Get complete information related to latest Bagpipe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bagpipe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bagpipe Tenders.
Tender For corrigendum : supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentation cable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount
Tender For bid to ras supply of led screen for left and right side , adjustable left right tilting wall mount stand , indoor active led screen , digital podium with front signage screen , 20x optical zoom ptz camera , 30x optical zoom fhd ptz camera , camera controller , av bridge , recording and streaming device , wireless presenter system with handheld microphone , wireless headset system with headset microphone , antenna splitter and power distribution system , passive wide band uhf omnidirectional antenna , wired gooseneck microphone , digital signal processor with control processor , hdmi to usb 3.0 capture card , transmitter and receiver , hdmi matrix switcher , wireless touch controller , wireless access point , network switch , all required cable connectors lot for complete integration of all audio visual equipment , supply, installation, commissioning and testing of all items mentioned above
Tender For corrigendum : rfp for selection of an agency for providing on-site comprehensive annual maintenance contract services for ict equipment supplied under the coding and robotics education in schools (cares) scheme in the state of goa on an as is, where is basis - single board computing device (technical specifications: intel x64 processor 64-bit j4105 upto 1.5 ghz, 4mb cache with intel integrated graphics 600memory: 8gb ddr4 2666 mhz ramstorage: 64gb m.2 ssd,connectivity : realtek dual band (ax card) ac 1200 with bluetooth 5.1 mini pciex card, realtek 1 gbps ethernet porti/o: hdmi (upto 4k @ 100hz), 2 x usb 3.0 ports, 4 x usb 2.0 ports, vga port, combo audio jack,100 keys or higher usb keyboard,keyboard type: standard keyboard,lcd monitor:screen size: 19 inch,video conferencing camera,headphone with mic)(1st year cost), single board computing device (technical specifications: intel x64 processor 64-bit j4105 upto 1.5 ghz, 4mb cache with intel integrated graphics 600memory: 8gb ddr4 2666 mhz ramstorage: 64gb m.2 ssd,connectivity : realtek dual band (ax card) ac 1200 with bluetooth 5.1 mini pciex card, realtek 1 gbps ethernet porti/o: hdmi (upto 4k @ 100hz), 2 x usb 3.0 ports, 4 x usb 2.0 ports, vga port, combo audio jack,100 keys or higher usb keyboard,keyboard type: standard keyboard,lcd monitor:screen size: 19 inch,video conferencing camera,headphone with mic)( 2nd year cost), single board computing device (technical specifications: intel x64 processor 64-bit j4105 upto 1.5 ghz, 4mb cache with intel integrated graphics 600memory: 8gb ddr4 2666 mhz ramstorage: 64gb m.2 ssd,connectivity : realtek dual band (ax card) ac 1200 with bluetooth 5.1 mini pciex card, realtek 1 gbps ethernet porti/o: hdmi (upto 4k @ 100hz), 2 x usb 3.0 ports, 4 x usb 2.0 ports, vga port, combo audio jack,100 keys or higher usb keyboard,keyboard type: standard keyboard,lcd monitor:screen size: 19 inch,video conferencing camera,headphone with mic)( 3rd year cost), wifi based router (standard: ieee802.11/a/b/g/n/ac,interface: wan gigabit port, minimum 4 lan gigabit ports.antenna: minimum 4 external omni directional antennas.,data rate: upto 867 mbps (ac 1200),power adapter: ac input: 100-240 v 50hz to dc adapter)(1st year cost), wifi based router (standard: ieee802.11/a/b/g/n/ac,interface: wan gigabit port, minimum 4 lan gigabit ports.antenna: minimum 4 external omni directional antennas.,data rate: upto 867 mbps (ac 1200),power adapter: ac input: 100-240 v 50hz to dc adapter)(2nd year cost), wifi based router (standard: ieee802.11/a/b/g/n/ac,interface: wan gigabit port, minimum 4 lan gigabit ports.antenna: minimum 4 external omni directional antennas.,data rate: upto 867 mbps (ac 1200),power adapter: ac input: 100-240 v 50hz to dc adapter)(3rd year cost)
Tender For supply, installation, testing and commissioning of dcus/gateways/ allocation of sim network service provider and the arrangement of sim cards to enable reliable medium for two-way communication between smart meter & amp:, hes (head end system) over rf mesh network/cellular network. 1. the dcu/gateway shall be compatible with the smart meters mentioned above. rf mesh network should use 865-867 mhz frequency band. 2. the data acquisition (push/pull) frequency shall be configurable 15 min, 30 min or 60 minutes. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. 3. it shall have provision for the cellular, wifi and ethernet communication for the backhaul tohes. 4. sufficient number of gateways shall be installed in such a way that all the meters are covered in the network efficiently. 5. it shall be capable to handle data of minimum 500 nos. of any type of smart meter (1ph/3ph). it shall be able to communicate with the nearest meters at a distance of at least 300 m, depending on topographical features. 6. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. 7. rfmesh shall support at least 15 no. of hops. 8. the equipment shall be weather-proof and dust-proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. 9. it shall have passed the following emc tests from reputed lab: conducted emission, electrostatic discharge (esd), radiated immunity, electrical fast transient (eft) - burst, surge, rf conducted disturbances. 10. rf mesh network shall be established to meet the slas as mentioned in tender document. 11. replacement warranty period shall be 66 (sixty-six) months from the date of supply or 60 (sixty) months from the date of commissioning, whichever is earlier. [ warranty period: 30 months after the date of delivery ] ]