Get complete information related to latest Bilirubin Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bilirubin Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bilirubin Kit Tenders.
Tender For rate contract consumables used in the transfusion medicine - rate contract consumables used in the transfusion medicine - acd bag, blood bag for blood bank common specification- (1)automated component separation devices (one main and one back up) compatible with the bags should be provided by the firm free of cost for processing. (2)manufacturer must comply with iso 9001, iso 13485 and european ce or us-fda, current cdsco medical device registration and provide proof of the same, umbilical cord blood bag, transfer blood bag adult, transfer blood bag pediatric, single blood collection bag (no satellite bag), single blood collection bag (no satellite bag), penta blood bag, cryopreservation bags common specification- (1) compliant with aabb standard for integral segments cryopreserved with product, (2) two separable compartments to allow for a 4:1 division of contents. (3) compatible with liquid nitrogen (ln2) storage. (4) three-dimensional bag design to allow homogenous, controlled freezing rate. (5) compatible with dmso/dextran and liquid nitrogen storage. (6) compatible with the cell wash/infusion bag set. (7) bag sold separately for connection to other processing sets. (8) it should be indivisualy wraped to prevent wastages, transfer bag with leukodepletion filter, blood irradiation indicator (gamma ray irradiation indicator
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cms (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 20 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014., suction catheter, sterile. size: fg 22 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye. colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as p