Web Analytics Made Easy - StatCounter

Automatic Control Device Tenders

Get complete information related to latest Automatic Control Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Automatic Control Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Automatic Control Device Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45279869 Due date: 11 Jun, 202611 Jun, 2026 2.90 Lacs
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission

CTN :45279655 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For corrigendum : supply of excavation soft and loose soil not exceeding 1 point 5 metre deep and wide , returning filling in soilsspreading leveling watering and well ramming , removal of surplus soils not exceeding 50 mtr distance , m and l for sand filling with clean dry fine sand unwashed , s and l un reinforced pre cast with peak concrete cable protection , sitc cable heat shrink jointing kit of 11 kv grade 95 sq mm , sitc cable jointing kit of 11 kv heat shrink type 95 sq mm , s and fixing on ht pole danger notice plate for ht 11kv , sitc end joint for 1100 volt xlpe cable of size 95 to 120 sqmm , sitc heat shrinkable end joint for 1100 volt size150 to 240 sqmm , sitc heat shrinkable end joint for 1100 volt xlpe cable of size 300 to 400 sqmm , tubes light grade galvanised of size 80 mm , m and l for earthing complete with gi steel earth plate 600mm x 600mm x 6mm , m and l earthing complete with copper earth plate of size 600x600x3 point 15 mm , supply and fixing in repair lightning arrester single pole 11 kv 65 kilo amp , sitc of 11kv sf6 gas 4way rmu 630 amps , sitc of 11kv 630a switch sf6 disconnector outdoor panel , supply and installation and testing 11 kv outdoor type god , sitc of 200 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 160 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 100 kva level 03 transformer 11kv on ht and 433 volts on lt side , taking out of transformers 50 kva to 200 kva depositin in mes yeard , taking out old unsv ht ug cable of any size , dismantling air break gang operated switches , xlpe cable, working voltage from 3.3 kv up to and including 33 kv (v2) isi marked to is 7098 (part 2) (q2)

CTN :45279670 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For corrigendum : supply of excavation soft and loose soil not exceeding 1 point 5 metre deep and wide , returning filling in soilsspreading leveling watering and well ramming , removal of surplus soils not exceeding 50 mtr distance , m and l for sand filling with clean dry fine sand unwashed , s and l un reinforced pre cast with peak concrete cable protection , sitc cable heat shrink jointing kit of 11 kv grade 95 sq mm , sitc cable jointing kit of 11 kv heat shrink type 95 sq mm , s and fixing on ht pole danger notice plate for ht 11kv , sitc end joint for 1100 volt xlpe cable of size 95 to 120 sqmm , sitc heat shrinkable end joint for 1100 volt size150 to 240 sqmm , sitc heat shrinkable end joint for 1100 volt xlpe cable of size 300 to 400 sqmm , tubes light grade galvanised of size 80 mm , m and l for earthing complete with gi steel earth plate 600mm x 600mm x 6mm , m and l earthing complete with copper earth plate of size 600x600x3 point 15 mm , m and l for ht heat shrinkable straight through jointing kit size 95 sqmm , supply and fixing in repair lightning arrester single pole 11 kv 65 kilo amp , sitc of 11kv sf6 gas 4way rmu 630 amps , sitc of 11kv 630a switch sf6 disconnector outdoor panel , supply erecting and fixing steel tubular swaged pole 410 sp55 11 mtr long , supply and installation and testing 11 kv outdoor type god , sitc of 100 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 125 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 160 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 250 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 500 kva level 03 transformer 11kv on ht and 433 volts on lt side , taking out of transformers 100 kva to 500 kva depositin in mes yeard , taking out old unsv ht ug cable of any size , dismantling air break gang operated switches , xlpe cable, working voltage from 3.3 kv up to and including 33 kv (v2) isi marked to is 7098 (part 2) (q2)

State Government

CTN :45376295 Due date: 06 Jun, 202606 Jun, 2026 5.99 Lacs
Tender For repair maintenance of various e m services in various delhi govt offices under ae e emsd ii giri nagar kalkaji new delhi sh supply, installation, testing and commissioning of lightning arrester for surge protection l t panel earthing ups ac replacement of faulty led fittings

Central Government/Public Sector

CTN :45374834 Due date: 12 Jun, 202612 Jun, 2026 9.95 Lacs
Tender For repair/ maint of lt over head line, lt pole and busbar with connected accessories at hq igar (e) srikona. - schedule a part - i, supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 25 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 35 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 50 sqmm 3.5 core, complete including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 70 sqmm 3.5 core including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., m&l for preparation of surfaces of pole for painting of steel tubular pole,vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by engineer-in-charge on poles and numbering with writing letters or figures(block) complete all as directed., s&f street light control panel confirming to ip 66 protection mounted on wall/pole/pcc foundation with suitable ms clamps & nut bolts etc installation and testing including 01 no mcb tpn 63 amp (incomer),01 no contactor 63 amp 3 pole , 230v 3p module astronomical time switch , bakelite fuse fitting with 2 a hrc fuse,indicaion lamp,mounting lugs,panel lock,hinged door,auto manual selector switch 6 amp, detachable mounting din channel,supply monitoring device complete all as specified and directed, supply and fix high efficient ip-66 led street light 70 watt with high power leds, having aluminium pressure die cost housing and pc cover in the front and lens for light distribitioon and saving of energy efficient including service bracket and making of fixing arrengement all as direct by engr -in-charge., labour only for stringing loose lt line alumunium conductors as per direction of engr- in -charge, supply and fixing lt line separator 1100 volts of approved brand and quality, supplying and erection of 100 mm x 65 mm pin insulator complete with g. i. spindle and nuts etc as required .

Central Government/Public Sector

CTN :45365796 Due date: 27 Jun, 202627 Jun, 2026 11.50 Lacs
Tender For repair resurfacing of certain roads and connected items at bd bari mil stn - m&l preparing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with wire brush/brooms and finally fanning the cleaned surface with gunny bags or by mechanical blower to remove all loose dirt etc to black top surfaces, and applying evenly a priming/tack (viscosity grade paving bitumen of grade vg-10) @ 5 kg per 10 sqm to road surface bituminous asphaltic semi dense concrete consolidated thickness 30 mm with stone chippings graded aggregate with 5.5% of binder content by weight of total mix, (viscosity grade paving bitumen of grade vg-30) and 4% stone dust conforming to required specification for filler as per irc-95, 1987 (filler) by weight of mix, prepared in hot mix plant, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and rolled with 8 to 10 tone power roller completed all as specified and as directed., m&l for repair to potholes, any depth ,not exceeding 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, path etc, cutting around edges to at least 25mm in depth, making good by filling in screened and graded road metal, watering and well ramming, applying tack coat with (viscosity grade paving bitumen of grade vg-10) @ 10.0 kg per 10 sqm of surface putting in & including premixed bituminous macadam, well rammed and sealed with binder 9.80 kg/sqm, blinded with 0.09 cum of stone chippings, 6.3mm size and again well rammed, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and using with 8 to 12 tonne power roller (including supply of premixed macadam, binder and chippings),completed all as specified and as directed., premix bituminous macadam laid / rolled and compacted using 8 to 12 tonne power roller to required gradient and camber, with broken stone graded aggregate with 4% of paving bitumen binder of viscosity grade vg-30 grade by weight of toal mix (consolidated thickness 75mm or less) completed all as specified and as directed., m&l providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completed all as specified and as directed., m&l for marking lines 2.5 mm thick, dashes arrows etc of any description n. exc 10cm width/girth on road surface using hot applied thermo plastic road marking paint of approved colour confirming to bs-3262-1989 with special applicator machine all as per manufacturere instruction completed all as specified and as directed., supply and fix solar cat eye (green/red) aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency mono rystafie solar panel 2.4v/ 0.3 watt one ni-ed rechargeable battery (1.2v/ 1600ma) consisting of super bright led with 10,000 to 18,000 mcd completed as per manufactures instructions etc completed all as specified and as directed., supply and fixing metal tubular dealineator made out of abs round body fitted with 2 nos 65 mm dia highly reflective reflectors made out of and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in pcc 1:2:4 (150x150x300mm) type b1 complete all as specified and directed, s&f manufacturing, supplying and fixing retro reflective mandatory/ regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered wi

Central Government/Public Sector

CTN :45382837 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking capacity with

CTN :45344756 Due date: 09 Jun, 202609 Jun, 2026 30.00 Lacs
Tender For : work of maintenance of various equipment’s at 33 kv control panel/ vcb/line isolator including retro fitting of damaged protection relay and maintenance & repair work of 11 kv vcb along with erathing of power t/f & control room & inreacting capcity of power t/f (at 33/11 kv quila s/s) etc. in different 33/11 kv s/s under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2025-2026).

State Government

CTN :45313570 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required

State Government

CTN :45315676 Due date: 11 Jun, 202611 Jun, 2026 13.77 Crore
Tender For establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
 Loading, Please wait...

Connect us via What's Up