Get complete information related to latest Billing Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Billing Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Billing Machine Tenders.
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For supply, installation and commissioning of academic lab equipments with 1 year onsite warranty - sr4 spectrometer with high speed spectral acquisition with advanced singnal-to-noise performance, replaceable slit 10 m, high power tungsten halogen source, 360-2000 nm, -10,000 hrs, 2800 k, with 20w output, square one cuvette holder, universal quartz cuvette, 10mm path, 3.5ml 2 nos, quartz optical fiber 400um and 200um, vis/nir, premium 400 um reflection probe, uv/vis, 2 m wavelength range: 300nm - 1.1 m, diffuse reflectance standard, ptfe diffusing material: ptfe reflectivity: >98% (250-1500 nm)>95% (250-2200 nm), reflection probe holder is anodized aluminum platform for measurements at 45 and 90 to the surface, oceanview spectroscopy software with graphical user interface; 1 license with desirable control options
Tender For tender for supply of laboratory equipments andinstruments - machinery & equipment, hplc module pump(quaternary gradient) high precision dual plunger design. system designed to work in micro , semi-micro analytical to semi prep scale high speed double micro plunger in parallel pump with automatic pulsation correction mechanism achieving pulse free solvent delivery forced check valve designed for excellent solvent delivery control flow raterange:0.0001ml to 10.0ml/min each pump flow rate resolution of 3nl/step increment built in self diagnostic, auto purge function flow precision is less than 0.06% rsd flow rate accuracy: 1% concentration accuracy 0.5%washing kitgradient mixer,reservoir trayquaternary gradient unitdgu-20a5r bkl degassing unitmanual injector: rheodyne injector with 20 ul loop & mounting plate 25ul hamilton syringepda detectorwavelength 190 800 nm, channel 512, drift smaller than 0.5x10-3 au/hour, noise smaller than 0.6x10-5 au. wavelength accuracy should be 1 nm, linearity: 2.0au or more. a deuterium lamp [d2] and a tungsten lamp [w] should be available as light source a conventional hplc flow cell [12 l volume, 10 mm cell path length]. lamp replacement: front access, lamp life time : 2000 hours (d2 lamp)controller alite system controller, solvent bottles with cap 5/pkt, chromatographic software