Get complete information related to latest Batton Holder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Batton Holder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Batton Holder Tenders.
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For supply of accessories for cable- (i)piercing connector type-i 16-50, (ii)piercing connector type-ii 16-50, (i)piercing connector type-i for single phase/ three phase (main 70-150 sqmm. tape of 50-95sqmm), (ii)piercing connector type-ii (main 70-150 sqmm tape-of 50-95 sqmm), suspension clamp with attachment, tension clamp with attachment, cable straight-through joint kit suitable for 70 sqmm, cable end termination kit suitable for 70 sqmm, i)t clamp for bus bar for dog to dog conductor, ii)terminal clamp for busbar for panther conductor, bi-metallic clamps for vcb, bi-metallic clamps for transformer, 30v 100ah lead acid battery, battery charger suitable for 30 v 100ah battery, 30v dc lithium-ion battery set, lt robust fuse unit/switch fuse unit, gi pipe 150mm b grade, gi pipe 150mm a grade, heat shrinkable cable jointing kit with lugs for 33/11 kv 3 core (33/11kv, 3*300 sqmm), (i)ht bi-metallic clamps for dtr, (ii)lt bi-metallic clamps for dtr, (i) dc distribution board with mcb, (ii)ac distribution board with mcb, led lamp complete fitting, (i) aluminium lugs 70 sqmm, (ii) aluminium lugs 150 sqmm, (iii) aluminium lugs 300 sqmm, pf unit (kitkat) 200 amp., pf unit (kitkat) 300 amp., hrc fuse base 200/250 amp., hrc fuse base 300 amp., hrc fuse base 400 amp., hrc fuse link 200/250 amp., hrc fuse link 300 amp., hrc fuse link 400 amp, hand operated chain pulley block 3 ton, silica gel breather 500 gm., (i) bi-metallic clamp suitable for 12mm dia lt stud, (ii) bi-metallic clamp suitable for 20mm dia lt stud, (iii) bi-metallic clamp suitable for ht stud, i) i-bolt 20 mm., ii) i-bolt 16 mm., t.c. fuse wire 14,16,18 & 20 swg, ethical & generic medicines and surgical items for dispensary mppkvvcl, ujjain
Tender For corrigendum : supply of vhf sets with accessories for cisf d d -portable digital radio set, , vhf repeater with high gain antenna , vhf base station radio sets , 5by8 3 db gain omindirectional antenna , rf coaxial cable with connectors 30mtr , 12vdc power supply unit 10amps batt , six slot charger for dmr handheld radios , network switch 24 port , liasoning charges , itc and programming of vhf system