Get complete information related to latest Audio Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Audio Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Audio Cable Tenders.
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on "semi turnkey basis" under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as jointing sleeve binding wire, armour rod etc.
Tender For renovation work of electrical installation in admin block, workshop and washing plant at dtc seemapuri depot. - wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required., wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required., group c, wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required., 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, 2 x 6 sq. mm + 1 x 6 sq. mm earth wire, 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required., 5 x 4 sq. mm, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 32 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 15/16 a switch, 3 pin 5/6 a socket outlet, 6 pin 15/16 a socket outlet, supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required., 3 module (100 mmx75 mm), 6 module (200 mmx75 mm), 8 module (125 mmx125 mm), 12 module (200 mmx150 mm), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 a & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required., wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required., group c, providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required., 150 a, 16 ka,tpmccb, 100 a, 30ka, fpmccb, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator), 12 way, double door, supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copp
Tender For transformer oil filtration , replacement of transformer oil of 400kva, 6.6kv/433v power transformer at stacker reclamier-i,ii,iii,iv, overhaul of 3-phase, 11kv/415v, 2000kva power transformer , overhaul of power transformers at locations of s/r's-i&ii & replacement of failed 433v/415v 3-phase 4-wire power/ lighting distribution/welding /sm transformers of different capacities ,laying different types of power cable in marshaling yard, conveyor galleries, various locations and maintenance of earth pits as and when required in em/chp divison/dr.nttps from 01-04-2026 or from the date of commencement of work to 30-09-2026.
Tender For supply of 3 phase 440 v ac 30kw/40 hp dol starter with 65a tp power contactor having 240v ac coil, 48-65a thermal overload protection and start/stop button, led on/off indication lamp, wall mounted, 96sq.mm digital ammeter with selector switch, mcb, neutral link, 3way power terminals, degree of protection of enclosure ip-42 or higher, 2 nos. earth stud will be given to the panel at the bottom on both sides, cable entry will be from bottom, make-l&t/siemens/schneider/crompton greaves or similar. [ warranty period: 18 months after the date of delivery ] ]
Tender For supply of hf hrc fuse , led pl tube light , led plate , led driver , flp emergency led li , mnx9 contactor , mnx16 contactor , mnx32 contactor , mnx25 contactor , copper earthing wire , on push button , off push button , flameproof jb 4 way , reverse forward jb , flameproof weatherpr , pvc insulation tape , overload relay , smps , no element , nc element , copper ring 95 sq.mm , copper ring 25 sq.mm , 16 sq.mm copper ring , 4 to 6 sq.mm copper rin , 2.5 sq.mm ring type , 2.5 sq.mm pin type c , 4 sq.mm ring type co , 4 sq.mm pin type cop , 2no2nc auxiliary con , frls copper flexible , hdg earth strip , digital earth tester , hot dip galvaanised , nonsparking tool kit , 16a fuse knife type , 20a fuse cylinder ty , 4 pole mcb , rccb , sp mcb , dp mcb , relay , aluminium foil tape , flp push button stat , led flood light , installation of 300w , aluminium cable tags , flp dummy plug , led metal panel ligh , seal wire for bulk l , night torch , helmet with torch
Tender For supply of 48 core unarmoured ofc , plb 32 by 26 mm hdpe pipe wall thickness 3 mm , excavation trenching digging 1.6 meter depth and laying of ofc including splicing at each joint and drops and back filling as per standard , trenching by hdd railway track and roads , right of way row , laying of hdpe pipe including ofc laying and jointing enclosures as per requirement , 48 core fiber joint enclosures , joint chambers or manholes 1 mtr x 1 mtr rcc ring type with cemented base , route marker of 3.5 feet long with engraved marking and 1.5 feet underground in cement base , ofc warning - caution tape , 48 port lc-lc fdf with side mounting and sliding feature and termination of ofc in fdf , tjb metal with wall mounting fitting and accessories , lc- lc duplex patch cords 1 mtrs , lc-lc duplex patch cords 3 mtrs , media converter fibre to rj-45 with power adapter , 15 u l2 rack glass door and locking facility with installation of rack on wall with installed spike buster of 5 socket 16- amp socket and 5 meter power cord , iron bar to be fixed on the wall for l-2 switch rack , cable tray metallic for routing of ofc and cat-vi cable up to l-2 rack , cable manager , patch panel 24 port cat-vi , industrial grid socket , ac spd , chemical earth pit en voltage should be less than 2 volt and earth resistance less than 3 ohms , eearth strip copper from earth pit to l-2 rack , 1 kva ups with online parameter monitoring system , battery bank 12 volt 42 ah
Tender For corrigendum : stage contract for carrying out various electrical maintenance works including sitc, itc of various line materials and distribution substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2026-27 under th - supply, installation, testing and commissioning of 3-phase 25 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 63 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 100 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 200 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 250 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long pcc poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place, providing & fixing of pole earthing as per rec standard as per j-1 (spiral earthing) drawing, supply,fixing of spike earthing rod 20mm 2,5 mtr long with gi strip (25x3)mm, supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint), providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of mild steel of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing & and fixing of 11 kv pin insulators (polymer) with pins ( 5 kn), providing & fixing of 11 kv, g.o ab switch , 3-phase, 200a (09 insulator post type) with arragement for pad locks & operating rod . the operating rod should be g.i pipe (b-class) of 25 mm dia of requisite length., providing & fixing of 11 kv horn, gap fuse 3-phase 100a, providing & fixing of 11kv link set 3-phase, 200 a (station type), sitc of 11kv isolator double break, 3-pole, 630 amps, horizontal mounting type , with earth switch, providing & fixing supply and installation of gapless surge arrestor,9 kv,10 ka, la with (polymer) housing, station type, providing & fixing of lt fuse set of suitable capacity for 63kva,100kva,200kva (as per tender drawing attached), providing & fixing of 11 kv disc insulators (polymer) complete with fitting( 4
Tender For providing of custom bid for services - fabrication of brass gland bush cone with two nos stud nut and washer for providing earth continuity between electrical installation and copper cable of various electrical installations of mkd iii ocm