Tender For supply of 1.compact flourescent light fitting single without 4 pin 11 w cfl lamp & electronic ballast. the fitting is to be provided with holder. the complete fitting shall confirming to rcf drawing no. cc 76215 alt-d.2.fitting side lamp complete, suitable for passenger brakes van, confirming to rdso drg. no.skel- 4094 with alteration -a. the colour convention of side lamp fitting is out side black colour and inside white colour. the fitting shall be supplied without lamp/bulb.3.night light fitting icf drg. no. icf/s.k. 7-6-020 col .iii alt. 'm' or latest for screw type lamp (without lamp).4.alarm chain pull indication light fitting conforming to rdso drg no skel-3911 [rev-1]alt-c with the following requirments [1]the outside of light fitting should be finished in synthetic enamel red paint to is 2932[2] the lens shall be clear and colourless [as per item -4 of rdso drg no skel3911] [3] holder shall be screw type e-27 [4] the cable entry hole shall be 20 mm dia instead of 11 mm dia.indicated in the drawing [5] holes shall be provided to suit 20 mm dia grommets.5.led foot light as per following details:- i) power: 4 watt. ii) input voltage range: 90-140v dc. iii) light colour: warm white. iv) color temperature: 3000k. v) ligh source: high efficiency long life smd led. vi)material: aluminium die cast. vii) finish type: powder coated. viii) shed colour: white. ix) mounting: wall mount. x) installation type: flush mount. xi) switch: no. xii) product dimention: a) length: 85 x 5mm.b) width: 85?5mm. c) height: 30?5mm. xii) cut-out(c): 70 x 70mm. xiii) indoor/outdoor usage: indoor. xiv) lighting method: down light. make : similar to victoria brand, model no. vlfl4.
Tender For supply of supply of spares for addressable alarm system d d - 1 loop addressable fire alarm control panel , supply of addressable multi sensor smoke detectors , supply of electronic footer cum flasher , supply of addressable control module for hooter , supply of addressable manual call point , supply of gsm based telephone auto dialer , supply of addressable beam detector
Tender For supply of portable combustible gas detector -range: 0-10% lel & 0-100%lel for gases hc/combustiblemeasuringgascombustiblegases (calibration for methane or iso-butane)suction by in built pumpalarm: 2 alarm levelsbatteries4xaa orrechargeable battery➤ battery life approx.10hoursdisplay electronic digital displayweather protection:ip-67intrinsically safe certified, for hc/combustible gasesresponse time within 30seconds to get 90% indicationcertification: certified bypeso competent standard accessories withinstrument should be provided fully calibrated along with calibration certificate.detection range/ sensorranges:0 100% lel
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp