Get complete information related to latest Balloon Catheter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Balloon Catheter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Balloon Catheter Tenders.
Tender For corrigendum : t. e. no - gmscl/d-773 /rc/2025-26 (on rate contract basis) surgical item (57 item) - disposable hypodermic needle size: 22x1", 297700, stainless steel, with needle cap, single use, size: 23x1", disposable hypodermic needle size: 24x1", 380500, stainless steel, with needle cap, single use size:24 x 1.5", disposable syringe 10 ml (without needle), 2003800, sterile single use syringes as per, sterile hypodermic syringe for single use size:5 ml (without needle), 1733900, length: 100 cm diameter: 2non biolable catgut chromic needle :1/2 circle round body 45 mm heavy, absorbable surgical suture polyglactin 910 {synthetic}with needle 1 with 1/2cir rb 40 mm, 428400, stainless steel, with needle cap, single use, size: 26x0.5", disposable spinal needle 22g x 3 .5" inch, 35300, stainless steel, single use,size 25g x 3.5", disposable spinal needle 23 g x 3.5", 218100, length : 90cms. diameter :1 triclosan coated polyglactin 910 1/2 circle rb 30-40 mm, permeable non woven surgical synthetic adhesive tape (non sterile). size: 1.25 cms x 9.1 meter, 117600, non toxic. non pyrogenicclosed distal end coned withradio-opaque material foraccurate placementsoft, frosted and kinkresistant pvc tubing,sterile by eto ,color coded funnel end connector for easy identification of size., ryles tube(eto sterilized),size-10., 7600, non toxic. non pyrogenicclosed distal end coned withradio-opaque material foraccurate placementsoft, frosted and kinkresistant pvc tubing,sterile by eto ,color coded funnel end connector for easy identification of size, combined spinal/epidural mini pack and needle set containing 18 g epidural mini pack and 26 g lancet tip spinal, 269000, 1) double lumen central venous indwelling catheter : polyurethane radio opaque with a soft tip,size- 7 f: 16 g/16 g. length 15 cm, 20 cm 2) introducer needle:y needle with check valve to provide a second port 3) guide wire :j- tip, kink resistance, soft tip, resilient, with length markings 4) scalpel5) dilator 6) catheter holder for fixation 7)fully transparent extension line with colour coded hub with white slide clamp, air tight closure at injection port 8)injection cap 9) must have sterile dressing, pigtail catheter with needle size -14 f, 54700, iso 13485 as amended from time to timepigtail catheter set for dranage.size of needle-:16 f with guide wire diameter of 0.046".length-:35-40 cm appox,cathater material-:tpu.troccar needle-:stainness steel.trocar stylet-:stainness steel. cathater introduction stiffening canula -1,multihole drainage cathater-1., insulin syringes - 40 iu, 241100, haemostatic sponge in surgical procedure pharma grade, pure gelatin size-8x3 cm, monofilament polyamide black (non absorbable) 38 mm ,10/0 (0.2 metric), sterilized surgical needle suture ,with needle suture, with two needles (double arm) spatulated 6 mm, 3/8 circle needle, 38300, polyglactin 910- 4 inch/10 cm ,10/0(0.2 metric),sterilized surgical needle suture, with needle spatulated 6 mm,3/8 circle needle, double lumen central venous cathater size : 9 f 13 g/13 g length 15 cm 20 cm, 192200, iso 13485 as amended from time to time tube size : 28 fr bag capacity : 2000 ml specially designed kit for post-operative abdominal drainage consists of super smooth rainage catheter along with a collection bag.made from non-toxic and non- irritant medical grade pvc.provided with specialised foldable handle which holds the tube upright prevents accidental kinking during handling & suitable for bedside hanging.soft & smooth catheter with large atraumatic eyes for efficient drainage.radio-opaque line throughout catheter length help x-ray visualization.catheter is color coded for instant size identification.sterile individually packed in peelable pouch.unit consists of : soft drainage catheter 50 cm long collection bag of 2000 ml capacity. transparent with volume measurement marking., pvc abdominal drain kit no 32 fr, 61700, iso 13485 as amended from time to time10 x 10 cm collagen sheet should be 100 per
Tender For corrigendum : supply of drug and pharmaceutical items - ecfa 20 tab dabigatran etexilate 150mg , ecfa 20 ankle strap sizelarge , ecfa 20 ankle strap sizemedium , ecfa 20 ankle wrap l , ecfa 20 band aid strips antiseptic washproof , ecfa 20 bandage open woven uncompressed 10 cm x 4 metres , ecfa 20 bandage open wovencompressed 2dot5 cm x 4 metres , ecfa 20 baseball finger splint , ecfa 20 cannula iv with injection port and wings size 16g , ecfa 20 cannula iv with injection port and wings size 18 g , ecfa 20 cannula iv with injection port and wings size 20g , ecfa 20 cannula iv with injection port and wings size 22g , ecfa 20 cotton wool nonabsorbent pkt of 500 gm , ecfa 20 dressing medicated adhesive 25 cm x 6 cm in a single strip pack , ecfa 20 dressing medicated gauze paraffin 10 cm x10 cm tin of 24 , ecfa 20 dressing sterile adhesive 5 x 7dot2 cm , ecfa 20 dvt stocking large l thigh high , ecfa 20 dvt stocking medium m thigh high , ecfa 20 elbow support , ecfa 20 foleys ballooncatheter 2 way silicon 20g , ecfa 20 foleys ballooncatheter 2 way silicon 22g , ecfa 20 finger cot splint , ecfa 20 frog finger splint , ecfa 20 gauze absorbent folded 2dot5 cm x 100 metres , ecfa 20 gauze surgical open woven unmedicated 60 cm wide , ecfa 20 hernia belt size l , ecfa 20 iv set micro , ecfa 20 non absorbable surgical suture mersilk 30 25mm rb 1 2 circle , ecfa 20 rib support belt , ecfa 20 silver sulfadiazine 1prcntge ointment 500 gms jar ) /bid number : gem/2025/b/6897499 * /dated: 15-11-2025 & & / bid document 1 / 29
Tender For supply of pcnl drape set , turp drape set , cystoscopy drape set , turp irrigation set , guide wire with nitinol core hydrophilic coating 3cm flexible straight 0 point 035 inch 150cm , guide wire with nitinol core hydrophilic coating 3cm flexible angled 0 point 035 inch 150cm , zebra guide wire straight 0 point 035 inch 145cm , double j stent open end 5fr 26cm , double j stent open end 6 fr 26cm , foleys catheter 2 way 14fr , foleys ballooncatheter 3 way 18fr , foleys ballooncatheter 20fr 3 way , 100 percent silicon foleys catheter 14 fr
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cms (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 20 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014., suction catheter, sterile. size: fg 22 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye. colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley ballooncatheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloonballoon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley ballooncatheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloonballoon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as p