Tender For corrigendum : tender for supply of system description general requirements including cyber security technical requirements full hd fixed box type ip colour camera with varifocal lens and housing & mount 4k uhd fixed box type ip colour camera (type a/type b) with varifocal lens and housing & mount full hd bullet type ip colour camera 4k uhd bullet type ip colour camera (type a/type b) full hd fixed dome type ip colour camera full hd ptz (pan, tilt, zoom) ip colour camera digital keyboard large format display monitor server/workstation hardware network video recorder (nvr) pc workstation external storage device core switch (1). aggregation switch (ii). layer 2 switch (24 port) a. poe b. non-poe (iii) field switch a. b port b. 4 port wireless transmitter/receiver unit copper to fiber media convertor various types of cables software requirement video management software graphical user interface client software video recording software artificial intelligence (al) enabled video analytics software remote viewing on web and mobile app functional requirement of command control centre (ccc) software face recognition software software license test requirements test procedure quality assurance making and packing information to be supplied by the purchaser training documentation schematic diagram- 1: schematic diagram of ip based video surveillance system at stations schematic diagram 2: schematic diagram for video surveillance system for cluster of stations schematic diagram- 3: schematic diagram for cloud based architecture of video surveillance system for cluster of stations
Tender For supply of sdr tac version 1a with installation kit , access token blue admin tac , access token yellow user tac , headset assy , handset assy , gps antenna with cable assy , maintenance tools , mfg nc , cfg nc , wld , hld , rf cable assy lmr600 4 x 150 meters , remote control unit sdr tac , network time server with accessories and installation material , vhf and uhf coaxial dipole , l band antenna , sdr manpack including battery and charger , access token blue admin mp , access token yellow user mp , child fill gun with cable assembly , analog handset , attenuators , test jig for dpm card assy , user interface device , gps antenna l1 and l5 , manpack blade antenna , data cable assy , power supply cable , sdr handheld including battery and charger , debug card , gps antenna , rf antenna , data cable
Tender For bid to ras supply of 6s battery charger for modified drone , battery charger for 3s to 6s for modified drone , battery charger for dji mavic plus air 3 drone , multipurpose tool kit taparia consisting of 24 items , battery checker , digital multimeter hand held , digital microscope with 9 inch lcd screen 1000 x magnification , dc regulated power supply 0 to 30 volt 10 amp , dc regulated power supply 0 to 60 volt 20 amp , tempraure controled soldering station , three in one yihua 992da plus soldering iron smoke obserb function hot air gun smd soldering rework station , surface mount device work station , bench top multimeter , air conditioner split one x half ton , voltage stabilizer 4kva copper , remote control for dji drone model rc 02 , remote control for dji drone model rc 01
Tender For supply and installation or urs at various areas of zone south, jodhpur - providing & laying xlpe insulated & p.v.c. sheathed armoured aluminium cable confirming to is :7098 p - i of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray(with cable tie) including testing commissioning etc. as required of following size.10.0 sq. mm x 4 core, supply & installation of unified regulation system (urs) for existing street light that meets the following specification.the system must feature a 240mhz dual core processor with gsm/gprs communication capabilities and support for ota firmware updates.it should come with an internal class 1.0 energy metering system that can provide real time data of crucial electric load parameters along with fault and theft alerts.the urs must include remote load scheduling and control functionalities with a feedback time of less than seconds.the enclosure confirms to ip55 standards,and be fire retardant,weatherproof,and rustproof. the system should use a lightweight protocol for secure ,real-time communication and include cloud based software for comprehensive device management and remote control. it should be able to control single phase 5.5kw and 3 phase street light load upto 8.5kw and should come with 2pole/4pole mcb upto 25a/40a at output for short circuit protection .having a 2-year warranty urs will be installed at site as per direction of engineering incharge. (size 570*520*190mm)
Tender For supply of fully automatic double door steam sterilizer eight stu five hundred seventy five to six hundred lts including all required civil electrical and plumbing work , free standing ultrasonic washer with irrigation including all required civil electrical and plumbing work , fully automatic cart and trolley washing system with accessories including all required civil electrical and plumbing work , automatic sealing device for flexible endoscopes including all required civil and electrical work , cssd management tracking traceability and remote supervision software system , wash station with two sinks including all required civil electrical and plumbing work , magnifying lamp , pass box , control and packing table with two shelves , working table , fresh linen storage rack , free standing basket rack , closed transport trolley , washer and drying gun , documentation labeler , ro system with water tank and pressure pump including all required civil electrical and plumbing work , office table , staff chair , visitors chair , storage cupboard , waste bin pedal operated ss , computer system , change locker four compartments , turnkey work complete with all accessories as per technical specifications which include all civil electrical plumbing works or any other work as required , comprehensive annual maintenance contract threeyear for sl no one to twenty three , comprehensive annual maintenance contract four year sl no one to twenty three , comprehensive annual maintenance contract fiveyear sl no one to twenty three , comprehensive annual maintenance contract six year sl no one to twenty three , comprehensive annual maintenance contract seven year sl no one to twenty three , comprehensive annual maintenance contract eight year sl no one to twenty three ) /bid number : gem/2026/b/7549954 * /dated: 16-05-2026 & & / bid document 1 / 26
Tender For supply of wireless video boroscope %u2013probe/lens diameter %u2013 6mm, 12 mm,field of view ofcamera %u2013 60 degree or more, remote control- for rotation of.... wireless video boroscope %u2013probe/lens diameter %u2013 6mm, 12 mm,field of view of camera %u2013 60 degree or more, remote control- for rotation of camera, length of probe- 1 meter or more, storage- 2 gb or more, display unit- at least 300000 pixels, device can be connected on separate screen to view video., ingress protection %u2013ip-55 or above, battery %u2013 backup for more than 3 hrs., data transfer-data can be transferred to computer using usb lead/drive.-03 nos. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi