2 , terminal connector 16 mm2 , terminal connector 25 mm2 , hmi display 7inch x2 pro new type , hmi cable cab 103-3m , plc module fx3u-485-adp-mb rs485 , actuator , pressure meter for citadel , compressor-motor flexible coupling insert 61-0920 , compressor rt450al-oil filter replacement kit 61-9916 , gasket copper-1-4inch flare , fan belt , dust filter , nbc cart stanag 44471157 , filter1414 , filter1424 , filter1430 , filter1436 , filter1442 , filter1448 , fan bearing , impeller1042 , filter2188 , filter2189 , filter2192 , filter2194 , motor bearings drive end type 6309 , motor bearings non drive end type 6204 , motor bearings non drive end type 6208 , motor bearings non drive end type 6210 , motor bearing plummer block 0048 , motor bearings - block blns0050 , motor bearings - block blns0030 , 2 stage combi g4 pre filter and f9 fine filter 600 m-3h , 2 stage combi g4 pre filter and f9 fine filter 900 m-3h , 2 stage combi g4 pre filter and f9 fine filter 1800 m-3h , 2 stage combi g4 pre filter and f9 fine filter 2700 m-3h , 2 stage combi g4 pre filter and f9 fine filter 3600 m-3h , flexible hose 50mm nb , flexible hose 65mm nb , flexible hose 100mm nb , flexible hose 25mm nb , flexible hose 32mm nb , flexible hose 25mm nb , flexible hose 32mm nb , thermostatic expansion valve body , replacement motor , replacement motor , compressor tool kit xjf 95s , gas charging hose , tempreture humidity meter
 Loading, Please wait...

Connect us via What's Up