Web Analytics Made Easy - StatCounter

Biometric Reader Repair Tenders

Get complete information related to latest Biometric Reader Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Biometric Reader Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Biometric Reader Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42901834 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t

CTN :42922643 Due date: 10 Dec, 202510 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode

Central Government/Public Sector

CTN :42567224 Due date: 06 Dec, 202506 Dec, 2025 2.50 Crore
Tender For corrigendum : tender for supply of supply , installation , testing and commissioning of modular key locking management system (mkms) , comprehensive annual maintenance contract (camc) for mkms for 2 years after completion of 1 year warranty period. , supply , installation , testing and commissioning of real time viewing system (rtvs) , comprehensive annual maintenance contract (camc) of rtvs for 2 years after completion of 1 year warranty period. , supply , installation , testing and commissioning of non-linear junction detector (nljd) , comprehensive annual maintenance contract (camc) of nljd for 2 years after completion of 1 year warranty period. , supply , installation , testing and commissioning of under vehicle scanning system (uvss) , comprehensive annual maintenance contract (camc) of uvss for 2 years after completion of 1 year warranty period.

CTN :42904754 Due date: 19 Dec, 202519 Dec, 2025 19.03 Crore
Tender For automation works for existing water supply system for kharghar, taloja,kamothe node and integrated command and centralized control room with hardware and software for real time data management system for cidco administrative nodes, navi mumbai.(2nd)

Central Government/Public Sector

CTN :42865522 Due date: 04 Dec, 202504 Dec, 2025 12.00 Lacs
Tender For nit for concession to supply, install, test, commission and operate automated vehicle parking management system, collection of parking fees and excess time fees rights at vijayawada airport.

Central Government/Public Sector

CTN :42844867 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For specifications for supply, installation, testing and commissioning for development of a web based broadcast air time management, scheduling and billing software for doodarshan with the provision of linkage of common functionalities with akashvani bats system

State Government

CTN :42756383 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of biomechanical equipments - nord board, it should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connectivity through usb (wired) bluetooth low energy (ble) for ipad & iphone i.e. (wireless connectivity) should provide 4 years warranty on hardware,should be provided with latest upgradable software and free software updates. should have software available in mobile & laptop (desktop) application with cloud analytics platform applications. should have ability to collect data both local i.e. laptop and on ios devices. local software:- for data collection & data analysis locally. cloud software:- for athlete data management and analysis. local (desktop /laptop) software should be compatible with windows 10 desktop applicationios 13 or later application (ipad & iphone). should have ability to collect data of over 10000 athletes or more to choose with simple name search / grouping them. cloud analytics platform for analysis. software (application) must give real time feedback of testing. license must be valid for 4years. cloud software: - should automatically sync all data collected on local mobile and laptop application when connected to internet.o should have a dashboard to see overview of organization s athletes data and different tiles(data indicators) to see athletes within and outside threshold zones. report section:- should have port section to able to compare different groups/athletes on longitudinal data. should have ability to compare same athlete s data over the period. athletes profile:- should have functionality to enter anthropometry (i.e. upper body & lower body measurement). athletes profile should be auto sync to local application and flexibility to move across different groups or teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). should be able to setup different access to different people i.e. to physiotherapist, sports scientist and s&c trainer within the organization to secure data access.api integration:- should have open-source api code for integration into athlete management system to integrate in ams system. should have software license valid for 4years. wi-fi tablet 64gb, space grey-1year warranty (as provided by oem) - service by customer service of oem only.hsn:8471.training for installation and demonstration shall be provided at olympian balbir singh senior international hockey stadium, sector- 63, mohali, punjab., electromyography (open), the system should be supplied with minimum 16 high speed wireless emg channel with built in imu sensor. should have analog+ digital base station should have analogy output option to facilitate integration with third party hardware and software sensor should have fixed inter sensor delay of 0.5 milliseconds or less sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk sensor contacts should be made up of a metal for better contact and better-quality signal should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength sensors, sensor skin interface, cable, power adapter and accessories sensors facilitate emg and imu measurements emg data analysis software for stand-alone usage with live recording of at least 32 channels an

State Government

CTN :42756410 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of sports exercise physiology lab equipments - anaerobicergometer(upper body), suitable for anaerobic upper body test (wingate option). adjustable standard chair for optimal positioning easy to start with lighter fly wheel. the weight basket is released by a pushbutton mounted on the cover. work load range 50 watt-2400 watt. 5 khz hr system in display. should be already calibrated with correct weights weight basket (1kg) system must have 4pcs 0.1kg, 1pcs 0.5 kg, 3pcs 1kg. must include-chest belt, pc, anaerobic test software, user license, ups, power adapter, printer, hdmi cable. connectivity through rs232.international safety standards european ce/usfd approved., anaerobicergometer(lower body), an ergometer for anaerobic tests (wingate test) for lower body with unique anaerobic test software computer laptop with accessories like ups, printer of suitable configuration should be provided by the supplier. multiple bouts with fatigue index high sampling frequency (50 hz) weight basket (1 kg), the fastest way from 0 to full power start from 0 rpm with accurate power extra rigid frame calibrated with correct weights 5 khz hr system for display pc connectivity withrs232 work load range: 50-2400 w weight basket system (0.1kg 4 pc, 0.5 kg-1 pc, 1 kg- 8 pc weights) for accurate workload. extra wide floor stands, prepared for fixed installations. adjustable seat post handlebar with basket release button resistance: a) system: weight basket, b) flywheel electronic meter shows pedal turns per minute (rpm)- heart rate in beats per minute (hr)- cycling time in minutes and seconds (time)- intended cycling speed in km/ miles per hour (speed)- plus distance covered in miles (distance). international safety standards. european ce/ us fda approved., spirometer (with mip andmep testingfacility), should include validated bidirectional digital turbine flowmeter or pneumotachograph with max flow range of 16l/s should be provided with suitable software for data management, real time assessment and accurate interpretation the system should have autonomy of min 4 hours. must include rechargeable batteries, battery charger, adapters, thermal papers (if required), usb cable, user manual, single use mouthpieces (200pc), single use nosepieces (25pc), thermalprinter rolls [10pc (if required)], compatible desktop/laptop, a colored multi-function printer the compatible desktop/ laptop must meet the specifications as under windows 10 (32 bit and/or 64bit), min 2ghz cpu with ram more than 4gb, more than 500gb hdd and 4 usb ports, a fullhd display monitor, ups, keyboard, mouse the lung function tests must include fvc pre/post, svc pre/post, mvv, spo2 (optional: mip/mep) interface options: usb/ rs232/bluetooth colored display safety and quality control in compliance with international guidelines (i.e. ats, ers), handgripdynamometer, measuring range up to 100 kg minimum measuring unit: 0.1kg accuracy: 0.1kg display: lcd in 3 digits items displayed: each value and the average automatic stop approx. 1minute after the final measurement dry battery with a life of approx. 100 hrs. service, temperature range: 5 to 35 degree c, backdynamometer, measuring range up to 300 kg minimum measuring unit: 0.5kg accuracy: 0.5kg display: lcd in 4 digits displayed: each value and the average automatic stop approx.1 minute after the final measurement, dry battery and life of each cell approx.100 hrs service, temperature range: 5 to 35 degree c, sit and reach box, rust proof long lasting metal box with adjustable height will be preferred scale marked in centimeters with maximum stretching indicator slide portable, blood pressuremonitor(digital), display and measurement features- display type: lcd digital display for clear and easy reading- measurement range: typically measures blood pressure and pulse rate with accuracy. - cuff size: universal cuff size, usually fitting arm circumferences between 22-32 cm accuracy and reliability- accuracy: clinically validated for accuracy, w
 Loading, Please wait...

Connect us via What's Up