Web Analytics Made Easy - StatCounter

Bacteriological Analyzer Tenders

Get complete information related to latest Bacteriological Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bacteriological Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bacteriological Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Co-operative

CTN :40969595 Due date: 19 Jul, 202519 Jul, 2025 NA
Tender For supply and installation and commissioning of spm analyzer - supply, installtion & commossioning of spm analyzer with tuv. as per specifications, the system should have the below features as desired by cpcb.a) the spm analyzer should have continuous quality check for zero and spa point, prferably without human intervention to ensure continuous daya validity and credibility. (please refer guidelines for continuous emission monitoring system july 2017 page 8/100)b) the system should have feature of automatic range setup.c) the system does not required manual adjustment and should operate without any human intervention.d) the system should have autotic drift compensation.e) the system doen not have optical windows to be cleaned.f) the system should not required any alignment for smooth operation.g) the system doen not have any effect of vibrations on the system accuracy and readings.h) the system should have tuv with qal (en15267 parts 1 to 3) with appropriate certification range as per cpcb guidelines.measurement principle: inductive electrificationmeasurement objects: solid particles in a gas flowparticle size : 0.3 um or largermeasurement range: approx 0.1 mg/m3 to 1 kg/m3probe length: as per requirement (standard 500,750,1000,1500,2000 mm)probe dia: 10 mm, max temperature: upto 300 degree c. (optional upto 700 degre c)max pressure: 3 bargas velocity: min 4 m/sresponse time: less than 1 secondself zero span check: yessignal averaging: adjustable 0-300 seondoutput signals: isolated 4-20 ma serial communicaiton rs-485 modbus - two spdt relays:5a-24 vac/dcambient temperature: 20 to +60 degree chumidity: 95% rh (non- condensing)vibration: 5 m/s2 or lessprobe: ss316 linsulation of probe: peekenclosure: aluminmb alloypower supply: 230 vac, 15 vac, 24 vdcpower consumption: 3 wprotection: ip65certification: tuv with qal1, chief engineer

Central Government/Public Sector

CTN :40937464 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For supply of vibration data collector cum analyzer

Central Government/Public Sector

CTN :40913524 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For supply of vibration analyzer with advanced diagnostic software

CTN :40890671 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For supply, installation and commissioning of line laser alignment kit & vibration analyzer kit required for 80 mw capacity hydro generator turbine set of ukhep, bariniput, dist: koraput, odisha

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso
 Loading, Please wait...

Connect us via What's Up