Web Analytics Made Easy - StatCounter

Battery Cell Tester Tenders

Get complete information related to latest Battery Cell Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Battery Cell Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Battery Cell Tester Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45596388 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For supply, installation, testing and commissioning of electrical and mechanical equipments for shallow bore tube wells phatak bans,sawar khan, chatta mom gran, lal darwaza in matia mahal constituency ac-21. - s/o submersible pump set fitted with dynamically balanced ep impeller mounted on stainless steel shaft protection sleeve ep stage bowl of closed grained shorted type impeller. the pump will be directly coupled to required wet type induction motor of speed 2900 rpm suitable for operation on three phase ac, 415 volts ,50hz, 5 hp, model no j46, head-70 mtrs, discharge-200 lpm. make:bs/ksb/crompton/djb approved, supply of automatic lt panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for operation of up to 15 hp submersible set, made out of not less than 2 mm thick crca for load bearing members and 1.6 mm for doors of panel, totally enclosed, dust and vermin proof, floor mounted type. the panel size 760 mmx 1360 mm x300 mm and having (1) 63 amp change over- 1 no (2) 63 a tpn mccb -1 no (3) amp meter 0-50 a- 1 no (4) voltmeter 1 no (5) amp & volt meter selector switches-1 set (6) auto-manual + light + control mcb tp 32 amp- 1nos each (7) ct -3nos (8) push button + on/off light 2 nos each (9) 5 kvar shunt capacitor- 1 no (10) aluminium bus bar size 25 mm x 6 mm - 1set (11) 15 hp star delta starter (a) 32 amp power contactor-3 nos (b) overload relay 14-23 a -1 no (c) star delta timer- 1 no ( d) qt timer -24 hours -1 no (e) motor protection relay 200 short circuit, earth fault, phase loss, unbalance, phase reversal, locked rotor protection make:-subtec/protech/ l&t/all djb approved make, s/o pvc insulated flat submersible cable with copper conductor having three core size 2.5 sq mm 1100 volts(100mtr per roll). make- gloster/universal/havells/grandlay/djb approved, s/o g.i pipe 40mm dia medium class with threaded externally on both end socketed 6mtr long. make- jindal/tata., s/o g.i tail piece 40mm dia 600mm long medium class with threaded externally on both end. make- tata/jindal, s/o gi socket 40 mm dia with threaded internally. make: jindal/tata/djb approved, s/o gi elbow with both end having thread, size- 40mm. make: jindal/tata/djb approved, s/o gi reducer having thread on boyh end, size: 50mm to 40mm. make: jindal/tata/djb approved, s/o gi union having thread on both end, size: 40mm. make: jindal/tata/djb approved, s/o ms clamp of 600mm long 12mm thick complete with nut & bolts and washers for holding 40 mm dia pipe i/c bending & shaping etc., supply of ms bore cover 6 mm thick suitable for 100 mm dia casing in 2 pieces complete with bolting arrangement angle iron frame and provision of 40 mm dia hole in the center., supply of pvc suction hose pipe 50 mm dia 30 mtr long.make-jyoti/isi, installation of submersible pump set with pipe and other accessories, connection of cable, installation of electric panel, grouting of electric panel digging and fixing the same with the help of cc and laying of gi pipe from bore to panel executing minor civil making electrical connection with cable as required size i/c watch and ward cartage, taking all safety measures all tools and tackles. testing and commissioning of all e&m equipment on no load and full load conditions as per standard and full satisfaction of engineer-in- charge. this is a turnkey job and it further includes any left out items which may be required during execution of work will be firm responsibility & no extra payment will be paid. - s/o submersible pump set fitted with dynamically balanced ep impeller mounted on stainless steel shaft protection sleeve ep stage bowl of closed grained shorted type impeller. the pump will be directly coupled to required wet type induction motor of speed 2900 rpm suitable for operation on three phase ac, 415 volts ,50hz, 5 hp, model no j46, head-70 mtrs, discharge-200 lpm. make:bs/ksb/crompton/djb approved, supply of automatic lt panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for opera

State Government

CTN :45591291 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For quotations for calibration of various equipments of regional meter testing laboratory-single phase meter test system/ld 13086 ,three phase refrence standard/050088433 ,multi secondary voltage transform er/025022608

Co-operative

CTN :45571694 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For inspection, testing, measurement and rectification/improvement of earthing system covering lifts, meter rooms and all society wings, including submission of technical recommendations and allied works

Central Government/Public Sector

CTN :45329483 Due date: 24 Jun, 202624 Jun, 2026 12.61 Lacs
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu

CTN :45581741 Due date: 01 Jul, 202601 Jul, 2026 3.63 Lacs
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c

Corporations And Associations And Others

CTN :45523190 Due date: 19 Jun, 202619 Jun, 2026 4.76 Lacs
Tender For provision of new led street lights with allied accessories on existing poles at various dark spots in saidulajab ward no 160 under south zone - led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy >135 lm/watt). supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd 10% as per iec 61000-3-2, p. f. 0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitary) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation color matching)5, maximum power consumption should not more than the specified rating and fixture shallbe of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductorsingle core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 testreport and all testing required for led fixturesas per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge asper requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). 45 watt , supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm

Corporations And Associations And Others

CTN :45523194 Due date: 19 Jun, 202619 Jun, 2026 4.67 Lacs
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt

CTN :45562952 Due date: 01 Jul, 202601 Jul, 2026 43.22 Lacs
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine & power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura for the project "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department” under the nec scheme. (2nd call) - supplying, installation, testing and commissioning of electrical measurement, electrical workshop, electrical machine & power system laboratory equipments/machineries of electrical engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department." (2nd call), kelvin double bridge trainer kitthe instrument should have following features : easy illustration of kelvins bridge digital display (dpm) for null detection online product tutorialthe instrument should have following technical specifications :dc power supply : +5vknown resistance : r1=100k , 20k , 10k r3=1k , 200 , 100 dpm : 2vdimensions (mm) : 240 w x 345 d x 110 hunknown resistance : 0.3 , 0.4 , 0.8 mains supply : 230 v 10%, 50 hz, whetstone bridge trainer kitthe instrument should have following features :sample : constantan, nichromeprovided with dc power supply compact designeasy to operatethe instrument should have following technical specifications:dc power supply:5vgalvanometerdeflection:30 - 0 30resistance:80 unknown resistance type: variablerange:0 - 10k wire samples: -constantan: 1mnichrome:1mfuse:500mamains supply: 90 - 275v, 50hzdimensions (mm):w 345 x d 240 x h 110, experimentation with de sautys and schearing bridgethe instrument should have following features: - a complete set up with all necessary accessories inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmtechnical specification: -sine wave generatorfrequency range:1khz 10%amplitude control output: up to 15vppfuse:500 ma, s/bdpm:200 mvunknown capacitor:0.1 f, 0.22 f, 0.47 fmains supply:230v ac, 10%, 50hzdimension (mm):w 345 x d 240 x h 110, experimentation with maxwells bridgethe instrument should have following features : illustration of both maxwells inductance bridge and maxwells inductance-capacitance bridge on a single board inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmthe instrument should have following technical specifications :mains supply : 230 v 10%, 50 hzdc power supply : +12v, -12vsine wave generatorfixed frequency : 1khz 5%amplitude control range : upto 20vppunknown inductors : 10 mh, 20mh, 30 mh, 56 h, 24 h, 12 hdpm : 200mvunknown internal resistance : 470w, 10 , 20 , 30dimensions (mm) : w 240 x d 345 x h 110, measurement of three phase active & reactive power with single phase wattmeter technical specifications:analog meters: analog voltmeter, range : 300v analog ammeter, range : 2a analog wattmeter power supplies: operated on mains power 415v, 50hz +10%components are mounted on the panels are: capacitive load inbuilt inductive load inbuilt resistive load (external)salient features: three phase power light indicator for mains. front panel built with high class insulated bakelite sheet with sticker well printed circuits and symbols. mcb for short circuit protection connections are brought out through 4mm colored safety sockets. patch cords 4mm. the trainer is housed in metal cabinet. size of the trainer set 36 x 24 , power & power factor measurement by ct & pt in three phase circuittechnical specifications:power supplies: ac power supply 0-415v at 4a operated on mains power 415v, 50hz +10%digital meters: digital voltmeter digital ammeter , digital wattmeter (analog), digital power factor meter components are mounted on the panels are: 3 phase capacitive load (inbuilt) 3phase resistive load (external) 3phase inductive load (external) emergency stop

Central Government/Public Sector

CTN :45527554 Due date: 30 Jun, 202630 Jun, 2026 78.90 Lacs
Tender For tender for supply of sitc of walkie talkie system at mvi airport ayodhya dham - supply , installation , testing and commissioning of vhf handheld walkie talkie as per attached technical specifications . , supply , installation , testing and commissioning of vhf vehicle mounted base station including all standard accessories with spring whip /gp antenna , minimum 3 meter lmr 240/rf cable etc. complete as required as per attached technical specifications . , supply , installation , testing and commissioning of fixed base station including all standard accessories with spring whip /gp antenna , minimum 30 meter lmr 240/rf cable etc. complete as required as per attached technical specifications . , supply of handsfree kit of walkie talkie handheld sets as per attached technical specifications . , supplying of 2 pair 0.5 mm dia frls/hffr pvc insulated annealed copper conductor , unarmored telephone cable complete as required

Central Government/Public Sector

CTN :45555774 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply, termination installation, testing and commissioning of ventilation system on roof of paint shop of lower parel workshop along with complete installation, frame work of suitable size with ms 50mmx 50 mmx 5mm, cabling, cable try work, wiring and protection system with 4 pole 20a mcb for each and mcb board along with 2.5 sqmm cable 4 core and 10 sqmm cable from panel to distribution board for main supply and power full exhaust system of length and height minimum 1 meter with width minimum 400 mm, diameter blades 900 mm, blades rotational speed -620 r/min or more. air flow 30,000 m?/h, noise level shall be less than 70 db, power shall be minimum 750 watt with the flap system and motor starter of 1 hp or as per suitable and confirming to s/iec 60947-4-1 or latest. all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up