Tender For corrigendum : se 2314: supply of cooling fan motors with accessories for 250 mva 13.8/400kv generator transformer & 20 mva 13.8/11kv station transformer for emd rbph at gsecl, sshep, kevadia colony.
Tender For replacement of 1x8 mva, 66/11kv power transformer-1 and 1x12.5mva, 66/11kv power transformer-2 by 2x20 mva 66/11kv power transformers at 66/11 kv substation, madanayakanahalli in chitradurga taluk and chitradurga district including supply of equipments /materials, dismantling and erection (including civil works), under partial turnkey basis, on percentage tender basis (excluding the supply of major materials such as power transformer and nifs, which will be supplied by kptcl, testing and commissioning, done by kptcl rt staff).
Tender For replacement of 2x12.5 mva, 66/11kv power transformer by 2x20mva 66/11kv power transformer at 66/11kv sub-station kadajji, davanagere taluk, davanagere operation division, kptcl, davanagere district including supply of equipments / materials, dismantling and erection (including civil works) under partial turnkey basis, on percentage tender basis.
Tender For corrigendum : establishing 2x12.5 mva, 66/33kv and 1x12.5 mva, 66/11kv sub-station at katakeri along with construction of proposed 66kv lilo line from the existing 66kv madikeri-virajapete sc line on dc towers to proposed 66/11kv sub-station at katakeri for a distance of 4.765km in madikeri taluk, kodagu district on partial turnkey basis including supply of all materials/equipments (excluding supply of 1x12.5mva, 66/11kv power transformer and 11kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning.
Tender For corrigendum : for dismantling and shifting of old 20 mva 132/33 kv ngef make x-mer and other associated work of 132 kv and 33 kv bay of proposed 50 mva transformer bay at 220 kv s/s nepanagar under testing div. khandwa
Tender For corrigendum : for replacement of old double zebra conductor to new double zebra conductor of 33kv incoming side of 40 mva & 63 mva transformer and replacement of old single panther conductor to new single zebra conductor of 132kv side of 40 mva & 63 mva transformer and dismantling and erection of 220kv bus section isolator with associated works at 220kv s/s barwaha under t. dn. barwaha.
Tender For corrigendum : supply of repair and rewinding e e - opening of transformer cover draining oil de-tanking core- coil assembly assessment and estimation for repair and replacement of parts providing locking arrangement of all valves and plugs , loading and unloading of transformer at side cph and firms work premises hiring , hv leg coil with insulation varnish and baking of coil assembling vacuum , lv leg coil with insulation varnish and baking of coil assembling vacuum impregnation new ec grade copper with insulation , set of gaskets rubberized cork neoprene material and size is needed for hv and lv , breather dehydrator silica gel type with fresh silica gel 01 kg , fresh transformer oil of standard quality as per the isi mark for main tank and oltc , double float buchholz relay including all accessories , air release valve including all accessories if required , magnetic oil gauge including all accessories if required , radiator valve including all accessories if required , reassembling of 3 15 mva transformer dyn 11 star delta connected with proper size of copper strip , replacement change of complete gaskets rubberized cork neoprene material , the oltc was completely repaired with the replacement , painting charges of transformer tank having hot oil resistant paint inside and synthetic enamel paint on transformer after cleaning of tank and complete painting outside etc as reqd. , less the cost of old and burned transformer oil plus old transformer oil of oltc , less the cost of old and dismantling insulated copper