Web Analytics Made Easy - StatCounter

Audio Alarm Tenders

Get complete information related to latest Audio Alarm Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Audio Alarm Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Audio Alarm Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39920839 Due date: 28 Apr, 202528 Apr, 2025 NA
Tender For bid to ras supply of tower bolts (ferrous metals) as per is 204 (q3) , pressure sensitive adhesive plasticized pvc tapes with nonthermosetting adhesive as per is 7809 (part 3 / section 1) (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , indoor end joint kit for xlpe cable 33 kv of size 300 sqmm , do fuse element 11kv 5 amp , straight through joint for xlpe cable 11 kv of size 240 sqmm , straight through joint for xlpe cable 33 kv of size 300 sqmm , fully automatic star delta starter in sheet enclose 15 hp motor rating ac 3 duty 415v 50hz 3 phase , cable junction box pvc for street light along with alum bus bar and provision of mcb installation , globe for harden light fitting 300mm , heatshrink cable end joint outdoor 11 kv 3 x 150sqmm xlpe cable , xlpe cable joint 11kv of size 120 185 sqmm 3 core ht cable straight through joint termination type , heatshrink outdoor end joint termination joint kit for 3 c x 300 sqmm 33kv xlpe cable , heatshrink cable end join outdoor 11 kv 3x 95sqmm xlpe cable , pvc back for chair varandah not less than 1 point 85 kgs , plywood commercial 8 feet x4 feet x 12 mm , plywood commercial 8 feet x4 feet x 6 mm , plywood commercial 8x4x19 mm , pvc seat for chair varanda with not less than 1 point 85 kgs , paint smoke grey og , looking mirror ladies size 1220x380x5mm thick make prima saintgobin modigurd , hydaulick system in best quality of chair revolving computer , pedestal bottom in best quality of chair revolving computer , twin wheel coasters in best quality of chair revolving computer , high precision telescopic channel made of mild steel 1point 25mm thick of 45kg capacity , supply only on load change over switch front operated switch disconector with extenderd shaft and ip 65 fp 400 amps 36 ka , supply only 3 phase automatic phase sequence corrector of 50 amp load capacity complete make abb , supply only 3 phase automatic phase sequence corrector of 20 amp load capacity complete make abb , xlpe cable alum conductor 3 core 300 sqmm 33 kv , 33 kv e 3 core 300sqmm standard aluminium conductor xlpe armoured cable , solar inverter 100kw , solar inverter 50kw , solar inverter 33kw , solar inverter 20kw , supply hi wall split air condition units in stone walls type split ac inverter model 5 star rating adheriing to specified bee 100 percent copper tubing and of capacity 2 point 0 tr , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed input vairiation between 170v to 250v , refrigerators 310ltr doble door , led kerb stone of size 500mm x 150mm x 200mm made out of 5 foundation rods ensuring complete protection against theft and having a led strip of length 470mm with 22 nos led duly plastic coated of any , gaseous type gravity feed chlorinator of capacity upto 2 kg hrs chemical grade panel board 6mm thick 2 x 4 feet pvc primary filter safety gauge teflon pipe 5 rm ubend secondary filter , new empty chlorine gas cylinder 100kgs capacity along with all accessories , chlorine cylinder emergency safety kit on operating cylinders consist of following accessories cylinder valve hood assembly 01 set cylider valve cap with silver coating valve 01 set , self contained open circuit breathing apparatus with oxygen cylinderfor duration of 30 minutes with audio alarm system light weight fiber glass back plate and two stage pressure reducing , upvc pipes sch 40 with fittings onwalls ceiling or laying in floors of size 25mm complete all as specified and directed by engineer in charge , gaseous type gravity feed chlorinator of capacity upto 2 kg hrs chemical grade panel board 6mm thick 2 feet x 4 feet mounted consist of flow meter , new empty chlorine gas cylinder 100kgs capacity alongwith all accessories , self contained open circuit breathing apparatus with oxygen cylinder for duration of 30 minutes with audio alarm system light weight fiber glass back plate and two stage pressure reducing sys , solar street light 40 watt mad

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
 Loading, Please wait...

Connect us via What's Up