Tender For corrigendum : supply of traction transformer for hs-spic with required number of secondary traction windings along with protection equipment, safety chain arrangement and ht cablewith protection shield including termination crimping lugs, cable markers with heat shrinkable sleeves for power and control cables, mating connectors, equipment mounting and earthing hardware and accessories including auxiliary machines such as oil pump, oil cooling blowers as per clause 4.3 of rdso specification no. rdso/pe/spec/emu/0196-2019 (rev.0) along with mounting hardware (one set per hs-spic)., as per drawing: as per clause 4.3 of rdso specification no. rdso/pe/spec/emu/0196-2019 (rev.0), packing instruction: suitably covered with biodegradable transparent polythene and packed in wooden box.the material used for product packaging shall be eco-friendly .each packing shall be stenciled/labeled handle with care, consignee name, order no,pl's no , description ofitem, batch no, drg/spec no, qty,firm's name, &date of despatch etc. note- 1) firms have option to provide qr code. for linkage of po, the cardboard box shall carry a qr code having details as listed below: a)nameof the manufacturer b)purchaseorder number c)purchaseorder date d)uniqueserial number (or lot number for bulk items) of the manufacturer or e)dateofmanufacture f)deliverychallan no. g)deliverychallan date 2.the qr code shall be as per iso/iec 18004 model2 and the data shall be available as xml using the tags detailed above. [ warranty period: 36 months after the date of delivery ]
Tender For supply of 1) smart glass control panel with electronic converter equivalent to make aepl with following specification: input: 135-255 vac, 50hz single phase output: 110vac +-5% regulation, 50hz single phase, power:400va/280 watts (distributed through two transformer arrangement) each to power 5 glasses totalling 10 glasses :layout and design : to suit the existing panel input and output cabling - one to one connection. physical dimensions of panel : 665 mmx465mm x 215 mm (l*w*h)-01 nos. 2) towards providing external switch suitable for vistadome panel suitably pre-wired within the above panel-02nos. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 100va, 750/110 v ac, single phase, type-iv dry type and air cooled control transformer as per rdso spec: rdso/pe/spec/ac 0203-2020 (rev.0) for non ac lhb coaches. one set consists of 03 items: (1) 100va control transformer - 01 no. per set, (2) 2a, 500v, 120 ka (gg) fuse of size 10x38 along with fuse holder - 02 nos. per set and (3) f2a, 1.2 kv fuse along with fuse holder - 02 nos. per set. firm should submit test report & certificate of authorization from oem. [ warranty period: 30 months after the date of delivery ]
Tender For supply of control transformer of 125va capacity , bridge rectifier package 10 amps 400v , transistor 2n 3373 , pcb assembly for battery charger of hand signal lamps , bunch of 45 leds red colour , 1000 mfd 40 63 volts capacitor , metal diode 16 amps 400 piv , cooling fan suitable for battery charger , fuse holder for 10a capacity glass fuse , push on switch type no 0901 , bunch of 45 leds yellow colour , glass fuse rated for 10 amps
Tender For auction sale of iron/steel scrap as per lot description,brass, al scrap as per lot annexure,various tyres as per lot annexure,transformer oil old and used etc,old and used copper and aluminium control cables etc
Tender For bid to ras tender for supply of control transformer 1 ph3kva 50hz pri 0slash230slash240slash250v sec 0slash10slash17slash30v as per bhel spec no ceeslash22016 revhyphen00 itemhyphen1 , control transformer 2kva 415slash100v 3hyphenph yy0 50hyphen300hz as per bhel spec no ceeslash22001 revhyphen01 itemhyphen1 , control transformer 30va 100slash110v 3hyphenph yy0 50hyphen300hz as per bhel spec no ceeslash22001 revhyphen01 itemhyphen3 , control transformer 500va 100slash0hyphen162hyphen170v(rated at 170v) 3hyphenph 50hyphen300hz yy0as per bhel spec no ceeslash22001 revhyphen01 itemhyphen6 , control transformer 2kva 246slash220v 3hyphenph 50hyphen300 hz yy0 as per bhel spec no ceeslash22001 revhyphen01 itemhyphen7 , control transformer 15va ct ratio 0hyphen5hyphen1slash1a 1hyphenph 50hz accuracy class 02 for metering as per bhel spec no ceeslash22001 revhyphen01 itemhyphen8
Tender For supply and installation of 3 phase hog sequence testing kit with 60kva transformer for inspection of lhb ac and non-ac coaches with following specifications. 1) hog sequence testing kit shallbe suitable for input supply of 3 phase, 415v with neutral, 125a four poles mccb shall be provided forinput supply side protection along with suitable rated supply chord (pvc) of length 5 meters. 2) hogsequencetesting kit shall be having output supply provision of 3 phase with neutral, 750v ac with ivcoupler socket. 3) uic jumper coupler shall be having 16 pin male connector to suit conventional powercar socket, the cable length shall be 3 meters. 4) hog sequence testing kit shall be having auto overvoltage shut down facility. 5) hog sequence testing kit shall be having the output capacity of 60kva forpower side and 72 to 110v dc for control side. 6) hog sequence testing kit shall have in built surgeprotection. 7) hog sequence testing kit shall be having 4 polemccb protection at 750v side, withcurrent rating 125a. 750v ac grade not available 690v mccb shall be used. 8) hog sequence testing kitshall be having independent on/off and rest provision for each output. 9) hog sequence testing kitshall be having proper earthing protection. 10) the power circuit and control circuit arrangement shall beloco part of drawing entered in annexure 1. 11) hog sequence testing kit shall be supplied with fourwheels heavy duty trolley two revolving and two fixed one. 12) hog sequence testing kit shall bepowder coated paint of aqua green colour. 13) hog sequence testing kit shall be supplied along withuser manual. 14) demonstration shall be arranged free ofcost at your side. 15) hog sequence testingkit shall be suitably designed at both sides. 16) hog sequence testing kit shall be labeled withnecessary danger/safety precaution instructions wherever necessary. pre approval of drawing & bom to be taken from consignee before supply of item. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply and installation of 3 phase hog sequence testing kit with 60kva transformer for inspection of lhb ac and non-ac coaches with following specifications. 1) hog sequence testing kit shallbe suitable for input supply of 3 phase, 415v with neutral, 125a four poles mccb shall be provided forinput supply side protection along with suitable rated supply chord (pvc) of length 5 meters. 2) hogsequencetesting kit shall be having output supply provision of 3 phase with neutral, 750v ac with ivcoupler socket. 3) uic jumper coupler shall be having 16 pin male connector to suit conventional powercar socket, the cable length shall be 3 meters. 4) hog sequence testing kit shall be having auto overvoltage shut down facility. 5) hog sequence testing kit shall be having the output capacity of 60kva forpower side and 72 to 110v dc for control side. 6) hog sequence testing kit shall have in built surgeprotection. 7) hog sequence testing kit shall be having 4 polemccb protection at 750v side, withcurrent rating 125a. 750v ac grade not available 690v mccb shall be used. 8) hog sequence testing kitshall be having independent on/off and rest provision for each output. 9) hog sequence testing kitshall be having proper earthing protection. 10) the power circuit and control circuit arrangement shall beloco part of drawing entered in annexure 1. 11) hog sequence testing kit shall be supplied with fourwheels heavy duty trolley two revolving and two fixed one. 12) hog sequence testing kit shall bepowder coated paint of aqua green colour. 13) hog sequence testing kit shall be supplied along withuser manual. 14) demonstration shall be arranged free ofcost at your side. 15) hog sequence testingkit shall be suitably designed at both sides. 16) hog sequence testing kit shall be labeled withnecessary danger/safety precaution instructions wherever necessary. pre approval of drawing & bom to be taken from consignee before supply of item. [ warranty period: 30 months after the date of delivery ]
Tender For supply of round the clock maint of bchp wt to conv 8 , round the clock maint of bchp main route , round the clock elect. maint of a chp , shifting of 5 ton weights to wb , laying power cable up to 70 mm2 , laying power cable up to 70 to 400 mm2 , dismantling power cable up to 70mm2 , dismantling power cable upto 70 to 400mm2 , laying of different size of power cable , dismantling of difft of control cable , digging of existing cable trench , degging trench for relaying new cable , straight through jointing of lt cable , end termination of power cable , straight through jointing of ht cable , bend termination of power cable head , patrolling of ht cable upto 70mm2 , patrolling of lt cable up to 70mm2 , patrolling of ht cable upto 70 to 400mm2 , patrolling of control cable up 4mm2 , repairing fabrication of lighting panel , rewinding of ceiling fan , replacement of bearing of celing fan , provide bearing in place of bush , replacement of condenser of celing fan , replacement of shaft of ceiling fan. , complete oh of celing fan , cable trench of fuel handling area. , cable trench jt no.1 and crusher house , cable trench jt no.1 and jt no.2. , chp transformer trench to ahd unit 12 , cable trench from crusher house to wts , cleaning of mcc panel wt,sr fhd etc , cleaning of sm,md,coolin g pump,wb area , cleaning of control power panel fhd , cleaning of ldb in fuel oil in btps. , cleaning of control room,wb area a chp , cable rack and trays of fuel oil pump house , cable rack trays riser of crusher house. , cable rack trays riser of tower no.1 , cable rack between j.t. no.1 and conv. 16 , cable racks from jt no 1 and conv. 17. , cable rack trays of old stacker. , cable rack trays of new stacker. , cable rack trays from j.t. no.1 and j.t. 2 , cable rack trays of riser of j.t. no.2 , cable rack minus 4m gallery chp room , cable rack berween t.t. no.2 and t.t.no.3 , cable rack trays riser of tippler area. , cable rack trays riser of wagon tippler. , cable rack trays of conv. k10 , cable rack trays of conv. k16. , cleaning of floor gallery minus 4m chp , ceaning of panel in fuel oil , cleaning of sg room, trench a chp , cleaning of a chp cable trench sg area , cable trenches from c.h. to wts chp , cable trenches from jt no.1 to c.h. , cable trenches from jt no.1 to jt 2 , cable trenches from wt a chp to id fan , cable trays from wt a chp to id fan , o.h. and maint. of 5 and 10t hoists bchp , o.h. and maint. of 20 and 5t hoists and eot achp