Web Analytics Made Easy - StatCounter

Ats Panel Repair Tenders

Get complete information related to latest Ats Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ats Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ats Panel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45712936 Due date: 13 Jul, 202613 Jul, 2026 19.20 Lacs
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor

CTN :45438320 Due date: 06 Jul, 202606 Jul, 2026 45.00 Lacs
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box

Central Government/Public Sector

CTN :45702700 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For auction sale of rolling stock - pl no 98111073 condemned and unserviceable icf bg 8 wheeler coaches no. [1] special repair wgscn 056327 [2] special repair wgscn 054040 [3] special repair rt 900066 [4] special repair gslrd 046712 [5] special repair gs 066410 [6] special repair wgaccn 046111 [7] special repair wgaccn 046139 with all available ferrous-non ferrous electrical fittings with wires, lights, fans, switches, mobile chargers, batteries, battery boxes, wash basins, bio tanks, dust bins, wooden items, ss and aluminium water tanks, porcelain/ss commode/ inlay pans, wall protectors, main doors and lugguage doors, 25kva ac coach under slung inverters and its panels, power cables, pre cooling transformer, wra pumps, power panel, rmpu and control panels, change over rotor switches, rru, bp fp gauge, smoke and heat detection alarm system and there on. rate per number should be quoted. advice note no. [1] 073349-26-08907, dt 18.06.26 [2] 073349-26-08904, dt 18.06.26 [3] 073349-26-08905, dt 18.06.26 [4] 073349-26-08909, dt 18.06.26 [5] 073349-26-08908, dt 18.06.26 [6] 073349-26-08903, dt 18.06.26 [7] 073349-26-08906, dt 18.06.26. approx. weight of the coaches is 206.028 mts. on as is where is condition. note: [1] cutting permitted to cut the coach into two pieces [center cut]. [2] crane loading permitted. [3] coach in grounded condition without bogie complete set(location: mettu line nearby ipf colony office goc)

CTN :45690396 Due date: 02 Jul, 202602 Jul, 2026 25.59 Lacs
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &

CTN :45344756 Due date: 22 Jun, 202622 Jun, 2026 30.00 Lacs
Tender For corrigendum : : work of maintenance of various equipment’s at 33 kv control panel/ vcb/line isolator including retro fitting of damaged protection relay and maintenance & repair work of 11 kv vcb along with erathing of power t/f & control room & inreacting capcity of power t/f (at 33/11 kv quila s/s) etc. in different 33/11 kv s/s under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2025-2026).

State Government

CTN :45442297 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For corrigendum : tender for complete repair of different electronics modules or dc power supply cards of governor control panel and avr cards at 3x 1.5 mw thirot power house under the resident engineer, larji power house division hpsebl, thalout - tender for complete repair of different electronics modules/dc power supply cards of governor control panel and avr cards at 3x 1.5 mw thirot power house under the resident engineer, larji power house division hpsebl, thalout.’

Central Government/Public Sector

CTN :45577862 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; design, supply & commissioning of plc-based ac control panel along with power & control cable laying & termination for horn 3 hydraulic press at sru ..

State Government

CTN :45315676 Due date: 29 Jun, 202629 Jun, 2026 13.77 Crore
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment

State Government

CTN :45384766 Due date: 15 Jun, 202615 Jun, 2026 6.58 Lacs
Tender For pre-monsoon repair and maintenance of hydraulic power pack system and electrical control panel system and oiling greasing of 5 no. radial gates size 7.5 m x 5.5 m of bagharru medium project, district vidisha (m.p.)

Central Government/Public Sector

CTN :45374834 Due date: 12 Jun, 202612 Jun, 2026 9.95 Lacs
Tender For repair/ maint of lt over head line, lt pole and busbar with connected accessories at hq igar (e) srikona. - schedule a part - i, supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 25 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 35 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 50 sqmm 3.5 core, complete including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 70 sqmm 3.5 core including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., m&l for preparation of surfaces of pole for painting of steel tubular pole,vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by engineer-in-charge on poles and numbering with writing letters or figures(block) complete all as directed., s&f street light control panel confirming to ip 66 protection mounted on wall/pole/pcc foundation with suitable ms clamps & nut bolts etc installation and testing including 01 no mcb tpn 63 amp (incomer),01 no contactor 63 amp 3 pole , 230v 3p module astronomical time switch , bakelite fuse fitting with 2 a hrc fuse,indicaion lamp,mounting lugs,panel lock,hinged door,auto manual selector switch 6 amp, detachable mounting din channel,supply monitoring device complete all as specified and directed, supply and fix high efficient ip-66 led street light 70 watt with high power leds, having aluminium pressure die cost housing and pc cover in the front and lens for light distribitioon and saving of energy efficient including service bracket and making of fixing arrengement all as direct by engr -in-charge., labour only for stringing loose lt line alumunium conductors as per direction of engr- in -charge, supply and fixing lt line separator 1100 volts of approved brand and quality, supplying and erection of 100 mm x 65 mm pin insulator complete with g. i. spindle and nuts etc as required .
 Loading, Please wait...

Connect us via What's Up