Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For supply of complete shutter assembly with bearing shaft and holding work. , limit switch , bearing with block, block for basket , load bucket cylinder , bag clamp cylinder , back welding clamp 50 mm , back welding clamp 40 mm , rod and bearing with rod. , coarse feed cylinder , fire feed cylinder , frl size 1 upon 2 inch , pneumatic grl 1 upon 4 inch x 8 mm , pipe 8 mm , ss load cell below type mettler to ledo 400 kg , complete repair kit for cylinder 40 x 100 , complete repair kit for cylinder 50 x 100
Tender For bid to ras supply of led batten light (led tube light) (v2) (q2) , led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , plastic bib taps, pillar taps, angle valves & stop valves for hot & cold water services conforming to is 9763 (q3) , copper alloy taps/stop valves (v2) conforming to is 8931 (q3) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , astronomicaltimeswitch based on lux level , bell ding dong call bell , bell push 6 amp piano type , cable lugs alumn 120 sqmm , cable lugs alumn 150 sqmm , cable lugs alumn 185 sqmm , cable lugs alumn 25 sqmm , cable lugs alumn 35 sqmm , cable lugs alumn 50 sqmm , cable lugs alumn 95 sqmm , cable pvc insulated copper single core 2 point 5 sqmm , cable pvc service al 2 core x 10 sqmm , cable pvc service al 2 core x 4 sqmm , cable pvc service al 2 core x 6 sqmm , mcb sp 25 amps , mcb 4 pole 40 amp , mccb 100 amps 4 pole 25 ka , mccb 200 amps 35 ka 4 pole , mccb 250 amps 35 ka 4 pole , ht 11 kv heat shrink straight through jointing kit for cable 95 sqmm , booster pump 1 hp single phase , cable copper 25 sqmm single core , cable copper 35 sqmm single core , cable copper 50 sqmm single core , lugs copper 25 sqmm , lugs copper 35 sqmm , lugs copper 50 sqmm , lugs copper 70 sqmm , flat copper cable 10 sqmm 3 core for submercible , flat copper cable 6 sqmm 3 core for submercible , mcb 4 pole 63 amp c series , hrc fuse 100 amp with copper lever , hrc fuse 200 amp with copper lever , ht cable end joint heat shrink outdoor of size 120 sqmm , ht cable end joint heat shrink outdoor of size 95 sqmm , ht 11 kv heat shrink straight through jointing kit for cable 120 sqmm , led bollard light 12 watt , led gate light 12 watt outdoor waterproof , led recessed luminer light 16 watt , led recessed mounted panel light 18 watt , power contactor 4 pole 70 amp , pvc insulated frlsh single core copper conductor 4 sqmm size , socket 16 amp flush type , socket 6 amp flush type , ht fuse element 11 kv voltage grade 10 amp , pvc tape roll 40 mm , led street light driver 45 watt , led street light driver 60 watt , on load change over switch 4 pole 40 amp with encloser , on load change over switch 4 pole 630 amp with encloser , mccb 400 amps 50 ka 4 pole
Tender For procurement of miscellaneous spares for mounting various actuators, solenoids, air limit switches, set of o-ring -- system ggsstp, ropar tender enquiry - grub screw with nut (ht) for mounting pd-28 actuator. size 10x40nim, nut bolt (ht) for mx-450 and cylinder body. size8x25 mm, dowel pin (ht for lock air cylinder assembly. size 10x50 mam, l-key bolt (cs) for air limit switch and cylinder. size 6x40mm., cylinder lock of esp and pd-15(cs). id-20mm and thickness imm, l-key bolt(cs) to lock the stopper of cylinder. size 6x30mm, actuator lock pd-28(cs), id-23mm and thickness-imm, actuator lock pd-50, pd-75 and cylinder lock of apη ducts(cs) id-33mm and thickness imm, l-key bolt for cylinder.6x40mm, screw with nut for mounting pressure switch. size(cs) 3x40mm., grub screw for mounting pd-50 & pd-75. size 12x50mm, nut-bolt(cs) for mounting electrical limit switch (4 to 7 fields). size 4x50mm., grub screw with nut (cs) for mounting electrical limit switches of pd-28, pd-50 & pd-75.size 4x25mm, nut bolt(cs) for mounting solenoids. suze 3x35mm, l-key bolt for air limit switch. size 3x40mm., l-key bolt(cs) for air limit switch. size 3x200mm, nut bolt (ht) for air limit switch. size 12x50mm., l-key bolt for air limit switch. size 4x35mm, l-key bolt(cs) for air limit switch. size 4x20mm, cylinder pin. drawing as perannexure-7, quick exhaust valve diaphragm of size 65mmdiameter thickness-2mm, material synthetic rubber, air limit switch o-ring of synthetic rubber., set consists of, size id-hom., thickness 2mm, 1.size: id = 1 , thickness 2mm, hsn code 40169320, screw with nutcs) 4x25 mm, nut-bolt (h.t) 12x25 for mounting mx-450, cylinder pin (160x250mm), drawing as per annex.-4, nut-bolt(h.t) 10x35 for coupling mx-450, l-key bolt(cs)(6x70mm) for poppet valve., diaphragm for quick exhaust valve diameter 6.5mm &thickness imm., cylinder spacer lock. drawing as per annex-2, stud for pd-28 mounting(10x12mm diameter-25 x40mm length(grub screw), stud(cs) for pd-50 and pd-75 mounting(12x14mm) diameter-10&75mm, stad gir pd-15 mounting(8x10mm) diameter-10x45mm length, hex nipple w(brass), hex nipple w"(ss), hex nipple "x3/4"(85), blow valve cup washer 100 nb drawing as per annex-6., blow valve disc 100 nb drawing as per annex-5, blow valve cup washer 50 nb. drawing as per annex.-1., blow valve disc 50 nb drawing as per annex.-3, stud with nun (cs) (8x35 mm) and overall 50mm length., vent filter sol viv top plate, drgas per annexure-8, solenoid valve rotex make" model 51400-6-20, solenoid valve repair kit
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; installation of new water resistance box; buyer- installation of new water resistance box for kec make motor 225 kw/300 hp, 978 rpm, motor amp - 387 amp. rotol volt - 400 star, rotor amp - 355, required control no & nc limit switch
Tender For corrigendum : supply of 1 or 4 inch solenoid valve for pneumatic cylinder 5 or 2 way , blow valve 50nb , seal kit for blow valve 50nb , repair kit for blow valve 50nb , pneumatic cylinder 4 inch x 9 inch , seal kit for pneumatic cylinder 4 inch x 9 inch , front clavish for 4 inch x 9 inch pneumatic cylinder , male connector 1 or 4 inch x pu-6 , male connector 1 or 4 inch x pu-8 , pressure switch seal pressure rt116 , pressure switch vessel low pressure rt112 , pressure switch vessel high pressure ips 70 , air limit switch , seal kit air limit switch , quick exhaust valve 3 or 4 inch , diaphragm for quick exhaust valve 3 or 4 inch , quick exhaust valve 1 or 4 inch , diaphragm for quick exhaust valve 1 or 4 inch , seal pressure gauge , vessel pressure gauge , pu tube 6mm , pu tube 8mm