Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For supply of proc of 48 line exchange - ip pabx system with configuration and installation commissioning , digital key phone , operator console with 32 dss keys , 100 pair mdf idf box with original krone plate module , ipm for power protection on extensions , additional cpu card , additional psu card , e1 isdn cept card with optical termination single port each , e1 isdn pri cept card one port each , voip gateway card for 16 channel , gsm card for 4 port gsm sim 4g volte support , radio interface card with assy , ip based emergency hooter gateway , line extension card for 16 ports , digital line card for 8 ports , analog junction card 8 ports , analog cli with speaker phone , digital grounding device single phase , fcbc
Tender For supply of proc of 128 lines exchange d d - ip pabx system with configuration and installation commissioning , digital key phone , operator console with 32 dss keys , 200 pair mdf idf box with original krone plate module , ipm for power protection on extensions , hot standby card for cpu , hot standby card for psu , e1 isdn pri cept card with optical termination single port each , e1 isdn pri cept card one port each , voip gateway card for 32 channel , gsm card for 8 port gsm sim 4g volte support , ip based emergency hooter gateway , line extension card for 32 ports , digital line card for 16 ports , analog junction card 16 ports , digital grounding device single phase , fcbc
Tender For supply of multi detector , 24v dc manual call point , fire alarm electronic hooter cum strobe , metal base back box for all detectors , 12 mm gland , frls armoured pvc insulated copper conductor cable
Tender For repair and overhauling service - kg5h 230 kpcl; kg5h 230 kpcl; yes; buyer premises, service provider premises-detailed defects: (a) fuel level indicator qty-01 u/s, needs to be replaced. (b) 1st stage (3.7 kg/cm2) qty-02 and 5th stage (264 kg/cm2) safety valve qty02 u/s, needs to be replaced. (c) hooter qty-01 and fire extinguisher qty-02 u/s. (d) charging alternator qty-01 and starter motor qty-01 u/s, needs to be repaired. compressor dip stick qty-01 broken, needs to be replaced. (e) pressure gauges (0-7 kg/cm , 0-21 kg/cm , 0-70 kg/cm , 0-16 kg/cm , 0-400 kg/cm ,0-600 kg/cm ,0-150 kg/cm ,0-150 kg/cm ,0-15 kg/cm ,0-15 kg/cm ) total qty-10 u/s, needs to be replaced. (f) drainage pipelines of dampner qty-06 and purge bottles qty-06 blocked, needs to be replaced. (g) pneumatic door struts qty-20 u/s and door hinges qty-12 broken, needs to be replaced. (h) delivery valve (0-400 kg/cm2) qty-04 and vent valve (0-400 kg/cm2) qty-04 u/s, needs to be replaced. engine solenoid 24v qty-02 and rmp meter qty-01 u/s, needs to be replaced. mechanical jack qty-04 u/s, needs to be repaired. (k) dew point meter qty-01 u/s to be repaired and calibrated. door lock qty-06 u/s, needs to be replaced. (1) charging adopter damaged qty-06 u/s, needs to be replaced. (m) search light qty-04 and panel light qty-06 u/s, needs to be replaced. (n) pre filter differential gauge qty-01 (range 0-1.5 kg/cm2) u/s, needs to be replaced (o) charging alternator, mechanical lubricator and radiator fan belt (qty-03) teared off, needs to be replaced. (p) silica gel of both dryer units saturated and needs to be replaced. pre filter, oil filter and after filter element (total qty-03) to be replaced. (q) air filter, fuel and oil filter element (total qty-03) to be changed..
Tender For bid to ras bid to ras corrigendum : supply of ce010280019: fire alarm panel for fda in lhs, qty: 1 no , st050070109, addressable multi criterial detectors intelligent analog capable of giving exact locati , st050070108, addressable smoke detectors intelligent analog capable of giving exact location of , st050070107, addressable heat detectors intelligent analog capable of giving exact location of fire, , st050070106, addressable manual call points-indoor type, qty: 102 nos , st050070105, ir flame detector with addressable module, qty: 18 nos , st050070104, addressable hooter, qty: 40 nos , st050070103, interface unit (monitoring module) , qty: 96 nos , st050070102, interface unit (control output module) , qty: 150 nos , st050070117, response indicators, qty: 12 nos , st050070100, sounder strobe for fire protection panel, qty: 36 nos , st050070111, emergency exit & warming sign, qty: 15 nos , st050070112, junction boxes, qty: 72 nos , material code: st050070113, linear heat sensing cables, qty: 5000 metres , st050070046, dvcp(deluge valve control panel) box for fdaamvwss, qty: 24 nos , st060300228, pressure switch: ds-802/m 0.5-15 bar nr: 658015, hagglunds pn: 577 8810-012, rexroth pn: r9 , st060290229, pressure gauge 0-16 bar, glycerine filled, 1/2 inch npt m, qty: 80 nos , st050070114, solenoid valve, qty: 40 nos , st050070115, 24v dc power supply, qty: 30 nos , st050070116, fire alarm repeater panel, qty: 1 no , sc440020046, 1100v grade 3 core 1.5 sq. mm frls cable, qty: 12000 metres , sc440020103, 1100v grade 2 core 1.5 sq. mm frls cable qty: 7000 metres