Get complete information related to latest Atmosphere Glove Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Atmosphere Glove Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Atmosphere Glove Box Tenders.
Tender For corrigendum : special repair replacement of ultrasonic type water level indicator at water supply installations under age em of ge (west) ferozepur cantt
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For corrigendum : repair / maintenance of water level indicator and cleaning and painting of rcc over head reservoirs / ug sumps at ayodhya cantt under age(i) ayodhya
Tender For corrigendum : repair, maint and replacement of main pipelines, panels, cables, sluice valve, water level indicator, rewinding of pumpsets etc including allied works at zone b area of bagrakote mil stn under ge sevoke road
Tender For corrigendum : repair, maint and replacement of main pipelines, panels, cables, sluice valve, water level indicator, rewinding of pumpsets etc including allied works at zone a area of bagrakote mil stn under ge sevoke road
Tender For tender description : special repair to jpnatc at aiims new delhi sh:- supply, installation, testing and commissioning of wireless water level indicator cum alarm system for all the water tank
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin