Get complete information related to latest Armoured Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Armoured Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Armoured Cable Tenders.
Tender For supply of 50 pair pijf cable 0.63mm copper conductor armouredcable make: usha martin or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supplying electrical materials and repair maintenance services for street lights and electrical works at. grampanchayat somatane - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armouredcable 4core 6sq mm, supplying & laying pvc armouredcable 4core 10 sq mm, supplying & laying pvc armouredcable 2core 10 sq mm, supplying & laying pvc armouredcable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunk
Tender For s/f of 07 nos. 9.50 mtr. long tower pole alongwith 10 sqmm 2 core armouredcable, led flood light fitting etc. at m.g. college tiraha, dav inter college chauraha, adarsh vyayamshala tiraha, bhagwatdas ghat chauraha, phoolbagh mandi chauraha, bairister sahab residence and dso tiraha civil lines, ward-78, zone-01, kanpur.
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-delta starter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe
Tender For s/f of 08 nos. 9.50 mtr. long tower pole alongwith 10 sqmm 2 core armouredcable, led flood light fitting, automatic switches etc. at murari atta chakki park, chitra kda colony park, tikona park, hanuman mandir park, naseem pathan park, durga park, vivekanand park, amit gupta niwas park, ward-87, zone-03, kanpur.
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For maintenance of point wiring, old unsv fan and geysers, db and light fittings with other connected items in otm and md accn at ghatkopar and vikhroli area under ge (n) santacruz mumbai - supply & fix including taking down sub main wiring with two run of 06 sqmm stranded copper conductor frls wire with one run of 06 sqmm stranded copper conductor as earth continuity conductor connected to common earth dolly including pvc fr heavy duty conduit of adequate size for housing the wires from main db to spn db complete all as specified directed by engr in charge. note: two runs of 06 sqmm cable and one run of 06 sqmm cable with pvc conduit shall be measured as one length. make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for sub main wiring with two single core 04 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty, isi marked of suitable size for sub main wiring including 04 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- two runs of 04 sqmm copper conductor cable, one run of 04 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for three phase sub main wiring with 4 single core 10 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty of adequate size, isi marked, not less than 25 mm dia for sub main wiring including 10 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- four runs of 10 sqmm copper conductor cable, one run of 10 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, frlsh, passing through pvc casing capping/pvc conduit including all fittings and accessories for mounting of switches & sockets as required at site along with one run of pvc insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) frlsh as earth wire connected to earth dolly complete all as specified & as directed by engr-in-charge for one light point/ exhaust/wall/ceiling fan controlled by one switch.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit/ pvc capping-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, all as per item no.4 above but one bell point controlled by one bell push., all as per serial no.4 here-in but for one light point controlled by two way switches (two way switch point wiring), all as per item no.4 but one 3 pin socket point 5 amps on independent board, all as per item no.4 but one 3 pin socket point 5 amps on same board, all as per item no 4 here-in-before but for one socket point 15 amp with 2.5 sq mm pvc unsheathed frlsh wire along with 2.5 sq mm green colour wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed., all as per item no 4 here-in-before but for point wiring on independent board with 4sqmm copper cable and provision of 4sqmm pvc insulated frls cable 1100 volts grade with