Get complete information related to latest Bearing Cover Outer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bearing Cover Outer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bearing Cover Outer Tenders.
Tender For tender for supply of procurement of rotork make mov spares - rotork k series actuator main pcb card , thrust bearing with washer , k1000f16e , power module , k rangeactuators , rotork , localremote knob , k rangeactuators , rotork , contactor assembly -23a , ope/stop/close knob (red) , torque limitswitch 1no/1 nc pot.rotork
Tender For corrigendum : procurement of spares of flowmore make pumps model hms at pump section - pump shaft astm a 276 ss410 fm5911 , key for pump half coupling en9 fm5912 , oil seal de for bearingcoverouter de nitrile rubber fm5913 , stuffing box cover 2 5 percent ni ci is 210 fg 260 fm59112 , pipe plug for stuffing box cover mi fm59113 , wearing ring for stuffing box cover astm a 743 ss ca 15 fm59114 , partition plate 2 point 5 percent ni ci is 210 fg 260 fm59124 , diffuser 2 point 5 percent ni ci is 210 fg 260 fm59127 , o ring for stage to suction and delivery casing nitrile rubber fm59128 , delivery diffuser for delivery cover 2 point 5 percent ni ci is 210 fg 260 fm59131 , balance valve cover 2 point 5 percent ni ci is 210 fg 260 fm59135 , large seating and bush bronze is 318 ltb 5 fm59136 , balance valve bronze is 318 ltb 2 fm59138 , oil seal for beraing cover inner nitrile rubber fm59141 , water slinger steel fm59144 , sleeve nut two no rh and 2 no lh thread steel fm59145 , shaft sleeve nde at balance valve cover astm a 276 ss410 h fm59146 , stay tie bolt suc cover to del cover en9 fm59149 , key for suction impellor and balance valve en9 fm59152 , key shaft for stage impellor both end round en9 fm59153 , neck bush diffuser bronze is 318 ltb 5 fm59154 , wearing ring for st stage and partition plate astm a743 ss ca15 fm59155 , shaft sleeve imp to imp astm a 276 ss410 h fm59156 , case spacer bushing for cover plate bronze is 318 ltb 5 fm59157 , water seal ring bronze is 318 ltb 2 fm59159 , split gland 2 point 5percent ni ci is 210 fg 260 fm59161 , dowel pin for gland en9 fm59162 , o ring for shaft sleeve nitrile rubber fm59163 , shaft sleeve de astm a 276 ss410 h fm59164 , cinch fitting for water seal tube ss304 fm59167 , water seal tube 1st stage ss316 flexible braided pipe fm59168 , o ring for large seating and bush nitrile rubber fm59171 , impeller double suction for first stage astm a743 ss ca 6nm fm59118 , impeller single suction for second stage astm a743 ss ca 6nm fm59129
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above