Get complete information related to latest Autosampler Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Autosampler Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Autosampler Spares Tenders.
Tender For automatic mild steel compression testing machine for testing the strength of concrete as peris 14858 : 2000 or its latest, capacity - 2000kn, least count- 0.1 kn or better, accuracy- +/- 1%, accuracy class - class i, for cubes up to 200 mm and cylinders up to dia. 150x300 mm, power source- 230 v, 50 hz, single phase ac supply, display type - digital lcd or led, connectivity- bluetooth/wifi, usb 2.0, rs232 with suitable software and printer interface, required operation manual, carrying case and calibration certificate. (method of testing the concrete cube is as per is : 516 or latest). software features: ucs, youngs modulus, poissons ratio, software shall be capable to plot graph of real time data acquired for load vs. displacement, load vs. time, stress vs. strain. machine shall be able to operate as standalone with digital indicator unit as well as with dedicated data management and analysis software installed in a desktop pc or laptop(ms-windows), peak load, peak stress, unique record number shall be displayed on the digital indicator. [ warranty period: 30 months after the date of delivery ] ]
Tender For standing order/rate contract for supply of instrument materials on door delivery and callup basis at hbl plant sugauli, east champaran and lauriya, west champaran, bihar. - load cell 100 kg strain gauge type, make-avery/ perciamoleen, 4 load cell junction card 4 input 1 out, make-avery/ perciamollen, signal isolater optical isolation type signal input/output 4-20 ma supply 18- 260 vac/vdc, make-radix, signal converter 0-5 a to 4-20 ma supply voltage 18-240 vac/vdc, make-radix./masibus/ p&f, zss controller with its proximity supply voltage 230vac, make-masibus, hall s effect type top roller lift sensors (asd-he-trls-10) and indicatingtransmitters (asd-he-trlit-1005-1-2), make-yu tech, infra red type donnelly chute level sensors, indicators & transmitters, make-yu tech, hall s effect type cane blanket level sensors( asd-he-cbls-10) and indicatingtransmitters (asd-he-cblit-1005-1-2), make-yu tech, pressure transmitter strain gauge type range 0-16 kg/cm2 output 4-20 ma looppowered processe connection 1/2 inch male threaded, make- honywell/ypkogawa, on off controller input signal universal, 2 relay output on set point, make-honywell, size 96x96 supply 230vac, weighing controller/ indicator for beltscale model no=40 bs, make-perciamollen, directional control solenoid operated valve (ng10): 4we 10 d a01-24dg/v, make-hydac, direction control valve, solenoid operated (ng6) type: 4we 6 d a01-24dg/v, make-hydac, pressure relief valve sandwich plate type for ng06(4we 6 d a01-24dg/v), pressure range 210 kg/cm2flow 120 l/min, manual adjustment, fkm sealing, make-hydac, digital pressure indicator cum transmitter range 0- 300 kg/cm2 model no eds 3000, make-hydac/ above equivalent, make parker, strain gauge type dp switch across filter range 0.05kg/cm2, make-hydac/ parker, pnp pproximity switch 2 wire range 15 mm od 30 mm male supply 24 vdc p&f, lvdt range 0-1100 mm probe od 10 mm 1/2 inch threaded connection, out put 4- 20 ma model no. c01-1100-000 make hydac/ above equivalent, make-mts, modelno. rhm1185md601a01, level indicator cum transmitter loop powered output 4-20 ma range 1000mm fluid hydaulic oil, make-parker, part no. 110558, model no. hblt-a1-6u, digital temperature indicator cum transmitter head mount range 0-100c probe od 8 mm loop powered output 4-20 ma, make-hydac/ parker probe length 700mm, solenoid coil connector 4 pin with led indicator, size-20mmx20 mm, lvdt probe connector with 10 mtr cable lid connector type 6 pole, m16 dinfemale type, make-any reputed, plug in power relay with base, coil voltage 24 v dc model no my2n, make-omron, rtd pt100 type length 500mm od 6 mm make thermostatic or any reputed, temperature transmitter cum digital indicator remote field mounting input universal, loop powred, output 4-20 ma, make-rosemount/ honywell/abb/yokogawa/p&f hart enable, 8 channel rtd transmitter input rtd pt100( field interface boards 8 channel linearized rtd/tc input), output 4-20 ma model no-mas-ai-u-o8d-9-1-0, make- masibus, pressure transmitter lvdt type range minus 2 kg/cm2 to 16 kg/cm2 loop powred output 4-20 ma 1/2 inch female threaded process coneection, field mounting hart enable, make-abb/ emerson/ rosemount/ yokogawa, diffrential pressure transmitter range minus2 kg/cm2 to 2 kg/cm2, field mounting process connection 1/2 inch ntp female threaded loop powered 4-20 ma, output hart enable, make-abb/ yokogawa/ rosemount/ emerson, diffrential pressure transmitter range minus 2 kg/cm2 to 2 kg/cm2, field mounting process connection 3 inch flanged diapharm type at higher side loop powered 4-20 ma, output hart enable, make-abb/ yokogawa/ rosemount/emerson, diffrential pressure transmitter range minus 2 kg/cm2 to 2 kg/cm2, field mounting process connection 3 inch flanged diapharm type at both side 4 mtr capilary, loop powered 4-20 ma output hart enable, make-abb/ yokogawa/rosemount/ emerson, perssure gauge burden tube type range 20 kg/cm2 dial size 6 inch process connection 1/2 inch ntp male threaded, make-warri/
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to