Tender For group- a anatomy digital metaphase slide scanner system co2 incubator microprocessor-controlled class ii a2 type bio-safety cabinet cyclomixture weighing machine (electronic analytical and precision balances) water bath fully automated autoclave large centrifuge machine mini centrifuge machine laboratory refrigerator (cold cabinet) (4 to 10 degree c) -20 (minus twenty) degree c freezer microvolume spectrophotometer gel documentation system digital vortex mixer gradient pcr machine single channel electronic pipettes ph meter slide warning plate
Tender For supply and installation of laboratory equipments for bansberia 15 mgd wtp under bansberia municipality. - ph 700 meter,ph 700 meter with glass body open pore ph electrode, atc probe, integral electrode holder & 100/240 vac adapter and with 4, 7 ,10 480ml colored calibration buffer solution,range: -2 to 16, turbidity meter,waterproof tn-100 handheld turbidity meter with set of 4 calibration standards (800, 100, 20.0 & 0.02 ntu), set of sample vials, lint-free cloth, silicone oil, batteries, and hard carrying case,range:- 0 to 2000 ntu, conductivity meter,700 conductivity meter up to 5-point push button calibration, nan-volatile memory that holds up to 100 data points, and integral electrode holder and electrode. along with 1413 calibration solution,range:-0-2000 s/cm, lab weighing machine/ analytical balance,microprocessor based analytical balance, 220 gm capacity, 0.1 mg readability with internal calibration facility, air-shield, ss pan, lcd display, under hook facility, piece counting facility, lq oq pq certificates with internal calibration facility, air-shield,range:-0.1mg to 220 gm, chloroscope test kit ,range 0 05-5 ppm, 500 tests, range:-0.05-5 ppm
Tender For corrigendum : supply of brass sieve set of size 10 mm, 6.3 mm or 5.0 mm, 5.6 mm, 4.75 mm, 4 mm, 1 mm, 0.5 mm& 0.106 mm, for sieve analysis of misc. consumables like hddrm, dolomite, graphite powder etc. . the sieves should be of brass frame, of 200 mm diameter and 50 mm height., should meet the requirement of is- 410 part 1. the calibration certificate for size conformity to be obtained from a nabl approved laboratory with scope for the same. sieves should be of minimum 0.6 mm thickness gauge, and a minimum weight of 320 gms each. brass sieves should be without any joint machine made, uniformly fabricated with ss cloth, individually packed in printed cardboard boxes. warranty-1 year. the whole sieve set will be rejected even if a single sieve is not meeting the above requirement. if any sieve is damaged within warranty period, the supplier has to replace the same, on no payment basis. [ warranty period: 12 months after the date of delivery ] ]
Tender For corrigendum : supply of brass sieve set of size astm 8, 10, 12, 14, 16, pan with lid (lid should be with ring and not head)., for steel shots sieve analysis. the sieves should be of brass frame, of 200 mm diameter and 50 mmheight., should meet the requirement of is- 410 part 1. the calibration certificate for size conformity to be obtained from a nabl approved laboratory with scope for the same. sieves should be of minimum 0.6 mmthickness gauge, and a minimum weight of 320 gms each. brass sieves should be without any joint machine made, uniformly fabricated with ss cloth, individually packed in printed cardboard boxes. warranty-1 year. the whole sieve set will be rejected even if a single sieve is not meeting the above requirement. if any sieve is damaged within warranty period, the supplier has to replace the same, on no payment basis. [ warranty period: 12 months after the date of delivery ] ]
Tender For supply of brass sieve set of size astm 30. 40, 50, 70, 100, 140, 200, 270 & pan with lid (lid should be with ring and not head)., for sand sieve analysis. the sieves should be of brass frame, of 200 mm diameter and 50 mm height., should meet the requirement of is- 410 part 1. the calibration certificate for size conformity to be obtained from a nabl approved laboratory with scope for the same. sieves should be of minimum 0.6 mm thickness gauge, and a minimum weight of 320 gms each. brass sieves should be without any joint machine made, uniformly fabricated with ss cloth, individually packed in printed cardboard boxes . warranty-1 year. the whole sieve set will be rejected even if a single sieve is not meeting the above requirement. if any sieve is damaged within warranty period, the supplier has to replace the same, on no payment basis. [ warranty period: 12 months after the date of delivery ] ]
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine and power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura
Tender For establishment of material testing laboratory under o/o the agm(c) design and projects aegcl kahilipara - civil works, compression testing machine (2000kn) with digital reading, automatic pace control with all attachment for testing concrete cube & bricks conforming to indian standards (is: 516, is: 14858) and can also be supplied as per british standards (bs: 1881), astm c-39 with calibration certificate. it should be typically calibrated to class 1 accuracy ( 1%); featuring a robust, fully welded loading unit and hardened, ground, and polished platens, often with a self-aligning upper platen; with display type as pc-controlled with software. it should have pace rate of full three-term pid feedback control with fully automated data acquisition, storage, and analysis. the operation should be fully automated, stress & strain controlled loading., aggregate impact test, crushing value apparatus with hammer weight of 13.75 kg 0.25 kg (or 14 kg 0.5 kg), height of free fall of 380 mm 5 mm, impact cup (mould) inner diameter of 102 mm 0.25 mm and impact cup depth of 50 mm 0.25 mm as per is 2386 (part iv), bs 812-112. automation grade often semi-automatic with a digital counter. display type digital for the blow counter; sometimes includes a digital gauge for other measurements. overall weight (approx.) should be of 45 kg to 60 kg (total machine mass). standards compliance conforms to international standards like is: 2386 (part iv), bs 812-112, etc. , sieves: (40, 20, 10, 4.75, 2.36, 1. 18) mm with lid and pan and (0.6, 0.3, 0. 15, 0.075) with lid and pan (all 200mm diameter size) metal : gi, weighing balance-30kg (accuracy-1gm)., weighing balance-5kg (accuracy-0.1gm)., hot air oven with double walled design, thick glass wool insulation to prevent heat loss, micro processor based auto tune pid digital temp controller cum indicators and 230 volt 50hz single phase ac supply, heavy duty stainless steel lock, indoor hinge and sample placement trays, temp range should be 50 degree c 250 degree c with temp accuracy 0.5 degree c. it should have digital led display of size 45 cm x 45 cm x 45 cm (inner)., cube mould (cast iron) of size 150mmx150mmx150mm, isi marked as per is:10086. weight of the mould will be about 13.5 kg, strictly as per bis specifications and within required tolerance., slump cone test apparatus-(isi marked)-with tamping rod (complete set ) as per is: 7320 and is: 1199 part 2, consisting of slump cone, base plate and graduated tamping rod - made of stainless steel., proctor test apparatus with all accessories as per is: 2720 part 8 and is: 10074(1982), complete with base plate and collar., measuring cylinder-borosilicate (1 complete set ) glass of sizes 100 ml, 250 ml, 500 ml and 1000 ml., field density test app-core cutter method ( complete set) complete with core cutter of 100 mm dia x 130 mm long with chromium plating, dolly for 100 mm dia core cutter, and rammer with steel rod as per is : 2720, rebound hammer digital (original/silver schmidt type n) with calibration certificate as per is 516 part 5, sec 4 with impact energy of 2.207 nm (1.63 ft-lbf), concrete strength range of 10 100 mpa (1450 14500 psi) and weight of 570 g (1.3 lb) with display as graphic lcd (e.g., 17x71 pixels) or analog/digital and battery life: >5000 impacts., ultrasonic pulse velocity test apparatus (proceq, acoustic control systems, vedantrik technologies) with calibration certificate and frequency range of 24 500 khz (nominal transducer); measurement resolution of 0.1 s (microseconds); pulse voltage ranging from 125 v to 500 v (adjustable); receiver gain of 1x, 10x, 100x, auto, up to 1000x (lab+ model); pulse shape as square wave; measurement modes as pulse velocity, surface velocity, e-modulus, compressive strength correlation, crack depth; memory which stores >500 measured values; display should be 79x21 mm passive matrix oled; connectivity through usb for pc connection; software: pundit link for analysis and export. standards compliance
Tender For notice inviting limited tendernotice no: 01/elect./2026/ 706 date:- 10.06.2026tools & equipments of –electrician trade- heavy duty screwdriver insulated , electrician screwdriver thin stem insulated handle, , knife double bladed electrician, , chisel firmer with wooden handle, , grease gun, , (a) crimping tool, , wire cutter and stripper, , hacksaw frame, , tweezers, , drill hand brace, , plane cutters, , smoothing cutters, , file flat rough, , file flat bastard, , file rasp, half round, , the soldering gun, , contactor & auxiliary contacts (rm), , contactor & auxiliary contacts. (rm), , pin type, shackle type, egg type & suspension type insulators including hardware fitting, , portable electric drill machine, , load bank (lamp/heater type), , brake test arrangement with two spring balance rating, , laboratory type induction coil, , series test lamp (rm), , knife switch dpdt fitted with fuse terminals (rm), , knife switch tpdt fitted with fuse terminals (rm), , miniature circuit breaker (rm), , earth plate (rm), , earth electrode (rm), , elcb and rccb (rm), , fuses (rm), , rheostat (sliding type), , capacitors (rm), , various electronic components (rm), , various lamps (rm), , plug socket piano switch lamp, , holder (rm), , cables:, , twisted pair, , non-metallic sheathed cable, , underground feeder cable, , ribbon cable, , metallic sheathed cable multi-, , conductor cable coaxial cable, , direct-buried cable (rm), , rubber mat (rm), , electrician helmet, , rcc pole with accessories (ms angle iron, 'c' clamp, stay insulator etc.) and materials, , quipment, , ohm meter; series type & shunt type, portable box type, , digital multi meter, , a.c. voltmeter m.i. analog, portable box type housed in bakelite case, , milli voltmeter centre zero analog, portable box type housed in bakelite case, , ammeter mc analog, portable box type housed in bakelite case, , ac ammeter mi, analog, portable box type housed in bakelite case, , weight wattmeter analog, , (b) frequency meter (digital), , magnetic flux meter, , tachometer, , tong tester / clamp meter, , megger, , single phase variable auto transformer, , growler, , ac starters: :- -, , f. star delta starter soft starter, , g. auto transformer type, , oscilloscope dual trace, , function generator, , discrete component trainer, , linear i.c. trainer, , digital i.c. trainer, , domestic appliances -, , g. mixture & grinder, , h. washing machine semi-automatic, , i. motor pump set, , oil testing kit, , battery charger, , current transformer, , potential transformer, , 1 5 or 17 computer or latest version, , d.c. shunt generator with control panel, , motor-generator (ac to dc) with control panel, , d.c. compound generator with control panel including fitted rheostat, voltmeter, ammeter and breaker, , dc series motor coupled with spring balance load with control pannel, , dc shunt motor with control pannel, , dc shunt motor with control pannel, , dc compound motor with starter and switch with control pannel, , motor generator(dc to ac) set consisting of - shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed, , plate, fixing bolts, foundation bolts and flexible coupling., , ac squirrel cage motor with star delta starter and triple pole iron clad switch fuse with mechanical load., , ac phase-wound slip ring motor with starter switch, , universal motor with starter/switch, , synchronous motor with accessories like starter, excitation arrangements., , thyristor /igbt controlled d.c., , motor drive with tacho-generator feedback arrangement, , thyristor/igbt controlled a.c. motor drive with, , single phase transformer, core type, air cooled, , three phase transformer, shell type oil cooled with delta/ star, , electrical machine trainer -, , diesel generator set with changeover switch, ov