Web Analytics Made Easy - StatCounter

Batching Plant Tenders

Get complete information related to latest Batching Plant Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Batching Plant Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Batching Plant Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40563358 Due date: 05 Jun, 202505 Jun, 2025 7.15 Crore
Tender For state scheme(nabard)/25-26/kishanganj-2/01 - construction of rcc h.l. bridge in malgachh to lat at ch.-0.600 km., h.l. bridge work, foundation, excavation for structures, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification., pile cap in rcc m-30 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load, a) initial load test on test pile for 2.5 times the design load specified in drawings, 1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specification, i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), r.c.c. grade m-35 in substructure complete as per dwg & tech specification, ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8, i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5, ii. rcc m-30 (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical sp

CTN :40563360 Due date: 05 Jun, 202505 Jun, 2025 8.02 Crore
Tender For state scheme(nabard)/25-26/kishanganj-2/02 - construction of rcc h.l. bridge in t05 to raipur to jharkhuda path (mmgsy) ch-0.030 km, h.l. bridge work, foundation, excavation for structures, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification., pile cap in rcc m-30 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth, providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth, carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load, a) initial load test on test pile for 2.5 times the design load specified in drawings, 1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specification, i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), r.c.c. grade m-35 in substructure complete as per dwg & tech specification, ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8, i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinfo
 Loading, Please wait...

Connect us via What's Up