Tender For corrigendum : invitation to bidforsupply of cooling tower water treatment chemical satgppcs 702 mw combined cycle power plant at village kovaya, near pipavav, tal. rajula, dist. amreligujarat, india
Tender For corrigendum : tender for the supply of water treatment chemicals - cooling water & boiler water treatment chemicals, corrossion inhibitor for cooling water treatment, bio-dispersant for cooling water treatment, mineral dispersant for cooling water treatment, antiscalent for cooling water treatment, antifoulant for cooling water treatment, non oxidising biocide-1 for cooling water treatment, non oxidising biocide-2-45% glutaraldehyde, chemical for clo2 generation, chlorine for clo2 generation, caustic soda for cooling water treatment, anti scalant, corrossion inhibitor & sludge conditioner for boiler water treatment, oxygen scavenger for boiler water treat ment, condensate line protection for boiler water treatment, feed water ph booster (volatile) for boiler water treatment, contingency chemicals for cooling water treatment. this will not be considered for financial evaluation, hydrocarbon ingress into system, chlorination failure, ph fluctuation, lube oil/ grease ingress in to system, high iron content, high turbidity of make up water, high chloride in make up water
Tender For corrigendum : supply of cooling water treatment chemicals along with treatment monitoring and operation of the cooling tower and operation of fire water pump house at the oxo acrylate complex dumad gujarat refinery vadodara.
Tender For supply of analysed oil samples and disposal record , boiler water analysis record , calibration record, carbon analyzer , calibration record, flame aas , calibration record, analytical balance , calibration record, mass spectrometer , calibration record, weight box, e1 , calibration record, gc, mp , calibration record, ion chromatograph , calibration record, kf titrator , calibration record, ftir , calibration record, conductivity meter , cooling water analysis record, landscape , calibration record, density meter, dma 58 , density meter calibration record , dissolved oxygen record , dm plant cpp analysis record , dm plant analysis record , calibration record, flame photo meter , calibration record, h2s gas bombs, ss sample containers , lab effluents discharge , monthly report for trade effluents , na2so4, recovery analysis record , ng heavy water analysis record , non returnable material dispatch record , oxygen 18 sample analysis record , observation book for kmno4 demand , pc and al analyzed samples disposal record , calibration record, ph meter , process liquids analysis record , raw material analysis record, h2so4 , raw material analysis record, naoh , raw material analysis record, na2s and nahs , raw material analysis record, hci , raw material analysis record, alum , raw material analysis record, libr , raw water treatment plant analysis record , rcu gas analysis record , seal and lube oils analysis record , system and purge gas analysis record , calibration record, turbidity meter , uv visible observation book , waste stripper average record , xu samples analysis record , bottom ash analysis record , boiler feed, dissolved oxygen, iron and copper record , flue gas analysis record , scc ltd. coal analysis record , spm analysis record , single ruled book
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For providing of customized amc/cmc for pre-owned products - --; --; two years comprehensive cooling water treatment for pfbr induced draft cooling tower idct with detailed specification as per annexure-a..
Tender For corrigendum : providing of service for chemical treatment of cooling water - glycol water treatment; glycol water treatment; contracts for supply of glycol water treatment chemicals