Get complete information related to latest Autopsy Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Autopsy Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Autopsy Equipment Tenders.
Tender For supply of various spare parts for psi department - input contactor, add on aux contact, dvr contactor, auxiliary contactor, air break, in open execution, auxiliary contactor, auxiliary contactor, auxiliary contactor, air break, in open execution, auxiliary contactor with surge suppressor, auxiliary contactor with surge varistors, open/close contactor, dc supply supvn aux contactor, aux contactor, dc contactor, dc contactor, dc contactor, aux contactor, dc contactor, aux contactor, aux. contactor, add on contact block, add on contact block, add on contact block, auxiliary contactor, auxiliary contactor, fcbcs i/p contactor, dvr contactor, dvr contactor, bch i/p contactors, bch i/p contactors, contactor, contactor, contactor, dcdb incomer contactor, winding temperature indicator, oil temperature indicator, winding temperature indicator, oil temperature indicator, remote wti/oti, for wdg temp,oil temp, for tap position, winding temperature, fire alarm, mpcb, time delay relay, rtcc supply, indication supply, out of step, trip circuit supervision, trafo fault relay, dcdb earth fault relay, transformer protection relay, mtr,86, relay, auxiliary relay, aux relay, 8 step apfc relay with rs-485 port, led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (10mm), 25 mm ring, door limit switch, 2.5sqmm, open/close interlock release emergency stop p.b, release emergency stop p.b, push button with spring return, push button actuator red mushroom head nonilluminated, for alarm cancellation, raise/lower command/lamp test push button, overload relay, c/o relay, bridge rectifier, counter, smps, mechnical interlock (3 lock+2 key), i/p voltmeter, o/p voltmeter, digital voltmeter with builtin selector switch, dc voltmeter, digital voltmeter with inbuilt selecter switch, digital voltmeter with inbuilt selecter switch, anolog voltmeter, o/p ammeter, battery ammeter, digital ameter with builtin selector switch size 96x96sqmm, 3 , ammeter with inbuilt selector switch., dc voltage monitoring relay, voltage monitor relay with phase sequence, voltage monitoring relay nominal, voltage monitoring relay (phase & voltage control), fcbc o/p relay, fcbc o/p relay, fcbc boost relay, fcbc voltage sensing relay, relay (air breaker auxiliary contactor relay) (relay with base), multi function meter ctr-1/5a,cl-1 with comm.port rs-485nominal voltage, 415v ac aux voltage-230v ac/ 125-250v having following parameter v, a, f, pf, power, kwh, with tod etc., multifuction meter with builtin selector switch, 230vac aux supply;96sqmm, rs-485portcl-1, digital kwh meter., digital kwh meter., digital kwh meter., on delay timer, on delay timer, on delay timer, on delay timer, hrc fuse (rectifier fuse), bs type hrc bolted/closed slot, fuse base bs type hrc bolted /off settag, bs type hrc bolted/closed slot, control circuit fuse, control fuse with base, control fuse with base, fuse link, control hbc fuse, control hbc fuse base, input fuses, rectifier fuses, capacitor fuse, fuse for lighting, motor fuse, local/remote switch, breaker control switch (trip neutral close), motor switch, auto/manual selector switch, cooler auto/manual selector, door switch, local/remote, breaker cotrol switch with key (spring return), auto/manual selector switch, auto/manual selector switch, auto/main selector switch, local/remote selector switch, vcb auxiliary switch, local/remote switch, interlock switch with mech. lock, auxialry switch, charger on/off switch- cam type front panel mounting knob handle, ac i/p voltage selector switch, breaker control switch, miniature circuit breaker, miniature cir
Tender For corrigendum : establishment of integrated analytical laboratory for demil plant - hot air oven, magnetic stirrer, heating cooling circulator, rotary evaporator with chiller and vacuum pump, ultrasonic cleaner, high speed orbital shaker, vacuum pump, peristaltic pump, benchtop ph meter with orp electrode & necessary buffers, electrode storage solution & electrode cleaning solution, dissolved oxygen meter, turbidity meter, bench top multi-parameter tester (conductivity, tds, salinity, ph), bod incubator, cod digestor system, vortex mixer, effluent sampling manifold (esm) with controlled cobustion chamber (ccc), analytical balance, laboratory balance, mini centrifuge machine, gyro shaker, melting point apparatus, electric bunsen burner, deep freezer, laboratory rrefrigerator, ultra-pure water purification system, muffle furnace, double distillation unit, probe sonicator, heating mantles, systematic design, partitions, equipment console with work and storage modules, chemical reagent console with work and storage modules, instrument console with work and storage modules, overhead storage console, extended office console, office console, file storage console, record management console, back positioning module, fire protection modules, fume closet, exhaust manifold, power reserve (40 kva), elemental (chnso)analyzer, inductively coupled plasma - mass spectrometer (icp-ms), microwave digestion system, amc cost for 1st year after expiry of warranty period, amc cost for 2nd year after expiry of warranty period, amc cost for 3rd year after expiry of warranty period
Tender For corrigendum : purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val
Tender For supply of point - of - care hemoglobinometer (q2) ( pac only ) , dengue rapid test kits (q2) ( pac only ) , glucometer , glucometer testing strips , strips for digital haemolglobinometer , rapid pregnancy testing kit , specimen collection bottle , spirit lamp , test tube holder rack , test tubes , glass slide box of 25 slides , yellow strips for micropipette , hypochlorite solution 200 ml , acetic acid solution , benedicts solution 500 ml , n10 hydrochloric acid , slide drying rack , test tube holding clamp , widal test kit carbon , glass rods , methylated spirit 200 ml , urine strips for albumin and sugar reagent covered protected with nylon mesh pack of 25 , urine strips for sugar albumin ph ketone and blood reagent covered protected wit nylon mesh multi parameter pack of 25 , capillary tube pack of 100 , whatmans filter pack of 100 , cover slip for microscopy , gram stain kit , phenol 5percent 5 litre , handwash 100 ml , anti abd kit , hbsag rapid test kits (q2) ( pac only ) , syphilis rapid test kits (q2) ( pac only ) , hiv rapid test kits (q2)
Tender For supply of medical equipment - pressure injector for cathlab, heart lung machine with tcm, iabp machine, ivus machine for vascular department, ivus ( intra vascular ultrasound system) machine with ffr (fractional flow reserve), video thoracoscopic system 3d & 4k system with accessories, video laryngoscope, hemodynamic monitor, in hand nitric acid delivery system + cylinder compatible with sjicr ventilator + anaesthesia work station, transport monitor, flexible fibre optic bronchoscope- adult & paediatric, cell savers & accessories, act machine, head light with light source, sternal saw, electro surgical cautery machine, twin jar set, bronchial aspiration set., low suction continuous drainage system, high suction continuous drainage system, surgical pendants, o.t. mobile pendants, ceiling drops for cath lab, transport ventilator, ventilators with standard accessories., surgical icu monitors with standard accessories., ot monitor with standard accessories., simple multi parameter monitor with etco2, defibrillator biphasic-mid end, defibrillator biphasic high end with cables & internal paddles- 45 mm,55 mm, 65mm, syringe pumps for- high end, syringe pumps low/mid end, icu cots electrically operated, anesthesia work station ( for ot) with accessories, o.t. table for cardiac surgery, temporary pacemaker single chamber, temporary pacemaker dual chamber, curvilinear probe compatiblefor philips affinity 30 2d echo machine, linear probe compatiblefor philips affinity 30 2d echo machine,, tee probes compatible for philips affinity 30 2decho machine, echo machine with vascular probe and ice connector, ultrasound machine with linear & curvilinear vascular probes, portable echo machine, two d echo machine with adult and pediatric probes
Tender For supply of lab items and reagents - lab items and reagents, aliquot with cap (1.5ml), aliquot without cap (1.5ml), di water (distilled water), dm water (triple lonised), plain vial with cap & sticker, plain vial with clot activator (cap + sticker), collection gel vial with serum separator and clot activator, n/10 hcl, ethanol, sterile water ampoule, hitachi cup (2.0ml), hypochlorite solution 5%, hypochlorite solution 10%, microtip 2-200 ul (yellow), microtip 1000 ul (blue), microtip 5ml, plastic droper 1ml, plastic dropper 2ml, plastic dropper 3ml, plastic dropper 7ml, plastic dropper 10ml, plistic cantainer (1.5ltr. jar), test tubes 10x75mm(glass tube), tissue paper roll, cuvveites, microscope bulb (6v,20w) (should be compatible with make -labomed microscope), microscope lens cleansing solution, microscope lens clearing paper, microscope cover slip (22x22mm), microscope cover slip (22x50mm), leishman stain, heamotoxylene stain, eosin stain, dpx, disposable esr tubes, esr westergren pippet stand (metal) holding capacity 10 tubes, cedar wood oil for microscope, cbc thermal paper roll (should be compatible with make-sysmex xp-300) (57mm x 40mm), bt ct capillary tube, isopropyl alocohol, k3 edta vial with plastic cap + stiker (2ml blood sample), k3 edta vial with plastic cap + stiker (1ml blood sample), p.t. vial, pasteur pipette, rapid pap stain kit, disposable papsmear sample collection kit (2 pc.) sterile, non toxic, pyrogen free, reticulocyte count fluid, acetic acid glacial, luglos iodine solution, sahlis hb meter, semen diluting fluid (125ml), sulfer powder, multi parameter strip (urine test) us-10 (should be compatible with make mission u 500 semiautomed urine analyzer), urine strip (sugar, albumin), urine strip (sugar, albumin, ketone), urine container plastic sterile, wbc diluting fluid, whatmans filter paper no. 1, xylene, sta cuvettes for pt (should be compatible with make -stago start max semiautomated coagulation analyzer), sta iron ball for pt (should be compatible with make - stago start max semiautomated coagulation analyzer), sta nepoptimal for pt (should be compatible with make stago start max semiautomated coagulation analyzer), fintipps 2.5ml (should be compatible with make stago start max semiautomated coagulation analyzer), cbnaat vial, dbs (dried blood spot) card, dbs sample collection kit, culture tube, serum tranport vial (3ml), widal test (slide) 4x5ml, vdrl kit, rpr rapid kit, dengue (ns-1+igm+igg) card test, ra factor slide test reagent, crp slide test reagent, aslo slide test reagent, urine pregnancy card test (upt), comb aids rapid test kit for hiv 1 & 2 principal-dot immunoassay (1x48) nari/niv/ who evaluated sensitivity: 99.5% and specificity: > 98%. supplier must provide negative & positive control free of cost as and when require by the department., tri-dot rapid test kit for hiv 1 & 2 nari/niv/ who evaluated sensitivity: 99.5% and specificity: > 98%. supplier must provide negative & positive control free of cost as and when require by the department., rapid test kit (3rd generation) for hiv 1 & 2 nari/niv/ who evaluated sensitivity: 99.5% and specificity: > 98%., whole blood finger prick rapid test kit for hiv 1 & 2 nari/niv/ who evaluated sensitivity: 99.5% and specificity: > 98%. supplier must provide negative & positive control free of cost as and when require by the department., dual test kit for hiv & syphilis, anti-a antisera, monoclonal blood grouping lgm antibody for slide and tube method for abo blood grouping.vial of 10 ml and storage at +2to +8 c. titer >1:256 with a cell and negative with b cell. avidity should be 4sec. should be validated by nib/ec/aabb/fda., anti b antisera, monoclonal blood grouping lgm antibody for slide and tube method for abo blood grouping. vial of 10 ml each and storage at + 2 to + 8 c. titer >1:256 with b cell and negative with a cell. avidity should be 4sec. should be validated by nib/ec/aabb/fda., anti-ab antisera, monocl