Tender For providing of customized amc/cmc for pre-owned products - --; --; comprehensive maintenance contract (cmc); not applicable; yes - large display , video conferencing system , camera 4k mptz with 12x optical zoom , high−quality matrix with eight hdmi inputs independently routable to eight hdmi outputs , digital signal processor , 4" - 8" coaxial in-ceiling loudspeaker with 30 watts continuous, 120 watts peak power, 8 ohms, en54-24:2008 certified ,70v/100v: 25 w/ 12.5 w/ 6.3 w , high-performance control processor with a powerful 4-series , 24-28 x 10/100/1000 mbps port network switch lan ports for high-speed wired connection with plug & play there’s no configuration hassle quality of service , aar key 10 kva ups amc charges
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-434 construction of icgs murud janjira at dighi port; repair of hull jobs sl no h-56, h-57, h-58, h-59, h-60, h-61, h-62; service provider
Tender For corrigendum : providing of repair and overhauling service - diesel generators- dg sets (dfm); port da make caterpillar; no; buyer premises, service provider premises
Tender For providing of assets insurance service - terrorism insurance, marine – cum – erection (mce), fire insurance, port package, marine hull; property damage cover, standard fire & special perils cover, business interruption (loss of profit) cover, terrorism cover, eart..
Tender For providing of repair and overhauling service - installation new fwd anchor capstan port stbd and degutting of existing fwd anchor capstan port stbd in ship; any other suitable brand; no; buyer premises
Tender For providing of repair and overhauling service - repairs/servicing of ip based cctv dome/bullet camera; panasonic; yes; buyer premises,repair and overhauling service - repair /servicing of ip based cctv ptz camera; panasonic; yes; buyer premises,repair and overhauling service - repair /servicing of 40 ch network video recorder; panasonic; yes; buyer premises,repair and overhauling service - repair /servicing of 32 ch network video recorder; panasonic; yes; buyer premises,repair and overhauling service - repair /replacement of 9u rack; na; yes; buyer premises,repair and overhauling service - repair /servicing of 43 inch display monitor; samsung/ lg/ panasonic; yes; buyer premises,repair and overhauling service - repair /servicing of 24 port giga poe switch with 2 sfp port; na; yes; buyer premises,repair and overhauling service - repair /servicing of 8 port giga poe switch with 2 sfp port; na; yes; buyer premises,repair and overhauling service - repair /servicing of 4 port giga poe switch with 2 sfp port; na; yes; buyer premis
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; installation of ncn port with cable; service provider
Tender For corrigendum : supply of procurement of spares and service part of 10 yearly overhauling of generator circuit breaker c c -contact aux ch part no hbl956327001 , kit c m chambre auxiliaire avec clapets part no hbl956327102 , seals for station contactandauto bl valve part no hbl956328001 , parts for station contactandauto bl valve part no hbl956328101 , seals for insertion resistor part no hbl955518001 , seals for locking valve part no hbl956333001 , seals for ctl valve openingandclosing part no hbl957148001 , kit pieces valve de commande ch auxil part no hbl957148102 , seals for enclosure part no hbl957422003 , seals for check valve part no hbl955939001 , seals for venting valve of muffler part no hbl955814001 , seals for inspection port hole part no hbl956021001 , seals for pneumatic ctl cubicle part no hbl957504001 , valve part no hbl271408003 , parts for ctl pneumatic relay and its receive part no hbl956430101 , seals for pneumatic block part no hbl955777002 , parts for pneumatic ctl block part no hbl955777101 , seals for standard electrovalve part no hbl955778001 , parts for standard electrovalve part no hbl955778101 , switch part no hbl 02555811 , switch part no hbl 02555809 , filter part no hbl956872001 , o ring part no hbl 02445261 , o ring part no hbl 02445267 , valve part no hbl272595001 , set of valve diam 18 for pneum block part no hbln55042701 , parts for auto bleeding valve part no hbl957798101 , seals for close checking sw and ctl device part no hbl955697001 , complementary consumable kit part no hbkitpdr 1 grease si33 part no hbl 01835217 qty 2 nos , 2 vaseline grease 80 gr part no hbl 01835106 qty 10 nos , lock washer kit , set of springs , set of springs for order valves , additional spares part , seals for auto bleeding cabinet part no hbln55132401 , set of seals automatic bleeding part no hbl957798002 , servicing of 10 yearly overhauling of gcb type pkg2v scope of job attached servicing to be completed within 30 days after start of job
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-146; e22 port da exhaust pipe lagging deteriorated and perished defect to be rectified by renewing the lagging with glass wool insulation and proved for satisfact..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-146; h12 engine room and water jet compartment chequer plates oxidized due to fair exposure to sea water and persisting conditions resulting in loss of protective..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-146; h13 following minor defects observed and same may be repaired replaced renewed; service provider