Get complete information related to latest Bacterial Culture Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bacterial Culture Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bacterial Culture Tenders.
Tender For supply of chrome uti agar plate. spec: 1. it should be ready made solid culture media in 90 mm disposable petri plate used for bacterialculture with minimum 4 mm thickness. 2. should be suitable for isolation and enumeration of bacteria from clinical specimens. 3. media should contain selective ingredients for inhibiting swarming of proteus and isolation of major uropathogens- gnb and gpc both. 4. manufacturer firm should have iso/bis+who gmp/european ce/fda/any recognised international council approval certification. 5. media should have a minimum shelf life of 3 months. 6. biomedical waste generated from the plastic petri plate should not generate carcinogenic byproducts on incineration/autoclaving/microwaving. 7. performance should be demonstrated to the satisfaction of end user with each new batch supplied. 8. it demonstrates good batch-to-batch reproducibility.( pack of 50 plates)[ai(2025-26) , item code no.s-60733, sl no.1229.]]
Tender For purchase of chemicals - purchase of chemicals, diluent for dna extractionsize 500mla diluent used in dna extraction is typically te buffer (10 mm tris-hcl, 1 mm edta, ph ~8.0) or nuclease-free water, used to dissolve and dilute extracted dna. tris maintains a stable ph, while edta chelates divalent cations (e.g., mg ), thereby inhibiting dnase activity and protecting dna from degradation. the diluent must be sterile and free of nucleases to ensure the integrity of dna for downstream applications such as pcr, sequencing, and cloning., luria bertani mediumsize 500gluria bertani medium is a nutrient-rich growth medium commonly used for culturing bacteria such as escherichia coli and agrobacterium tumefaciens. it contains tryptone (10 g/l), yeast extract (5 g/l), and sodium chloride (10 g/l), which provide essential nutrients, vitamins, and osmotic balance for bacterial growth. lb medium supports rapid cell growth and is widely used in molecular biology for cloning, plasmid propagation, and transformation experiments. for solid media, agar (15g/l) is added., chloroform (high analytical reagent grade) size 2.5lchloroform (high analytical reagent grade) is a high-purity organic solvent used in dna extraction, particularly in phenol chloroform methods, to separate proteins and other contaminants from nucleic acids. it enhances phase separation by forming a distinct organic layer, allowing dna to remain in the aqueous phase. due to its toxicity and volatility, it must be handled under a fume hood with proper safety precautions., depcsize 25mldepc is a chemical used to inactivate rnases in water and laboratory solutions, making them suitable for rna work. it modifies histidine residues in proteins, thereby deactivating rnase enzymes that can degrade rna. depc-treated solutions are typically incubated and then autoclaved to remove residual depc, ensuring they are safe for use in downstream applications such as rna extraction and cdna synthesis., tb green master mixsize 200rnxtb green master mix is a ready-to-use reagent used in real-time pcr (qpcr) for dna amplification and detection. it contains tb green dye (a double-stranded dna-binding fluorescent dye), dna polymerase, dntps, mg , and reaction buffer. the dye binds to amplified double-stranded dna and emits fluorescence, allowing real-time monitoring of pcr amplification. it is commonly used for gene expression analysis and quantification of dna., dna loading dyesize 10 inchdna loading dye is a solution added to dna samples before agarose gel electrophoresis. it contains tracking dyes (such as bromophenol blue and xylene cyanol) that allow monitoring of dna migration during the run, and a dense agent (such as glycerol or sucrose) that helps the sample sink into the wells. it may also include edta to protect dna from nuclease degradation., metaloopa metal loop is a reusable laboratory tool made of platinum or nichrome wire, used for transferring and inoculating microorganisms onto culture media. it is sterilized by heating in a flame until red hot before and after use to prevent contamination. it is commonly used in microbiology for streaking plates and handling bacterialcultures.
Tender For supply of chrome uti agar plate. spec: 1. it should be ready made solid culture media in 90 mm disposable petri plate used for bacterialculture with minimum 4 mm thickness. 2. should be suitable for isolation and enumeration of bacteria from clinical specimens. 3. media should contain selective ingredients for inhibiting swarming of proteus and isolation of major uropathogens- gnb and gpc both. 4. manufacturer firm should have iso/bis+who gmp/european ce/fda/any recognised international council approval certification. 5. media should have a minimum shelf life of 3 months. 6. biomedical waste generated from the plastic petri plate should not generate carcinogenic byproducts on incineration/autoclaving/microwaving. 7. performance should be demonstrated to the satisfaction of end user with each new batch supplied. 8. it demonstrates good batch-to-batch reproducibility.( pack of 50 plates)[ai(2025-26) , item code no.s-60733, sl no.1229. ]
Tender For corrigendum : supply and installation of medical laboratory equipments on cost per test (cpt) basis to biochemistry, pathology andmicrobiology at central laboratory - third party controls for integrated bio chemistry and immunoassay machine kmio kmio, controls for cbc kmio, third party controls for cbc kmio, calibrator of integrated bio chemistry and immunoassay machine, controls for integrated bio chemistry and immunoassay machine kmio, third party controls for integrated bio chemistry and immunoassay machine kmio, calibrator for coagulation analyzer kmio, controls for coagulation analyzer kmio, automated slide with smear, any new tests should be added(in action column), complete urine analysis kmio, drug sensitivity test for cerebrospinal fluid (csf) / all body fluids (blood/urine/ascites/pleural fluids/pus /sputum, etc) kmio, automated blood culture and sensitivity kmio, urine routine- ph, specific gravity, sugar, protein and microscopy kmio, ckmb kmio, troponin i kmio, vitamin b12 kmio, pro bnp kmio, s protein electrophoresis (spep) kmio, urine immunofixation kmio, urinary protein electrophoresis (upep) kmio, igm kmio, igg kmio, iga kmio, s immunoglobulins kmio, he4 kmio, ferritin kmio, nse kmio, ca 15.3 kmio, ca 19.9 kmio, free t4 kmio, free t3 kmio, anti tpo kmio, ant-thyroglobulin (anti tg) kmio, thyroglobulin (tg) kmio, t3/t4/tsh kmio, tsh kmio, t4 kmio, t3 kmio, beta hcg kmio, psa kmio, ca 125 kmio, afp kmio, cea kmio, folic acid kmio, vitamin-d kmio, s galactomannan kmio, s methothrexate kmio, b-2 microglobulin kmio, s free light chains kmio, urinary vma kmio, s lipase kmio, a amylase kmio, s magnesium kmio, serum phosphorus kmio, fluid analysis (sugar protein) kmio, creatinine clearance (2 hrs) kmio, rft (urea creatinine) kmio, glucose tolerance test (gtt) kmio, lipid profile. (total cholesterol, ldl, hdl, triglycerides) kmio, calcium kmio, c reactive protein (crp) quantitative kmio, electrolytes (na/k/cl) kmio, lactate dehydrogenase (ldh) kmio, liver function test (lft) (sgot,sgpt,alp, total protein, albumin, globulin, ag ratio, direct,indirect & total bilirubin) kmio, uric acid kmio, creatinine kmio, urea nitrogen (bun) kmio, glucose random kmio, glucose pp kmio, glucose fasting kmio, serology (by chemiluminescence method)hcv antibodies, serology (by chemiluminescence method)hbsag, serology (by chemiluminescence method)hiv antibodies, mycobacteria (afb) smear/culture examination fluids kmio, mycobacteria (afb) smear/culture examination urine kmio, mycobacteria (afb) smear/culture examination pus kmio, mycobacteria (afb) smear/culture examination sputum kmio, fungal culture fluids kmio, fungal culture pus kmio, fungal culture stool kmio, fungal culture urine kmio, fungal culture ent (ear/nose/throat) kmio, fungal culture sputum kmio, bacterialculture & sensitivity fluids kmio, bacterialculture & sensitivity pus kmio, bacterialculture & sensitivity stool kmio, bacterialculture & sensitivity urine kmio, any other, bacterialculture & sensitivity ent (ear/nose/throat) kmio, consumables for fully automated coagulometer, consumables for fully automated identification and sensitivity system with mic values with amr surveillance assistance software, consumables for fully automated blood culture system, consumables for fully automated 5 part cell counter with retic and slide processor, consumables for fully automated integrated chemistry and immunoassay analyzer, third party controls for coagulation analyzer kmio, controls for microbiology machines kmio, controls for maicrobiology machines kmio, third party controls for microbiology machines kmio, controls for integrated bio chemistry and immunoassay machine kmio kmio, bacterialculture & sensitivity sputum kmio, d-dimer kmio, fibrinogen. kmio, thrombin time (tt) kmio, activated partial thromboplastin time (aptt), prothrombin time (pt)/ international normalized ratio (inr) kmio, erythrocyte sedimentation rate (esr) kmio, peripheral smear kmi
Tender For supply of chrome uti agar plate. spec: 1. it should be ready made solid culture media in 90 mm disposable petri plate used for bacterialculture with minimum 4 mm thickness. 2. should be suitable for isolation and enumeration of bacteria from clinical specimens. 3. media should contain selective ingredients for inhibiting swarming of proteus and isolation of major uropathogens- gnb and gpc both. 4. manufacturer firm should have iso/bis+who gmp/european ce/fda/any recognised international council approval certification. 5. media should have a minimum shelf life of 3 months. 6. biomedical waste generated from the plastic petri plate should not generate carcinogenic byproducts on incineration/autoclaving/microwaving. 7. performance should be demonstrated to the satisfaction of end user with each new batch supplied. 8. it demonstrates good batch-to-batch reproducibility.( pack of 50 plates)[ai(2025-26) , item code no.s-60733, sl no.1229. ]