Tender For rohtak town annual maintenance works for storm water - repairing of panel board including connector and labour etc. / job work for repair of panal board of 100 hp and conactor, thimble wiring, coiles etc. with the help of electrician and manual labour at harizan basti disposal and all other works contingent thereto complete in all respect.
Tender For repair/maint of unserviceable internal wiring electrical fittings, ceiling/ exhaust fans/ summer appliances, day to day electrical complaints at d, e, f type officers qtrs, scientist hostel, dlomi and swimming pool at drdo township kbagh hyderabad
Tender For corrigendum : repair maint of internal wiring incl submain ckt wiring alongwith associated works at various md accn at af stn singarsi under age i af stn singarsi
Tender For corrigendum : repair/maintenance of main distribution boards, service connections, submain wiring, building security lights, building earthing and connected works under ge (east) mathura
Tender For corrigendum : comprehensive repair and maintenance of lightning protection of building earthing and wiring and other connected items under ge babina
Tender For corrigendum : special repair to tiling, plastering, joinery and internal wiring at anteroom, bed room and dinning room at building no p-12 mb area and certain rev and minor work in the area of age b/r-i under ge (west) jabalpur
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For repair to drains, compound wall, repair and desilting, cleaning/ replacement of float valve oh tanks, repair and maint of internal wiring, ceiling fan, security light along with allied wks in sila grn under age reasi of ge nagrota