Get complete information related to latest Battery Fuse Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Battery Fuse Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Battery Fuse Box Tenders.
Tender For supply of switch fuse unit (q3) , modular electrical enclosure switch board boxes for modular type accessories (q3) , xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2)
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c
Tender For supply of fuse fitting unit totally enclosed molded type to accomodate hrc cartridge fuse link 15a without cartridge fuse 415 volt s front connection type similiar to english electric type nsh.with isi mark. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of spares for afdss system of komatsu make wa 800 3e0 wheel loaders - nitrogen cylinder assembly, 0.5 lit, part no. - se57112 , control unit assy, part no. - se57110 , horn unit, part no. - se57392 , fuse 3a, part no. - se53557 , co2 cartridge - 300 gm, part no. - se53994 , nozzle conical, part no. - se53508 , elbow 1 by 2 inch, part no. - se535021 , refilling kit for automatic fire, part no. - se57330 , rupture disc assy - dcp cylinder, part no. - se54686 , dcp cylinder - 20kg, part no. - se57510
Tender For corrigendum : supply of 21 point 8kv 130 point 9kvar 1phase 50hz fuse less capacitor units type bcc1 , 6 point 67kv 607point 38kvar 1phase 50hz internal fuse capacitor units type hp12 by 24a hv , 8 point 79kv 217 point 17kvar 1 phase 50 by 125 50hz internal fuse capacitor unit type hp3 hv , 9 point 75kv 191kvar 1 phase 50 by 125 50hz fuse less capacitor unit type plc1 , 9 point 75kv 38 point 2kvar 1 phase 50 by 125 50hz fuse less capacitor unit type plc2
Tender For supply of anti pumping relay 11 pin 110v ac, part no. 1901709 , rectifier bridge unit 60 or 63a 600piv 100v, part no. 1925362 , machanism motor wound spring charged 25k, part no. 1435279 , switch auxiliary assembly, part no. 2120276 , spring charging motor, part no. 1435530 , mechanism catch 25ka, part no. 1435292 , shunt trip coil 110 v dc, part no. 2064674 , vtc or closing coil 110 v dc, part no. 2064613 , fuse, ht,pt,11kv,5a , pt resin cast 3ph 5 limb 6.6kv or 110v or 63, part no. 2267718 , epoxy resin cast current transformer rat, part no. ba1132 , current transformer ctr 600 300 or 5, part no. ctr600300 , relay e or l 50a 1a 110v ac, part no. 1902284 , idmt relay, part no. p0083 , bus bar spout 1200 amp, part no. mv3308 , support insulator for fixed type vcb p00, part no. p0063 , 3.3kv or 6.6kv off load isolator assy upt, part no. 100030 , clamp, al,55mm,strght,busbr , switch, lmt,stopper,220v,10a,2no plus 2nc , padlocing, part no. pcvc3338 , switch control breaker pistol grip, part no. 2121074 , mvng contact, isltr,11kv,outdoor,630 or 800a , vcb 11 kv 1250a25kambl, part no. 418535