Web Analytics Made Easy - StatCounter

Auditorium Repair Tenders

Get complete information related to latest Auditorium Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auditorium Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auditorium Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45734008 Due date: 20 Jul, 202620 Jul, 2026 49.00 Lacs
Tender For periodical services, smart painting and repair to rcc chajjas, facia, parapet, columns, beam and connected items to intrnal/ extrnal surfaces of building in c2a and c2b ara and fafa under ge (east) mathura

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

CTN :45711090 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For spare parts of scania - connector 1/4" part no 140523, oil collector part no 257319, hand brake valve part no 249914, switch, foot dipper part no 159656, stop light switch part no 158717, t-connector part no 229020, air dryer part no 258985, charging valve part no 215619, elbow connector part no 146235, elbow connector part no 229704, pressure regul. valve part no 5360042991(230787), safety valve part no 293542, valve seat part no 229358, repair kit part no 263664, repair kit part no 263667, bumper part no 249727, stop part no 217280, contact holder part no 235650, sliding contact part no 130770, cap lower part part no 1102372, cap upper part part no 1102371, oil container part no 197804, hydraulic oil pump part no 259310, relay part no 371912, comp circuit part no 259240, relay part no 173554, block terminal part no 353489, socket part no 255080, starting socket part no 231631, battery main switch part no 197811, gear selector (gear box) part no 6695000734(393779), gear selector (transfer box) part no 5895022571(393777), tandom driving cable part no 1149732, bulb 2w/24v part no 258491, panel, switches part no 248821, panel, control lamps part no 248820, map reading lamp part no 218412, control lamp oil pressure part no 239170, control lamp full beam part no 239173, light filter part no 246680, control lamp (direct indicator i) part no 239174, control lamp (gear box oil temp) part no 255073, control lamp coolant temp part no 246856, control lamp (reversing light) part no 249300, plate, blackout lighting part no 391567, techometer part no 258660, comb instrument part no 268353, oil pressure gauge part no 259794, water temp gauge part no 249108, fuel gauge part no 249109

CTN :45717001 Due date: 13 Jul, 202613 Jul, 2026 5.61 Lacs
Tender For tender for satisfactory trial. , carry out strengthening work using the channels and angles provided by src and irc and conduct a satisfactory trial. , to fabricate the weak sloppy plates of the donali suit fitted on milo from the given ms plate as per the drawing and give a satisfactory trial. , removing the worn out trpf cover fitted on the mill and making and fitting a new cover using the plate given as per the drawing sample and giving a satisfactory trial. , to carry out the work of tipping the teeth of mill rollers and conduct a satisfactory trial. , to carry out the work of chevron cutting as per requirement on mill rollers and give satisfactory trials. , work involving the errectation of broken teeth on the mill s pressure chute repair of worn out teeth via hard facing and conducting a satisfactory trial run , dismantling the old pressure chute errected on the mill completely replacing the corroded section repairing and welding the damaged parts of the ss plate reassembling the unit fitting it onto the mill , fabricate the juice tank for the mill house using the provided 6 8 mm plate and conduct a satisfactory trial run , removing the bottom of the supply juice tank errecting a 12 mm plate in its place and conducting a satisfactory trial. , manufacturing the bed for the s.r.c. and i.r.c. motor gear and conducting a satisfactory trial. , remove the worn out trpf headstock side plate errect a 6mm plate in its place and conduct a satisfactory trial. , fabricating teeth for the hydraulic grab replacing old or damaged teeth with new ones and conducting a satisfactory trial run. , a dismantling old columns beam channels etc. b manufacturing and installing new columns beam channels etc. , removing the old corroded platform and replacing it with a new one. , installing 16 inch 18 inch manholes with blinds , constructing a bed for the pump fitting the pump and motor and conducting a trial run of up to 20 hp. , dismantling fabricating and erecting weak corroded pipe lines up to 12 inch and providing satisfactory leak proof trials. , dismantling fabricating and erecting weak corroded tees up to 12 inch and providing satisfactory leak proof trials. , dismantling fabricating and erecting weak corroded nipples up to 12 inch and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated cross member up to 12 inch and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated band up to 12 inch and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated flange up to 12 inch and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak sloping reducer up to 12 inch and providing a satisfactory leak proof trial.

CTN :45716965 Due date: 13 Jul, 202613 Jul, 2026 3.27 Lacs
Tender For tender for remove the worn out runners from the main bagasse carrier bagasse elevator and return bagasse carrier errect 8x65 10x50 mm flat iron bars in their place clean the welded areas using a grinder , cut and remove the worn out bottom plates of the main bagasse carrier bagasse elevator and return bagasse carrier errect new 6 8 10 mm , cut and remove the worn out side plates of the main bagasse carrier bagasse elevator and return bagasse carrier errect 6 8 10 mm plates satisfactory trial run , cut out and remove the damaged and weak sections of the main bagasse carrier fabricate and errect a new assembly including the gear shaft system using the supplied plate , cut out and remove the weak and corroded sections of the bagasse feeding chutes errected boilers fabricate and replacements using the provided plates and repair the associated shafts and gears , the casings of the boiler id and fd fans have become severely weakened and damaged the task involves cutting away and removing the weakened sections fabricating , cut and remove the deteriorated side bottom and top plates surrounding the air heater of boiler no. 3 fabricate and errect new plates using the specified 6 8 mm plate in their original positions , fully strengthen the air heater plates and conduct a satisfactory trial. , dismantling the old air heater tubes of boiler no. 01 size 63.5 mm od x 2.64 mm thickness fabricating and errecting new tubes in accordance with the drawing , dismantling the old air heater tubes of boiler no. 02 size 63.5 mm od x 2.64 mm thickness fabricating and errecting new tubes in accordance with the drawing , dismantling the old air heater tubes of boiler no. 03 size 63.5 mm od x 2.64 mm thickness fabricating and errecting new tubes in accordance with the drawing , a. dismantling old columns beam channels etc. b. manufacturing and installing new columns beam channels , installing 16 inch 18 inch manholes with blinds , constructing a bed for the pump fitting the pump and motor and conducting a trial run of up to twenty hp , dismantling fabricating and erecting weak corroded pipe lines up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting weak corroded tees up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting weak corroded nipples up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated cross member up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated band up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated flange up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak sloping reducer up to 12 and providing a satisfactory leak proof trial. , removing the old corroded platform and replacing it with a new one

CTN :45690396 Due date: 02 Jul, 202602 Jul, 2026 25.59 Lacs
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &

Central Government/Public Sector

CTN :45664417 Due date: 21 Jul, 202621 Jul, 2026 55.00 Lacs
Tender For repair and restoration of fundamental members like column beam slab and connected items including scheduled internal and external finishes to building of dbm agm sbm htl ltl utl waiting room workshop offices and other otm accn etc in nad explosive area a

Central Government/Public Sector

CTN :45506167 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For corrigendum : providing of custom bid for services - repair of cooler chute, fabrication & erection of z-beam, canopy

Central Government/Public Sector

CTN :45637781 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For auction sale of depot ferrous scrap - cast steel scrap consisting of yoke, knuckle, coupler body, buffer plunger, equalizer beam, centre block, repair kit, pinion, gear cp top, cp bottam, narrow & wide jaw adaptor, center pivot, axle box, brake discs, lock lift assembly, cbc housing with and without rubber, block schaku coupler item, brake beam, piece of bogie frame, bhrr adopter, nut, bolt and other miscellaneous cs/ci scrap unservicible for railway use. mode of delivery by actual weight fdp-40 days. material should be loaded with one end from lot as per description.

Central Government And Public Sector

CTN :45624441 Due date: 07 Jul, 202607 Jul, 2026 29.62 Lacs
Tender For supply of material under minor civil and electric work (conservation of (conservation of ancient monument) to repair of ruined part and adjoining area of seventh gate inside kalinjar fort, banda. - supply of materials, brick ballast 25 mm gauge (1st class bricks), unslaked lime (katni), surkhi powder 1st class, coarse sand meadium gauge (betwa), gur/sheera in semi liquid form, dry gum in crystel form not less than 3 mm, dry bel fruit giri, flagstone 60x60 cm and above of thickenss 50 mm with permissible variation in 5% in thickness, flagstone 60x60 cm and above of thickenss 75 mm with permissible ivariation in 5% in thickness, r.r. stone boulder (10-30 kg), san (raw jute), sand sotne beam (3.00x0.30x0.30m)
 Loading, Please wait...

Connect us via What's Up