Get complete information related to latest Autotitrator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Autotitrator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Autotitrator Tenders.
Tender For corrigendum : providing of calibration services - calibration of intelligent potentiometric autotitrator quantity: 1 number; as per scope of work; as per scope of work; as per scope of work
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For supply of seqstudio cartridge v2 2 boxes , seqstudio cathode buffer container cbc , integrated capillary protector icp , cathode buffer container reservoir septa 20 pack , 96 well plate septa 20 pack , microamp optical 96 well reaction plate , septa, 96 well 20 pk , hi di formamide 4 x 5 ml , bigdye terminator v3.1 cycle sequencing kit 100 reactions , bigdye xterminator kit 2ml each , exosap it 500 reactions ea , nuclease free water not depc treated , adhesive pcr plate seals 100 pc , genescan 600 liz size standard v2.0 800 rxns , 5 inch labeled or unlabeled primer pairs 10000 pmole , truemark msi assay , dpyd , human fwd primer ds , human rev primer ds , human fwd primer hplc , human rev primer hplc , oncomine myeloid research assay , oncomine focus assay each , oncomine comprehensive v3m combo kit , oncomine brca assay manual kit , ion xpress barcode adapters 1 96 , ion ampliseq lib kit plus , ngs reverse transcriptase kit , ion 510 ion 520 ion 530 kit chef 1 sequencing run per initialization , ion 530 chip kit , ion 520 chip kit , ion 510 ion 520 ion 530 kit chef 2 sequencing runs per initialization , ion 540 chef kit , ion 540 chip kit , ion 16s metagenomics kit , ion plus fragment library kit each , ion ampliseq microbiome health 48 rxn or pnl in 540 chip , alltype fastplex 11 loci kit , ion 520 ion 530 ext kit chef , oncomine cftna lung assay , tag sequencing bc set 1 24 , magmax cellfree total na isolation , ion xpress barcode adapters 1 16 kit , ion xpress barcode adapters 17 32 kit , ion xpress barcode adapters 33 48 kit , ion ampliseq library kit plus , microamp optical 96 well reaction plate , microamp fast optical 96 well reaction plate , microamp optical adhesive film , microamp adhesive film , microamp compression pad , ion library taqman quantitation kit , qubit dsdna quantification assay kits 500rxn , naoh 1n , tris hcl ph 8,1m , qubitrna br assay kits , qubit fluorometer system verification assay kits , qubit rna iq assay kits , qubit rna hs assay kits , qubit rna xr assay kits , magmax cell free dna isolation kit
Tender For providing of customized annual maintenance contract/cmc for pre-owned products - autotitrators; metrohm 9050c26b72 - lining up annual maintenance contract of metrohm auto titrators for three years with m/s metrohm india private limited, on proprietary basis line item 10 - 1styr annual maintenance contract for 5 metrohm autotitrators;..,customized annual maintenance contract/cmc for pre-owned products - autotitrators; metrohm 9050c26b72 - lining up annual maintenance contract of metrohm auto titrators for three years with m/s metrohm india private limited, on proprietary basis line item 20 - 2nd yr annual maintenance contract for 5 metrohm autotitrator..,customized annual maintenance contract/cmc for pre-owned products - autotitrators; metrohm 9050c26b72 - lining up annual maintenance contract of metrohm auto titrators for three years with m/s metrohm india private limited, on proprietary basis line item 30-3rd yr annual maintenance contract for 5 metrohm autotitrators; ..
Tender For supply of reaction frame of 150 ton capacity for hydraulic jack testing with load cell & digital display reaction frame capacity 150 ton safe over load 200 ton height - 1000 mm, hyd jack testing width 500 mm hyd jack testing. [ warranty period: 30 months after the date of delivery ] ]
Tender For e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - "rh +k phenotyping glass bead cassettestechnical specification:1.cassttes should contain 6 columns filled with glass bead as filtration media 2.1st column to 5th column should be prefilled with monoclonal antisera such as anti c, anti e, anti c, anti e, anti k respectively and 6th column is 'control' column. 3.peg should be present in the columns as enhancer to increase uptake of antibody 4. assay time should be as per manufacturer's guideline / brochure 5. mixed field reaction /double cell population should be detected " , "ahg poly specific glass bead cassettes technical specification:1. cassettes should contain 6 columns filled with glass beads filtration media 2. all column should prefilled with ahg reagent (anti igg , anti c3d)3. assay time should be as per manufacturer's guideline / brochure 4. mixed filled reaction /double cell population should be detected" , "blood grouping (forward & reverse grouping) glass bead cassettes technical specification: 1. cassettes should contain 6 columns filled with glass bead as filtration media 2. 1st to 3rd colums should be prefilled with monoclonal antisera with a serial of anti a, anti b, anti d respectively and rest 3 colums contain 1 for 'control' and 2 colums for reverse grouping with variable serial.3. peg should be present in the columns as enhancer to increase uptake of antibody 4. centrifugation time should be as per manufacturer's guideline5. mixed field reaction /double cell population should be detected" , "monoclonal antisera for extended rh+k phenotypinganti c technical specification:anti c sera should be monoclonal anti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti ctechnical specification:anti c sera should be monoclonalanti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti e technical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti etechnical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti k (kell)technical specification:anti k sera should be monoclonal anti k sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "panel for antibody 3 cell screening applicable to conventional test tube method and glass bead cassettes technical specification: 1. cell panel should be 2%-5% of rbc suspended in saline 2. cell panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4. dose depended antigens (like mns, duffy etc) should be present in homozygous as per criteria of antibody screening test 5. cell panel should be compatible for enzyme treatment 6. pack size should be as per manufacturer's guideline / brochure " , "panel for antibody 3 cell screening applicable to gel card technical specification:1.cell panel should be 0.8%-1% of rbc suspended in low ionic strength saline2. cell panel should be compatible with gel card of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4.dose depende
Tender For e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - "rh +k phenotyping gel card technical specification:1. cassettes should contain 6 columns filled with sephadex gel as filtration media 2. 1st column to 5th column should be prefilled with monoclonal antisera such as anti c, anti c, anti e, anti e, anti k respectively and 6th column is 'control' column. 3. assay time should be as per manufacturer's guideline / brochure 4. mixed field reaction /double cell population should be detected", "diluents for rh +k phenotyping gel card"