Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For procurement of some consumable items - disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable medical grade non toxic and dehp free tubing with 200 micron filter clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing efficient roller control for better flow control molded bulb type injection site for extra medication approximately 20 drops, l ml dw sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. should be single line monitoring dome. should be measure invasive pressure., digital foetal doppler, eye drape sheet size: 80 x 75 cm - 90 x 75 cm adhesive area: 9 x 7 cm with 6 eye lid holders drainage pouch of transparent pe film eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,there should be a string each at all four, flexible annuloplasty ring - assorted sizes, complete
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,9cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels up to and including 5mm in diameter, with ergonomic symmetrical finger ring grip-focus 9, hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,17cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels upto and including 5mm in diameter, with ergonomic symmetrical finger ring grip- focus 17, double wall resuscitator with peep valve in paediatricsit should be fully autoclavable double wall with hand strapit should be supplied with autoclavable reservoir bag it should have a singleshutter valve system made of silicone rubberit should have easy attachment of peep valve for peadiatricit should have provision to attach manometer for paediatrics ambu bagbag volume: mark iv baby (300 ml)weight: baby (190 g)it should be us-fda, ce & iso certified, ultrasorbs ap disposable drypads,dry pad for moisture management, 58.4x90cm, with breathable layer, super absorbent core, aqua shield film and air permeable back sheet, absorbency of 1800- 2300gm, usfda/ce/biscompliant, iso13485 compliant, volumetric incentive spirometer (adult) volumetric incentive spirometer (adult) 4000 ml with handle. volume measurement must be compact comfortable designed to accommodate large inspired volumes. must have good-better-best flow window & advanced, low work-of-breathing design.particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients.expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k &ce certification., neonatal high flow cannula having 8 litreflow. it can also be used for hfnc + nippv/cpap. should have a soft tip., pur-xro catheter 20 cm, 28g/1fr picc line with stylet, splitting needle with securing wings with 8cm extension tubing ( flow rate 0.7ml/min)., pur-xro catheter 30 cm, 24g/2fr picc line with split cannula and 10cm extension tubing over catheter (flow rate 4.5ml/min)., silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade long term double lumen dialysis catheter size 15 fr x 23 cmusfda certification, "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100 ml drop size of approx 60 drops per ml injection port,latexfree, for intermittent medication. floating auto shut off valve (latex free) in burette. soft and kink resistant pvc tubing. roller controller for flow control tube length 150 cm 23g needle as per iso 8536-5", "plaster of paris bandages 15cm x 2.7mts / roll testing parameter should befollowed as per bp standard", urine collecting bag, disposable 2000 ml transparent sh
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - connecting cable for ultrasonic harmonic scalpel for open energy with focus plus shear- hp blue, synthetic oxidised re- generated cellulose double layered with peg and trilysine size 5*10cm or size 5-7 x 7-11 cm or size 4x 8 inch, sterile disposable perfusion set with airway and needle (adult use) for gravity feed only sharp and easy piercing spike with air vent transparent and flexible drip chamber 150 cm long smooth kink resistant tubing self sealing latex bulb which will also act as an port for extra medication efficient roller clamp to control and adjust the fluid rate 21 g needle as per is 12655 -4 standard
Tender For catching stray dogs in the telhara municipal council area and bringing them to the abc center and after capturing stray dogs providing pre surgical care (medication and feeding) performing sterilization surgery on them and administering rabies vacc