Get complete information related to latest Arms Cartridge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Arms Cartridge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Arms Cartridge Tenders.
Tender For supplying, installation, testing and commissioning of machines and equipment for civil engineering department at ttaadc polytechnic institute, khumulwng, west tripura for the project improvement of infrastructure in ttaadc polytechnic institute, kh - supplying, installation, testing and commissioning of machines & equipment in civil engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education departmen.", computerized universal testing machine, 6 pillar type, for conducting tests on various types of ferrous and non-ferrous materials; consisting of-loading unit 600 kn capacity, hydraulic jaws and pumping system, clamping jaws for round specimens, clamping jaws for flat specimens, pair of compression plates,for compression test, rollers of 160 mm width and 30 mm diameters, for transverse test, bending table stopper, allen keys, spanners,double shear test attachment, bend rebend test attachment, electronic extensometer., steel bar cutting machine, vernier caliper, stainless steel ruler, 1m length, mixer machineriesconcrete mixerthe counter balanced mixing drum is easy to tilt two cubic feet mix capacity. total drum volume is 3 cubic feet.. suitable for operation on 220 volt single phase, 50 cycle, a.c. supply, isi cube mouldcube mould, with base plate : as per is : 516 with isi mark cube mould, 15 cm x 15 cm with base plate (made of cast iron - isi mark), cement mortar cube mouldcement mortar cube mould cube mould, 7.06cm x 7.06cm with base plate (made of mild steel), vibrating machinevibration machine with timer : is : 4031 this apparatus is suitable for making cubes of 70.7 mm. for mortar strength evaluation. the mould is mounted on a vibrating platform with a frequency of 12,000 400 vibrations per minute. to the platform are attached four matched springs. the whole assembly is operated by a revolving shaft with an eccentric mechanism. the machine is supplied with a timer, a switch mounted on a steel panel and a 70.7 mm. steel cube mould with a base plate., electronic balancecapacity 500gm, 0.01 gm accuracy, electronic balancecapacity 5kg, 0.1 gm accuracy, electronic balancecapacity 20kg, 0.5 gm accuracy, electronic balancecapacity 100 kg, 10g accuracy, air permeability apparatus (blaine type)isi certification mark is;5516, fitted in aluminium box, vibrating tablevibrating table for compaction concrete cube, cylinders the table deck size 50 cm x 50 cm and has stops along its edges to prevent moulds from walking off the table during vibration the variably pitch pulley arrangement permits the frequency to be varied sleeplessly between a maximum of 3600 vibrations per minute a speed regulation handle is provided for increasing or decreasing the frequency. the vibrating deck. a switch is provided for starting the motor. operation on 440 volts, three phases, a.c. supply. table top - 50 cm x 50 cm, curing tankwater curing bath with agitation system digital indicator for temperature * 24- hour cycle from time of mixing * controlled 100 c +/- 2 c. temp. for concrete * controlled 27 c + 2 c curing temperature for grey cement the tank has been designed to accommodate 150 mm / 70.6 mm casted cubes up to 12/24 cubes and fully insulated. complete with a hinged lid, heated, thermostat and recirculation pump. provision of two removable racks allowing free circulation of water around each cube. the pump, drain valves and electrical equipment are housed in a compartment located at one end of the tanks. the tank is heated by an immersion heater under normal conditions and refrigeration system for grey cement, the temperature is controlled at 35deg.c. +/- 2 deg.c, for about 15 minutes after immersion of the freshly-made specimens. curing tank for 12 moulds of 150mm/24 moulds of 7.06mm, vicat apparatus boxwith isi certification mark, is:5513, fitted in aluminium, le-chatelier mouldwith
Tender For corrigendum : supply of digital radiography system type c (qty:10) - digital radiography system 50kw ceiling suspended type, single detector with all accessories as per specifications except the following, x-ray table 6 way floating table, dry imager with 2 online trays, additional detector (rate fixed for three years from the date of price bid opening), light weight lead apron with thyroid gaurd, additional workstation, x-ray trolley table (not taken for evaluation), x-ray table four way (not taken for evaluation), x-ray view box double film (not taken for evaluation), cost of one viewing station (hardware) with necessary software and ups (not taken for evaluation), fully automated full length image stitching on table and vertical bucky necessary hardware and software (not taken for evaluation), 15.12.2:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area beyond 3 sq. metres, 15.12.1:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area 3 sq. metres and below, 15.23.1:dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm, 15.3:demolishing r.c.c. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of engineer -in-charge., 15.57:dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by engineer - in-charge, 15.7.4:demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar, 15.60:disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved, 2.1.1:earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:all kinds of soil, 50.2.25.1:filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site engineer-in-charge, 2.34.1:supplying chemical emulsion in sealed containers including delivery as specified.chlorpyriphos / lindane emulsifiable concentrate of 20%, 2.35.1.1:diluting and injecting chemical emulsion for post -constructional anti-termite treatment (excluding the cost of chemical emulsion):along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:with chlorpyriphos /lindane e.c. 20% with 1% concentration, 50.4.1.1:providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc., 50.5.33.2:providing and laying in position machine batched and machine mixed design mix m-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the
Tender For corrigendum : supply of digital radiography system type b (qty:10) - digital radiography system 80kw ceiling suspended type, single detector with all accessories as per specifications except the following, x-ray table 6 way floating table, dry imager with 2 online trays, additional detector (rate fixed for three years from the date of price bid opening), light weight lead apron with thyroid gaurd, additional workstation, x-ray trolley table (not taken for evaluation), x-ray table four way (not taken for evaluation), x-ray view box double film (not taken for evaluation), cost of one viewing station (hardware) with necessary software and ups (not taken for evaluation), fully automated full length image stitching on table and vertical bucky necessary hardware and software (not taken for evaluation), 15.12.2:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area beyond 3 sq. metres, 15.12.1:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area 3 sq. metres and below, 15.23.1:dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm, 15.3:demolishing r.c.c. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of engineer -in-charge., 15.57:dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by engineer - in-charge, 15.7.4:demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar, 15.60:disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved, 2.1.1:earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:all kinds of soil, 50.2.25.1:filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site engineer-in-charge, 2.34.1:supplying chemical emulsion in sealed containers including delivery as specified.chlorpyriphos / lindane emulsifiable concentrate of 20%, 2.35.1.1:diluting and injecting chemical emulsion for post -constructional anti-termite treatment (excluding the cost of chemical emulsion):along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:with chlorpyriphos /lindane e.c. 20% with 1% concentration, 50.4.1.1:providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc., 50.5.33.2:providing and laying in position machine batched and machine mixed design mix m-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the