Get complete information related to latest Audio System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Audio System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Audio System Tenders.
Tender For rate contract for complete repairing and servicing of double acting power cylinder of burner tilt installed in unit no 3 and 4 of sstpp, ph-ii, mppgcl, dongalia.
Tender For work of burner tilt mechanism including replacement of coal nozzle & coal burner tips and air compartments, oil compartments & fuel inlet elbows during aoh of 250 mw unit-3 boiler at paras tps.
Tender For corrigendum : addition / alteration of audio-visual system at vigyan bhawan, new delhi (sh supply, installation, testing and commissioning of audiosystem for hall no. 6 at vb)
Tender For establishment of smart/hybrid classroom including supply, installation,testing and commissioning on turnkey basis -0 75" inch interactive flat panel display with inbuilt android, ops support and wall mount , digital teaching podium with inbuilt pc desktop, touch panel control and integration ports , 5 kva online ups with battery backup for complete smart class system , ptz camera vc grade with mounting accessories (for hybride teaching and vc) , full hd visualizer (doit compliant) for content sharing , dsp based hybrid classroom audiosystem including mixer, amplifier and processing , wallmount speakers (classroom coverage type) , wireless microphone system including handheld + lapel mic set , student chair with writing pad (powder coated fram, cushioned seat) , table (teacher) front teaching and control use , split air conditioner 2 ton (for conference load smart classroom) , high back chair (teacher) , sitc including smart led lighting, lan networking, electrical points, painting, spc wooden flooring, blackout curtains, teaching platform laminate finishing, camera mounting, installation hardware and connectors complete job
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s
Tender For corrigendum : smart class equipment with digital contents software - interactive panel: 86 inches with ops/mini pc (qty. 3) , mini pc configuration(qty. 3) , camera for lecturer and student:lecturer camera: (qty. 3) , ptz camera , podium with central control:(qty. 3) , audiosystem with mike and speaker:audiosystem. οεν. 5) , mic, speaker , camera , ups ,
Tender For corrigendum : electronic audiosystem and smart digital board system under the scheme modification and upgradation of rooms for panchayat office conference hall. activity id- 127537537
Tender For corrigendum : comprehensive preventive breakdown and general maintenance of digital audiosystem along with associated equipments installed in lecture hall at csir vigyan kendra lodhi road new delhi