Get complete information related to latest Auxiliary Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auxiliary Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auxiliary Contactor Tenders.
Tender For supply of auxiliarycontactor for pantograph and vcb [pos no.130.1, 136.4] clw spec no.clw/es/3/0040, alt-a. item type ref.lc1d09fd, make: schneider electric. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For supply of repair and maintenance of hand held search light , repair and maintenance of hand held metal detector , repair and maintenance of trail camera with accessories , repair and maintenance of bullet proof long tall morcha , repair and maintenance of veh mounted search light , repair and maintenance of bullet proof short morcha , repair and maintenance of under veh search mirror , repair and maintenance of portable tyre killer , repair and maintenance of ptz camera day and ni vision for cctv , repair and maintenance of adopter for cameras , repair and maintenance of camera poe cord , repair and maintenance of dc adopter for 17 poe switch , repair and maintenance of nvr repair , repair and maintenance of adopter for ote , repair and maintenance of ofc patch cords , repair and maintenance of utp drum , repair and maintenance of 12 v 7 ah bty for ups , repair and maintenance of junction box with mounting caps , repair and maintenance of power cable , repair and maintenance of terminal box , repair and maintenance of optical fiber cable
Tender For corrigendum : set of auxiliarycontactor for wag-9 loco. set consisting of 03 items in 3 nos-- (1) auxiliary contact for panto, 9 amps, 3 pole, dc contactor,110v dc, type-lcid 09 fd, qty.= 01 no. to clws spec.no.-clw/es/3/0040 (alt.-c). (2) aux. contactor for mr blower with 110v dc, 4 pole, 25 amp, type lcid 128 fd, qty.= 01 no. to clws spec. no.- clw/es/3/0012 (alt.-h) . (3) aux. contactor for power supply with 110 v dc, 4 pole, 25 amp, type- lcid 128 fd, qty.= 01 no. to clws spec. no.- clw/es/3/0012 (alt.-h) . [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For supply of havolr40a over load relay 40 amp , b1sr00297 oil seal for gear box , havolr18a over load relay 18 amps , bchtm220v timer , f1s191339 crusher unit mounting bolt with nut lock nut and washer , 500ri0003 return idler 60cm x 9cm , unt25c013 auxiliarycontactor dc 2no 2nc , 500bc2a15 high speed coupling with nut bolt motor gear box , 500bc4a16 low speed coupling with nut bolt g box pulley , 500110002 impact idler roller , 1200240911 fuel filter element , 1200240912 fuel filter element , 605411880008 lubricant oil filter , 6h 4 11 02 000 p21109230192 air filter sec , p21109230191 air filter primary , 500bf0021 belt fastner , 500bw0012 500bw00rf return conveyor belt 23 mtr including belt fastner , 500bw0012 500bw00mf main belt 30 mtr x 05 x 10mm crushing unit to screen * /bid number : gem/2026/b/7672189 + /dated: 26-06-2026 ' ' / bid document 1 / 20
Tender For repair/replacement of security light,timer panel, solar street light,street light poles,flood light,junction box,acsr conductor and connected allied services at out pockets under ge dinjan no.2
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For supply of contactor for head light, auxiliaries compressor and gusp (pos no. 48.2, 338, 218.2) and auxiliarycontactor for contactor auxiliaries (pos no. 52.3, 52.6), type s-163 as per clw specification no.clw/es/3/0034 alt.-c [abb document no.hbtb585402 r0821]. [ warranty period: 30 months after the date of delivery ] ]