Get complete information related to latest Balance Beam Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Balance Beam Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Balance Beam Tenders.
Tender For supply of supply of 3 core 2.5 sqmm, fr lsh pvc insulated industrial grade copper conductor flexible cables, 1100 volts conforming to is 694. , supply of 4 core 4 sqmm, fr lsh pvc insulated industrial grade copper conductor flexible cables, 1100 volts conforming to is 694. , supply of 4 core 10 sqmm, fr lsh pvc insulated industrial grade copper conductor flexible cables, 1100 volts conforming to is 694. , supply of 3 to 3.5 mtr telescopic boom arm suitable for time watch boom barrier , supply of 400mm sweep pedestal fan with plastic body and blades, height adjustable with standard accessories suitable for operation on 230v, single phase ac supply etc., as required , supply of 400mm sweep wall fan with plastic body, mounting arrangement with standard accessories suitable for operation on 230v,single phase ac supply etc., as required. , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 6 a to 32 a sp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 20 a dp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 20 a tp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 40 a fp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 63 a fp mcb , supply of 40 a, double pole, residual current circuit breaker rccb, having a sensitivity current 100 ma suitable for operation on 230 v, single phase ac supply etc. as required. , supply of 63 a, four pole, 415 volts, residual current circuit breaker rccb, having a sensitivity current 300 ma suitable for operation on 415 v, single phase ac supply etc. as required. , supply of iro pro uo r relay c and s make.under voltage over voltage relay. , supply of four pole, contactor with ac 1 rating 40a and 230v ac coil voltage , supply of 2no plus 2nc 10a, contactor with 24v dc coil. , supply of 2no contractor with 24 v dc coil. make schneider model a9c20132 or equivalent , supply of 2mp dome camera suitable for existing cctv system. make honeywell, part no impact i hee2pl lp , supply of 2mp bullet camera suitable for existing cctv system. make honeywell, part no impact i hibb2pi lp , supply of media converter suitable for existing cctv system. make tricom , supply of poe switch 8 port suitable for existing cctv system. make dlink. , supply of sim based gsm autodialer along with 24v 2amp smps suitable for existing fire alarm system including . make pinnacle.
Tender For corrigendum : supply of 20 pairs x 0.5 mm. dia. copper conductor twisted pair armoured underground telecom pijf cable, with solid polythene insulated copper conductors, core fully filled with filling compound and with poly al laminate moisture barrier bonded to the polythene sheath as per tec generic requirements no. gr/cug-01/03aug 2003 with latest amendment / version / revision. [ warranty period: 30 months after the date ofdelivery ] ]
Tender For corrigendum : supply of zip line , activity board , balancebeam , pathways , therapy ball , therapy ball - spike , led chain , blue led , wedge , bolster , adjustable multipurpose bed table
Tender For supply of 20 pairs x 0.5 mm. dia. copper conductor twisted pair armoured underground telecom pijf cable, with solid polythene insulated copper conductors, core fully filled with filling compound and with poly al laminate moisture barrier bonded to the polythene sheath as per tec generic requirements no. gr/cug-01/03aug 2003 with latest amendment / version / revision. [ warranty period: 30 months after the date ofdelivery ] ]
Tender For supply of polythene insulated polythene sheathed jelly filled (pijf) underground telephone cable with poly-aluminium moisture barrier and steel tape armoured copper conductor confirming to rdso specification no. irs:tc-41/97 amd.1 to 3 or latest .size-20 pair x 0.63mm dia [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of polythene insulated polythene sheathed jelly field (pijf) telephone underground cable 10 pairs 0.5mm dia with poly-moisture barrier tec gr.no.gr/cug-01/03 aug 2023 (tec standard tec 68090:2003) or latest accepted make: finolex, polycab, havells, national cables, delton cables or better. with 30 months warranty [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh