Get complete information related to latest Av Receiver Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Av Receiver Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Av Receiver Tenders.
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin
Tender For armo of international boys hostel of 500 capacity and food court including water supply, sanitary installation, internal electrical installation, fire fighting system, fire alarm system, sub-station, lift, dg sets, cctv, ro plants, access control system and solar pv system at iari, pusa, new delhi. (sh:- supply, installation, testing and commissioning of wireless data receiver cum digital data transmitter with capacitance based battery powered data signal in food court area.)subwork/packages:sitc of wireless data receiver cum digital data transmitter with capacitance based battery powered data signal in food court area
Tender For supply of supply of three way cinema screen speaker system , supply of subwoofer specially developed for playback of digital audio , supply of nine point four chaneel eight k avreceiver , supply of active cinema crossover designed for cinema audio , supply of cinema surround speaker designed for immersive sound playback , supply of two way passive speaker with frequency , supply of two way surround speaker system with frequency , supply of quad channel power amplifier with frequency , supply of eight in eight out digital speaker processor , supply of dual channel power amplifier with output power , supply of dual channel power amplifier with frequency , supply of preset selector unit , supply of thirty six u rack , supply of bulk cables and connectors , installation and commisioning
Tender For supply of web mounted transmitter and receiver coil assembly with tx,rx coils for 21khz and 25khz with 15m cable length for high availability single section digital axle counter [hassdac] ggtronics make. as per rdso spec.no rdso/spn/177/2012 ver 3.0 or latest. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply specification for 20kw digital ready (hd radio & drm+) vhf fm solid-state mosfet technology based broadcast transmitter in (1+1) configuration with automatic changeover unit and associated equipments/items -regarding industry feedback & budgetary quotes.-one set of 20kw digital ready (hd radio & drm+) vhf fm solid-state mosfet, one set of 20kw digital ready (hd radio & drm+) vhf fm solid-state mosfet, one set of interface card for digital operation of fm transmitter including importer/exporter for hd operation
Tender For supply specification for 10kw digital ready (hd radio & drm+) vhf fm solid-state mosfet technology based broadcast transmitter in (1+1) configuration with automatic changeover unit and associated equipments/items-regarding industry feedback & budgetary quotes
Tender For tender for supply of pressure transmitter - compressor discharge lube oil , temperature element , solenoid valve body capacity control , hot gas bypass solenoid valve body 240 ra 8 t7t , pilot operated solenoid valve , evm plunger for capacity control solenoid valve , level switch , oil level switch , digital flow rate cum totaliser switch , auxillary contactor 24v dc , add-on block for auxillary contactor , aux. contactor-2no- 2nc coil voltage 24 vdc , under voltage relay 3 ph minilec vct-d2 , power contactor 230vac siemens 3tf32 00-0am0 , human machine interface hmi-display , digital input card for plc , analogyl input card for plc , digital output card for plc , 3 core cable for 33a 440v , zink plugs for sea water coolers , filter elements sets , fine filter element set , filter elements sets , pressure sensors , temperature sensors , analyzer o2 zro2 24vdc , type 6150 nitrogen membrane module tag no. mm-20 , ball valve size 2-1-8inch , hydrocarbon detectors testo 316-2
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For supply of lab equipments - purchase of lab equipments, ask modulation and demodulation kitspecifications: message signal1: 8-bit variable data,amplitude 5v. message signal 2: debounced data, amplitude low (0) and high (5 v). message signal 3: fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz, amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. modulator type: switching modulator using analog switch / transistor switching ic. demodulator: envelope detector and lpf. comparator: lm311 based. supply voltage (board): +12 v, +5 v dc. supply current: 100 ma minimum. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fiber optic communication trainer kitspecifications:power supply: 230 v ac 10%, 50 hz mains operation. built-in regulated power supply. optical transmitters: led transmitter: 660 nm. optical receivers: phototransistor / pin photodiode receiver. built-in signal conditioning and amplifier circuits. audio power amplifier with speaker/headphone output. comparator / pulse shaping circuit for digital signal recovery. test points for cro observation and signal monitoring. fiber media: multimode plastic optical fiber (pof). fiber patch cords with connectors. signal sources: built-in sine wave generator. built-in square wave / digital pulse generator. voice signal input through built-in microphone/audio source. trainer features: separate transmitter and receiver sections. on-board test points for signal observation. led indicators for signal monitoring. fault simulation facility. compact tabletop modular design. circuit diagram printed on pcb. bandwidth: analog bandwidth: up to 350 khz. digital bandwidth: up to 2.5 mhz. controls: variable signal amplitude control. variable frequency control. optical intensity adjustment. standard accessories: patch cords and connectors. power cord. audio connecting cable. user manual.