Web Analytics Made Easy - StatCounter

Automatic Control Panel Tenders

Get complete information related to latest Automatic Control Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Automatic Control Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Automatic Control Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45741283 Due date: 09 Jul, 202609 Jul, 2026 1.42 Lacs
Tender For repairs of automatic control panels installed at ahus of the convention centre jammu.

Central Government/Public Sector

CTN :45719626 Due date: 18 Jul, 202618 Jul, 2026 40.00 Lacs
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab

CTN :45732559 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For repair and restoration of wss parkot kamand in gp kamand in anni block anni distt. kullu (hp). (sh: providing and fixing barbed wire fencing around storage tank junibag 15000 itrs. cap., dagsari 12000 itrs. cap. & dalot 12000 ltrs. cap. and fixing of ms fabricated protection panel on storage tank.).

CTN :45704495 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; annual maintenance contract of main panel protection reley avr system for season 2026 27; buyer

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

State Government

CTN :45713795 Due date: 18 Jul, 202618 Jul, 2026 4.98 Lacs
Tender For supply, installation, testing and commissioning of dewatering submersible 20 hp pump, automatic control panel with water level sensors in adit-ii hrt of bhep ii

Central Government And Public Sector

CTN :45279869 Due date: 29 Jun, 202629 Jun, 2026 2.90 Lacs
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission

Central Government/Public Sector

CTN :45365796 Due date: 04 Jul, 202604 Jul, 2026 11.50 Lacs
Tender For corrigendum : repair resurfacing of certain roads and connected items at bd bari mil stn - m&l preparing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with wire brush/brooms and finally fanning the cleaned surface with gunny bags or by mechanical blower to remove all loose dirt etc to black top surfaces, and applying evenly a priming/tack (viscosity grade paving bitumen of grade vg-10) @ 5 kg per 10 sqm to road surface bituminous asphaltic semi dense concrete consolidated thickness 30 mm with stone chippings graded aggregate with 5.5% of binder content by weight of total mix, (viscosity grade paving bitumen of grade vg-30) and 4% stone dust conforming to required specification for filler as per irc-95, 1987 (filler) by weight of mix, prepared in hot mix plant, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and rolled with 8 to 10 tone power roller completed all as specified and as directed., m&l for repair to potholes, any depth ,not exceeding 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, path etc, cutting around edges to at least 25mm in depth, making good by filling in screened and graded road metal, watering and well ramming, applying tack coat with (viscosity grade paving bitumen of grade vg-10) @ 10.0 kg per 10 sqm of surface putting in & including premixed bituminous macadam, well rammed and sealed with binder 9.80 kg/sqm, blinded with 0.09 cum of stone chippings, 6.3mm size and again well rammed, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and using with 8 to 12 tonne power roller (including supply of premixed macadam, binder and chippings),completed all as specified and as directed., premix bituminous macadam laid / rolled and compacted using 8 to 12 tonne power roller to required gradient and camber, with broken stone graded aggregate with 4% of paving bitumen binder of viscosity grade vg-30 grade by weight of toal mix (consolidated thickness 75mm or less) completed all as specified and as directed., m&l providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completed all as specified and as directed., m&l for marking lines 2.5 mm thick, dashes arrows etc of any description n. exc 10cm width/girth on road surface using hot applied thermo plastic road marking paint of approved colour confirming to bs-3262-1989 with special applicator machine all as per manufacturere instruction completed all as specified and as directed., supply and fix solar cat eye (green/red) aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency mono rystafie solar panel 2.4v/ 0.3 watt one ni-ed rechargeable battery (1.2v/ 1600ma) consisting of super bright led with 10,000 to 18,000 mcd completed as per manufactures instructions etc completed all as specified and as directed., supply and fixing metal tubular dealineator made out of abs round body fitted with 2 nos 65 mm dia highly reflective reflectors made out of and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in pcc 1:2:4 (150x150x300mm) type b1 complete all as specified and directed, s&f manufacturing, supplying and fixing retro reflective mandatory/ regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fu

CTN :45671759 Due date: 01 Jul, 202601 Jul, 2026 55.80 Lacs
Tender For providing and supplying spare parts for all type of borewell as per requirement in b.n.c.m.c. area 2026-2027 - providing and supplying spare parts for all type of borewell as per requirment in bncmc area 2026-2027, :item no. 1 : providing and laying in trenches following mm dia. medium grade having embossed as isi mark galvanised iron pipes ?of kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats including removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. pwd ssr 2022-2023 pg no 268 41.20,41.21 25 mm dia, 32mm dia, item no. 2 : providing and supplying blue mdpe pipes conforming to iso 4427:1996 manufactured from virgin resin pe 80 food grade compounded raw material having blue colour only with quality assurance certificate from quality agencies like wrc / cipet (india) / dvgm / kiwa / spgn etc. for usage in drinking water system. the cost shall include testing of all materials, inspection charges, transportation up to store, transit insurance, loading, as specified and directed, unloading,stacking excluding gst levied by goi & gom in all respect, etc. complete as specified and directed.mjp dsr 2023-24 pg no 128/1/b 25 mm dia, 50 mm dia, item no 3 providing, erecting and giving test of centrifugal monoblock pump set conforming to is 9079 operating at 2900 rpm with ci impeller, priming funnel, cock, suitable flanges at suction and delivery side. pump shall have common shaft for pump and motor. motor shall be suitable for working on 415 v 10%, 3 ph, 50 hz a.c. supply. motor shall be tefc type. pump set shall be suitable for working at various discharge and head requirements. pump shall be erected on provided c.c. foundation block with suitable foundation bolts grouted in c.c. foundation block.centrifugal monoblock pump set (single stage) mjp mech.csr 2023-24 pg no 5 pm 2-1-5] 10 hp, item no 4 : supplying and erecting submersible pump 150 mm dia (with bronze / stainless steel (cf8m) impeller) up to 8 stages mjp mech.csr 2023-24 pg no 01 pm 1-2-1,pm 1-2-2] 1.5 hp, 2.0 hp, item no 5 supplying & erecting pressure booster pump, single phase, 50c/s, a.c.supply of 0.75 kw/ 1 h.p., with discharge of 480 to 13 lpm for 10 to 50 mtrhead & 25 mm suction/ 25 mm delivery pipe, for domestic pressure boosting applications pwd ele csr 2022-2023 pg no 206 12-6-2, item no 6 supplying & erecting pressure booster pump, single phase, 50c/s, a.c.supply of 0.375 kw/ 0.5 h.p., with discharge of 120 to 12 lpm for 10 to 40mtr head & 25 mm suction/ 25 mm delivery pipe, for domestic pressure boosting applications. pwd ele csr 2022-2023 pg no 206 12-6-1, item no. 7 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible/centrifugal pump set up to 3 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. pwd ele csr 2022-2023 pg no 220 12-4-20, item no.8 supplying & erecting automatic control panel for 3 phase , 415 volt, a.c, submersible/centrifugal pump set up to 7.5 hp consisting of dol starter having relay range 9-14 amp,s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc .pwd ele csr 2022-2023 pg no 204 12-4-17, item no. 9 supplying and erecting d.o.l. starter 400v. 3 phase, 50cycles with no volt coil and overload element with necessarymaterials and connected to supply for 10 h.p., item no 10 supplying & erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.pwd ele csr 2022-2023 pg no 220 12-4-8, item no. 11 supplying, erecting & terminatin

CTN :45690396 Due date: 02 Jul, 202602 Jul, 2026 25.59 Lacs
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &