Web Analytics Made Easy - StatCounter

Beam Detector Tenders

Get complete information related to latest Beam Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Beam Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Beam Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41302754 Due date: 08 Aug, 202508 Aug, 2025 4.52 Lacs
Tender For replacement of beam detector in tagore theater in sector-18, u.t. chandigarh.

Central Government And Public Sector

CTN :41273203 Due date: 22 Aug, 202522 Aug, 2025 NA
Tender For supply of dual frequency, nortec-600 eddy current flaw detector

CTN :41251449 Due date: 13 Aug, 202513 Aug, 2025 NA
Tender For supply of repairing of security related equipment : : - ip bulllet camera 2 mp cctv , ip speed dome ptz 2 mp , wireless cctv resolution , hd 32 channel nvr , hd16 channel nvr , online ups 2 kva , alarm control panel , lcd keypad , quad beam detector 100m , 8 zone expander , ofc 12 core , media convertor single mode dual fibre giga , splice enclosure , liu 48 port , liu 24 port , camera mounting pole , power cable 2 core 1.5 sqm , power sup 12v 2a , switch 24 port giga , switch 16 port giga , 8 zone expander enclosure , cat 6 upt outdoor , pole 6 feet mounting sensor , 40 inches led tv , 32 inches led tv

Central Government/Public Sector

CTN :41280440 Due date: 01 Sep, 202501 Sep, 2025 NA
Tender For supply of high frequency digital axle counter multi section type complete system includ ing central evaluator (s), final track clearance relay for each track section, reset boxes, lv boxes, dete ction points, mushroom housing for track side electronic and all other accessories fully wired to the ulti mate capacity and fully equipped to the configuration specified as per rdso specification no. rdso /s pn / 176/2013 (ver. 3) and oem specification for 24 detection points and 14 track sections. length of i nbuilt cable with axle detector shall be 15 meters [ warranty period: 30 months after the date of del ivery ]

corporations/Associations/Others

CTN :41093755 Due date: 08 Aug, 202508 Aug, 2025 5.35 Lacs
Tender For supply of multimeter and other instrument - digital multimeter 6000 counts lcd display 3.5 digit with a pleasant white backlight. ac/ dc current range up to 20a. resistance, capacitance, diode & continuity measurement facility. selectable frequency & duty cycle measurement. highly linear readings. select, range, hold/light, rel, hz/duty. max/min function incorporated. safety ce, cat iv (600v), ip 54, en 61326-1 & iec 61010-1, robust, rugged & double mold casing. operating temperature : 0 c to 50 c , accuracyaccuracy is specified as (% of reading + digits), ac voltage accuracy (1% + 3), dc voltage accuracy (0.25% + 3), ac current accuracy (1.5% + 5), dc current accuracy (1.2% + 5), resistance accuracy up to 600 k (0.5% + 3), safety- directives for ce certification : lvd:2006/95/ec., emc: 2004/104/ec measurement category : cat iii, (1000v) reinforced insulation. relevant standard specification : en 61010-1:2010, en 61326-1:2006, ip rating (dust & water protection) : ip 54, overload protection, fuse protection for a & : 0.8 a/ 250v fast blow type ceramic fuse. ma input terminal, fuse protection for 10a : 20a/ 500v fast blow type ceramic fuse input terminal. / / / / /hz(%) : 440 v dc / ac rms., digital clamp meter model dcm details: measure current upto 300 a, voltage range (v) 500 mv to 1000 v, operating temperature ( c):-10 c to +50 c storage temperature ( c): -40 c to + 60 c safety ip rating iec 61010-1, digital multimete r 4.5 digit details: 1. digital multimeter 2. auto 3. manual 4. 1kv ac/dc 5. 10a ac/dc 6. true rms 7. 19999 count 8. 4.5 digit, hydogen leak detector details: sensor for hydrogen gas leak detector system: ceiling mounted type, sensing covering area: 3-4 meter in diameter, operating temp: 0 c to 55 c, accuracy: +/- 0.4 % of h2 for 4 % max h2, response time: 3 sec, power supply: 24 vdc, 80ma max, with all necess such as signal cable, fixing screw etc

CTN :40955282 Due date: 18 Aug, 202518 Aug, 2025 NA
Tender For item wise procurement and supply of laboratory items for a period of 12 months - equipments, digital turbidity meter/ nephelometer -(a).parameter range- 0 to 200 & 200 to 1000 ntu*. (b). readability - 0.1 ntu & 1.0 ntu. ( c). accuracy - 3% of range. (d). repeatability - 2% of range. (e). light source - tungsten halogen lamp. (f). detector - photo diode. (g). data presentation - 31/2 digit 7 segment led of 12.7 mm height. (h). accessories - matched test tubes- 5 nos. (i). useful for determination of sulphate, phosphate, chloride, zn, ag, etc. by astm procedure. (j). extendable for measurement of inhibition growth of semantic microbial agent .brands-systronic,techlab,elko, digital conductivity meter with conductivity cell type cc-03b. (a). conductivity range : 0 to 20,200 m s*, to 2,20 & 200 m s*, (b) readability : 0.05% of range, (c) accuracy ; +_1% of range, (d) repeatability;+_1% of range, (e) data presentation: 31/2 digit 7 segment led of 12.7 mm height, (f) operating frequency: 1000hz, (g) temp. compensation: 0 to 500 c manual, (h) cell constant: 0.05, 0.1 or 1.0 (selectable), (i) out put: 20mv full scale into 10kz resistive impedance, (j) accessories: cell stand with cell holding clip.brands-systronic,techlab,elko, digital ph meter with combined ph electrode type cl - 51b (a). ph range: 0 to 14, +_1999 emf (mv), (b) readability : 0.1 ph, 1emf(mv), (c) accuracy ; +_0.01 ph, +_1 emf (mv), (d) repeatability;+_0.01 ph, +_1 emf, (e) temp. compensation: 0 to 1000 c manual, (f) data presentation: 31/2 digit 7 segment led of 12.7 mm height with polarity, (g) accessories: stand with electrode holding clamp, buffer tablets and polythine bottle, (h) physical dimensions: size 295 x 165 x 140 & weight - approximate 3, (i) manual 2 point calibration for ph, digital salinity meter (micro processor based water analyzer with magnetic stirrer), (a) measures directly ph, emf, temperature, electrolyte conductivity(ec), total dissolved solid (tds), dissolve oxygen (do), sanitary colorimeter (abs & %t) and turbidity in water sample one at a time. (b) data presentation: 2 lines 16 character dot matrix lcd modules, (c) light weight portable and easy to carry on field, (d) operates on rechargeable battery & mains supply, (e) ph: range- 0-14, readability- 0.001, accuracy - +_0.001,repeatability - +_0.1, (f) emf (mv): range- +_1999,9, readability - 0.1, accuracy - +_0.1, repeatability- +_0.1, (g) temp: range - 0-1000 c, readability - +_0.1, accuracy - +_0.5, repeatability - +_0.1, (h) ec; : range - 0-200 ms (5 ranges), readability - 0.05% of range, accuracy - +_0.1 of range, repeatability - +_0.5% of range, (i) tds: range- 0 to 100 ppt 5 range with pds factor 0.5, readability - +_0.05% of range, accuracy - +_1% of range, repeatability - +_0.5% of range, (j) do: range - 0-20, readability - 0.1, accuracy - +_0.1, repeatability - +_0.1 (k) colorimeter: range- +_2 abs & 0 to 100% t, readability - 0.001, accuracy - +_0.05 abs, repeatability - +_0.01 abs, (l) turbidity: range - 0 to 100 ntu, readability - 0.001, accuracy - +_2%, repeatability - +_0.1% (m) salinity ranger: 0 to 40 ppt, accuracy - +_1%, temp, compensation - 0 to 500c, sensor- ise (chloride) & re- bnc, (n) accessories: ce, dip type conductivity cell of 1.0 cell constant, do probe, thermo probe, magnetic stirrer, mains operated electromagnetic stirrer gi 631, stirring capsules, electrode stand with holding clamp, gas permeable membranes and 10mm & 30mm test tubes., zerological water bath superior quality(manufactures specification should be uploaded), ph meter (pocket type), brands-tamp,techlab,scientix, tds meter (pocket type) ,brands-tamp,techlab,scientix, magnetic stirrer superior quality (manufactures specification should be uploaded), heating mantle superior quality (manufactures specification should be uploaded), rainguage with measuring cylinder superior quality (manufactures specification should be uploaded), water purifier (dew drops)superior quali

CTN :40785774 Due date: 21 Aug, 202521 Aug, 2025 NA
Tender For procurement of spares for mi-17v5 helicopter - overhaul manual of 17mt-7215-05, overhaul manual of 8mt-7102-10/apu, overhaul manual of 8mt-7202-10/rh & lh jn box/ohm, illustrated part catalogue of 8mt-7210-036/036-003/relay panel, overhaul manual of 8mt-7210-036/036-003/relay panel, overhaul manual of 8mt-7210-160/rh cb panel, illustrated part catalogue of 8mt-7210-20, overhaul manual of 8mt-7210-20, overhaul manual of 8mt-7210-230/rt console panel, overhaul manual of 8mt-7210-300/rt control panel, overhaul manual of 8mt-7210-340/central control panel, overhaul manual of 8mt-7210-440-003, overhaul manual of 8mt-7210-50/80sv/ lt & rt s/w panel, illustrated part catalogue of 8mt-7213-10/3, overhaul manual of 8mt-7213-10/3, illustrated part catalogue of acr-500 v/uhf txrx, overhaul manual of acr-500 v/uhf txrx, repair manual of acr-500 v/uhf txrx, illustrated part catalogue of d-20-2, overhaul manual of d-20-2, illustrated part catalogue of d-500tb, overhaul manual of d-500tb, illustrated part catalogue of epv-50 bt-2s, overhaul manual of epv-50 bt-2s, illustrated part catalogue of mfpu-8, maintenance manual mfpu-8, overhaul manual mfpu-8, repair manual mfpu-8, illustrated part catalogue of mp-100s-3s/ elect motor, overhaul manual mp-100s-3s/ elect motor, illustrated part catalogue of nat-301, repair manual nat-301, overhaul manual of pmk-21-3s, illustrated part catalogue of p-119-3f-125, overhaul manual of p-119-3f-125, ) illustrated part catalogue of p-507 cvr) illustrated part catalogue of p-507 c, overhaul manual of p-507 cvr, repair manual of p-507 cvr, illustrated part catalogue of pmk-21-3s, illustrated part catalogue of po-500a, overhaul manual po-500a, illustrated part catalogue of pt-125, overhaul manual of pt-125, overhaul manual of rio-3a/bis-4n, illustrated part catalogue of sgu-15, overhaul manual of sgu-15, repair manual of sgu-15, overhaul manual of so-121-vm, overhaul manual of sspfk-bi-2s, overhaul manual of ter-1m, illustrated part catalogue of tks/601 kod/dod, overhaul manual of tks/601 kod/dod, overhaul moverhaul manua of l20-09-989 sfsvanua of l20-09-989 sfsv, overhaul manual of 20-1009-813-10 feathing test sol valve, overhaul manual of 20-1009-953 ve-2t, overhaul manual of 20-1257-704/705, overhaul manual of 20-760-801-10 auto feather, overhaul manual of 682700-2pc reducer box, maintenance manual of akip-4501 distortion meter, operating manual of akip-4501 distortion meter, overhaul manual of at 8-3 auto transformer, overhaul manual of bchf-208 phase sequence unit, overhaul manual of di22a throttle, overhaul manual of f-100 filter, overhaul manual of f-70 filter, overhaul manual of k-50 condensor, overhaul manual koch-1a frequency cut off unit, overhaul manual of kul-150 control box, overhaul manual of kvps condensor, overhaul manual of mkt-4a electomagnet, overhaul manual of pul-1a control panel, overhaul manual of pus-36-71, overhaul manual of sbk cabin light, overhaul manual of ss-78 chip detector, overhaul manual of tf-1 current transformer, overhaul manual of tn 115/7.5 transformer, overhaul manual of tr 115/36 step down transformer, overhaul manual of tr-100 regulating transformer, overhaul manual of ts 1-2s transformer, overhaul manual of ts310s04b transformer, illustrated part catalogue of ark-9, repair manual of ark-9, illustrated part catalogue of ark-ud, circuit diagram of gr2.087.223-01ps, illustrated part catalogue of gr2.087.223-01ps, maintainance manual of gr2.087.223-01ps, circuit diagram of gr2.087.224-06, maintainance manual of gr2.087.224-06, illustrated part catalogue of ri-65, techincal description, ipc & repair manual of rv-3m, maintenance manual gui-301.034 rf.110.42.00 of rv-3m, oh manual of spu-, illustrated part catalogue of yadro-1a, oh manual of yadro-1a
 Loading, Please wait...

Connect us via What's Up